LS PLC Master K 120S CPU K7M-DR20U
- MASTER-K80S/120S
- Compact and high-function block type.
- Program capacity: 7k steps/10k steps.
- Various main and expansion modules.
- High-function built-in functions: Input filter, Positioning, PID,
HSC, built-in Cnet. - Diverse special/network modules
On-line edit support.
Description
LS PLC Master K 120S CPU K7M-DR20U
■Features-
High-performance and various block type.
♦ Economic type: 10/14/20/30 points.
(10/14 points: 2points built-in Analog Timer).
♦ Standard type: 20/30/40/60 points.
♦ Various expansion modules: input, output, mixed modules..
♦P area extended for SMART I/O application (P000~P63F).
♦ High-speed processing speed: 0.1㎲/step (standard type).
♦ Battery-less backup.
– Program backup: EEPROM backup while online editing.
– Data backup: Super capacitor.
♦ Various input handing: Input filter, pulse catch.
Enhanced communication functions-
♦ Built-in RS-232C (Ch0) and RS-485 (Ch1) support *1).
♦ Transmitting data monitoring support: KGLWIN.
♦ Various option modules-
– Cnet (RS-232C, RS-422) Fnet/Rnet (master module).
– Profibus-DP/DeviceNet (slave module).
Specifications:-
Item
|
|
Remark | ||||||||||||||||||||||||||||||
Operation method | Cyclic execution of a stored program, Time-driven interrupt, Process-driven interrupt | |||||||||||||||||||||||||||||||
I/O control method | Refresh method, Direct method by common | |||||||||||||||||||||||||||||||
|
Instruction list, Ladder diagram | |||||||||||||||||||||||||||||||
|
Basic: 30, Application: 269 | |||||||||||||||||||||||||||||||
Processing speed | 0.1~0.9㎲/step | |||||||||||||||||||||||||||||||
0.1~0.9㎲/step | ||||||||||||||||||||||||||||||||
|
|
|||||||||||||||||||||||||||||||
Data area
|
|
|
|
|||||||||||||||||||||||||||||
Operation mode | Run, Stop, Pause | |||||||||||||||||||||||||||||||
Self-diagnostic function | Scan time, memory, I/O, and power supply error detection | |||||||||||||||||||||||||||||||
Data back-up method | Program: EEPROM, Data: Super-capacitor | |||||||||||||||||||||||||||||||
Max. expansion stage | Up to 2 stages (external memory or RTC module can be connected as 3rd expansion) | |||||||||||||||||||||||||||||||
Built-in function
|
Cnet I/F function | Dedicated protocol, MODBUS protocol, User-defined protocol, No protocol | RS-485 only in | |||||||||||||||||||||||||||||
HSC |
Speed | RS-232C: 1 port | K7M-DR(10/14)UE | |||||||||||||||||||||||||||||
Mode | 4-different counter modes: 1-phase operation mode, 2-phase CW/CCW mode
1-phase pulse+direction mode, 2-phase multiplication mode |
|||||||||||||||||||||||||||||||
Additional function | Internal/external preset, Latch counter, RPM, Comparison output | |||||||||||||||||||||||||||||||
|
|
|||||||||||||||||||||||||||||||
External interrupt | 50㎲ (4 points) | |||||||||||||||||||||||||||||||
Input filter | 0, 1, 2, 5, 10, 20, 50, 100, 200, 500, 1000ms (Default: 10ms) | |||||||||||||||||||||||||||||||
* In case of K7M-DR10UE (/DC) and K7M-DR14UE (/DC), you are not able to use built-in RS-232C/485 at the same time.
When you want to use built-in Cnet, you have to select either built-in RS-232C (Cnet dip switch on) or built-in RS-485 (Cnet dip switch off). In these two types, if you are going to use Cnet I/F module, you cannot use any built-in Cnet channels while built-in Cnet dip switch is on.
* In other economic types, you are not supposed to use built-in RS-232C and Cnet I/F module at the same time. When you turn off Cnet dip switch, you can use Cnet I/F module.