DWYER WATER LEAK DETECTOR SERIES WD3
By spotting water in drip pans in air handler units, beneath raised floors in data centers, or on floors near sump pumps and drains, the Series WD3 Water Leak Detectors guard equipment against water damage. Once the water has risen to a point where it spans the two conductive strips on the housing’s bottom, it is detected. Depending on the model selected, local notice of the alarm situation is provided by audio and visual alerts, and remote indication or control is provided by an internal switch to stop additional water buildup. The Model WD3-BP-D1-A is battery-powered for use in situations where power is not available. Alternatively, the water detector can be powered by either AC or DC supply voltages. By using the provided adjustable mounting bracket, the sensing height can be reduced to as little as 1/32″. The mounting bracket can be fastened to any flat surface using either the mounting screws or the connected adhesive strips.
Description
DWYER WATER LEAK DETECTOR SERIES WD3
DWYER WATER LEAK DETECTOR
FEATURES-
A local alarm state is indicated by audible and visual alerts, and a remote indication or control is provided via an internal switch to stop additional water building.With the provided adjustable mounting bracket, the sensing height can be changed to as little as 1/32″ (0.79 mm).For simple installation, a mounting bracket can be fastened to any flat surface using either the adhesive strips connected or mounting screws.
Model | Description |
---|---|
WD3-BP-D1-A | Battery powered water leak detector, SPST NO SSR, with audible alarm, adjustable mounting bracket included. |
WD3-LP-D2 | Line powered water leak detector with DPDT relay, 11 to 27 VAC/DC, no audible alarm, adjustable mounting bracket included. |
WD3-LP-D2-10 | Line powered water leak detector with DPDT relay, 11 to 27 VAC/DC, no audible alarm, 10′ prewired cable. |
WD3-LP-D2-26 | Line powered water leak detector with DPDT relay, 11 to 27 VAC/DC, no audible alarm, 26′ prewired cable. |
WD3-LP-D2-30 | Line powered water leak detector with DPDT relay, 11 to 27 VAC/DC, no audible alarm, 30′ prewired cable. |
WD3-LP-D2-A | Line powered water leak detector with DPDT relay, 11 to 27 VAC/DC, with audible alarm, adjustable mounting bracket included. |
DWYER WATER LEAK DETECTOR SERIES WD3
SPECIFICATIONS-
♦ Service:-Water or conductive fluids.
♦ Minimum Sensing Gap:-1/32″.
♦ Switch Type:-Battery powered models: SPST NO SSR; External powered models: DPDT relay.
♦ Electrical Ratings:Battery powered model: Pilot duty rating 250 mA @ 24 VDC; External powered models: 1 A @ 24 VAC/DC.
♦ Audible Alarm:-At least 85 dB @ 1′ distance (depends on model).
♦ Visual Alarm:-Red LED for water level; Yellow LED for low battery (battery powered models only); Green LED for power condition (external powered models only).
♦ Temperature Limits:-32 to 122°F (0 to 50°C).
♦ Power Requirements:-Battery powered model: 3V CR2450 lithium metal battery, installed functional, user replaceable; External powered models: 24 VAC (±10%) or 11 to 27 VDC.
♦ Power Consumption:-Battery powered model: 0.9 mA steady state / 3.0 mA during alarm condition; External powered models: 30 mA steady state / 85 mA during alarm condition.
♦ Battery Life:-5 years steady state / 48 hours during alarm condition.
♦ Electrical Connections:-4.9′ (1.5 m), 22 AWG, PVC, UL plenum rated cable.
♦ Enclosure Material:-ABS and polycarbonate with flammability classification UL 94 V-0.
♦ Enclosure Rating:-Audible alarm models: Watertight up to 3/4 of the body height; Non-audible alarm models: NEMA 6P (IP68) submersible.
♦ Weight:-4.85 oz (137.5 g).
♦ Agency Approvals:-CE, RoHS.