SIEMENS Compact Load Feeder DOL Starter
Add to Wishlist
Add to Wishlist
SIRIUS, COMPACT STARTER, DIRECT STARTER. 690 V, 24 V DC, 3 … 12 A, IP20, CONN. MAIN CIRCUIT: SCREW TERMINAL, CONN. CONTROL CIRCUIT: SCREW TERMINAL.
Description
SIEMENS Compact Load Feeder DOL Starter
General technical data:-
Product function | ||
● Control circuit interface to parallel wiring | No | |
Product expansion | ||
● Auxiliary switch | Yes | |
Insulation voltage | ||
● Rated value | 690 V | |
Surge voltage resistance Rated value | 6 000 V | |
Protection class IP | IP20 | |
Degree of pollution | 3 | |
Vibration resistance | f= 4 … 5.8 Hz, d= 15 mm; f= 5.8 … 500 Hz, a= 20 m/s²; 10 cycles | |
Mechanical service life (switching cycles) | ||
● of the main contacts typical | 10 000 000 | |
● of the auxiliary contacts typical | 10 000 000 | |
● of the signaling contacts typical | 10 000 000 | |
Electrical endurance (switching cycles) of the auxiliary contacts | ||
● at DC-13 at 6 A at 24 V typical | 100 000 | |
● at AC-15 at 6 A at 230 V typical | 500 000 | |
Type of assignment | continuous operation according to IEC 60947-6-2 | |
Equipment marking | ||
● acc. to DIN EN 61346-2 | Q |
Ambient conditions:
Installation altitude at height above sea level maximum | 2 000 m | |
Ambient temperature | ||
● during operation | -20 … +60 °C | |
● during storage | -55 … +80 °C | |
● during transport | -55 … +80 °C | |
Relative humidity during operation | 10 … 90 % | |
Main circuit:
Number of poles for the main current circuit | 3 | |
Adjustable response value current of the current dependent overload release | 3 … 12 A | |
The formula for making capacity limit current | 12 x Ie | |
The formula for interruption capacity limit current | 10 x Ie | |
Mechanical power output for 4-pole AC motor | ||
● at 400 V Rated value | 5.5 kW | |
● at 500 V Rated value | 5.5 kW | |
● at 690 V Rated value | 7.5 kW | |
Operating voltage | ||
● at AC-3 Rated value maximum | 690 V | |
Operating current | ||
● at AC at 400 V Rated value | 12 A | |
● at AC-43 | ||
— at 400 V Rated value | 11.5 A | |
— at 500 V Rated value | 12.4 A | |
— at 690 V Rated value | 8.9 A | |
No-load switching frequency | 3 600 1/h | |
Operating frequency | ||
● at AC-41 acc. to IEC 60947-6-2 maximum | 750 1/h | |
● at AC-43 acc. to IEC 60947-6-2 maximum | 250 1/h | |
Auxiliary circuit: Control circuit/ Control:
Type of voltage | AC | |
Holding power | ||
● for DC maximum | 2.9 W | |
Auxiliary circuit:
Number of NC contacts | ||
● for auxiliary contacts | 0 | |
Number of NO contacts | ||
● for auxiliary contacts | 0 | |
● of the instantaneous short-circuit release forsignaling contact | 0 | |
Number of CO contacts | ||
● of the current-dependent overload release for
signaling contact |
0 | |
Operating current of the auxiliary contacts at AC-12
maximum |
10 A | |
Operating current of the auxiliary contacts at DC-13 | ||
● at 250 V | 0.27 A | |