The CM is a potent, small, integrated infrared sensor that is intended for continuous temperature monitoring. If your application is sensitive to noise, it can simply replace standard contact probes with a user-scaleable 0-5V output or a J-type or K-type thermocouple output.

Category:

Description

RAYTEK Infrared Temperature Sensor RAYCMLTJ

Raytek RAYCMLTJ Infrared Temperature Sensor with RS232, Type J Output, 1m Cable, 0.75-16UNF Thread Scaleable 0-5 V, type J or K output

CM Highlights-

Wide -20°C to 500°C (-4°F to 932°F) temperature range.

Rugged IP 65 (NEMA-4) stainless steel housing.

Rugged 13:1 optics at 90% energy.

150 mSec (95%) response time.

Alarm output.

Sensor status/self diagnostic indicator LED.

RS232 digital communications for sensor set-up and monitoring.

Adjustable signal processing.

DataTemp® Multidrop software compatible.

Accessories for air purging and lens protection.

Measurement Specifications:-

Temperature Range -20ºC to 500ºC (-4ºF to 932ºF)
Accuracy (mV) ± 1.5% of reading or ± 2ºC, whichever is greater 1,2
Accuracy (t/c) ± 1.5% of reading ± 2ºC or ± 4ºC,

whichever is greater1,2,3

Spectral Response 8 to 14 microns
Repeatability (digital and voltage)

Repeatability (t/c)

± 0.5% of reading or ± 2ºC, whichever is greater

± 0.5% of reading or ± 2ºC, whichever is greater

Temperature Resolution 0.1°C
Response Time (95%) 150 mSec
Emissivity 0.10 to 1.10 (adjustable)
Transmissivity 0.10 to 1.00 (adjustable)
Signal Processing Peak hold, valley hold, variable averaging
Self-diagnostics/sensor status Normal operation, alarm, out of range, unstable, sensor fault
Bore-Sight tolerance 4 3º @ focal point

1 .Accuracy from -20 to 0ºC is ±3.5ºC (Digital and voltage), ± 5.5ºC (t/c).

2.Accuracy and resolution specifications are valid for ambient temperature 23ºC ± 5ºC, e = 0.95 and calibration geometry.

3. Accuracy measured on the 0-5 VDC output or RS232 for t/c models is ± 1.5% of reading or ± 2ºC, whichever is greater.

4.Typical values measured at focal distance.

Electrical Specifications:-

Analog Outputs Model specific Type J, Type K or scaleable 0-5V voltage output
Cable Length 1m (3.3 ft) standard

3m (9.8 ft) cables optional

Thermocouple

Output Impedance

100 ohms
Voltage Output

Minimum Load Impedance

50K ohms
Power Supply 24 VDC ±20% @ 20mA
Digital Output 5 Two-way RS232 digital output
Alarm Output 5 Transistor, 24VDC @ 20mA

5 Digital output and alarm output share a common wire. User selects either alarm output or RS232 communication via

Datatemp Multidrop software.