YASKAWA AC DRIVE J1000
Add to Wishlist
Add to Wishlist
Compact V/f Control Drive
Models:-
200 V Class, Three-Phase Input: 0.1 to 5.5 kW.
200 V Class, Single-Phase Input: 0.1 to 2.2 kW.
400 V Class, Three-Phase Input: 0.2 to 5.5 kW.
Description
YASKAWA AC DRIVE J1000
Compact V/f Control Drive
Drive Specifications
Note: For optimum performance life of the drive, install the drive in an environment that meets the environmental conditions.
Item | Specification | |
Control Characteristics | Control Method | V/f Control |
Frequency Control Range | 0.01 to 400 Hz | |
Frequency Accuracy | Digital input: within ±0.01% of the max output frequency (-10 to +50 °C) Analog input: within ±0.5% of the max output frequency (25 °C ±10 °C) | |
Frequency SettingResolution | Digital inputs: 0.01 HzAnalog inputs: 1/1000 of maximum output frequency | |
Output FrequencyCalculation Resolution | 1/220 x Maximum output frequency (E1–04) | |
Frequency Setting Signal | Main frequency reference: 0 to +10 Vdc (20 kΩ), 4 to 20 mA (250 Ω), 0 to 20 mA (250 Ω) | |
Starting Torque | 150%/3 Hz | |
Speed Control Range | 1: 20~40 | |
Accel/Decel Time | 0.00 to 6000.0 s (allows four separate settings for accel and decel) | |
Braking Torque | Instantaneous Average Decel Torque <1> : 0.1/0.2 kW: over 150%, 0.4/0.75 kW: over 100%, 1.5 kW: over 50%, 2.2 kW and above: over 20%Continuous Regen Torque: 20%,125% with a Braking Resistor Unit <2> : (10% ED) 10 s with an internal braking resistor. | |
V/f Characteristics | User-set, programmable. | |
Functions | • Momentary Power Loss Ride-Thru• Speed Search• Multi-Step Speed (9 steps max)• Accel/Decel Time Switch• S-Curve Accel/Decel• 2-Wire/3-Wire Sequence• Cooling Fan ON/OFF• Slip Compensation• Torque Compensation• Jump Frequencies (reference dead band)• Frequency Reference Upper/Lower Limit• DC Injection Braking (start and stop)• Overexcitation Braking• Fault Reset | |
Protection Functions | Motor Protection | Motor overheat protection via output current sensor |
Overcurrent Protection | Drives stops when output exceeds 200% of the rated current (Heavy Duty) | |
Overload Protection | A stop command will be entered after operating at 150% for 60 s (Heavy Duty) <3> | |
Overvoltage Specification | 200 V class: Stops when DC bus voltage exceeds approximately 410 V400 V class: Stops when DC bus voltage exceeds approximately 820 V | |
Low Voltage Protection | Drive stops when DC bus voltage falls below the levels indicated:190 V (3-phase 200 V), 160 V (single-phase 200 V), 380 V (3-phase 400 V), 350 V (3-phase 380 V) | |
Momentary Power Loss Ride-Thru | Stops after 15 ms | |
Heatsink OverheatProtection | Protected by thermistor | |
Braking Resistor OverheatProtection | Overheat input signal for braking resistor (Optional ERF-type, 3% ED) | |
Stall Prevention | During acceleration and during run: Separate settings for each type of stall prevention determine the current level at which stall prevention is triggered.During deceleration: Select, enable/disable. | |
Cooling Fan FailureProtection | Circuit protection (“fan-lock” sensor) | |
Ground Fault Protection | Electronic circuit protection <4> | |
DC Bus Charge LED | Remains lit until DC bus voltage falls below 50 V |
Additional information
Brand | YASKAWA |
---|