JUMO Digital Indicator di 308

Add to Wishlist
Add to Wishlist

The JUMO di 308 signaling device shows standard signals in “simple text” as well as temperatures in °C or °F. The fundamental device is pre-configured with a voltage supply for two-wire transmitters, 1 analog input, 2 binary inputs, 2 relay outputs, and 2 logic outputs.

Description

JUMO Digital indicator di 308

The digital indicator shows temperatures in °C or °F and standard signals in plain text.

  • Inputs/outputs- The standard instrument is equipped with an analog input, two binary inputs, two relay outputs, two logic outputs as well as a voltage supply for two-wire transmitters.
  • Optional modules-Three extension slots can be equipped with additionalinputs and outputs as well as interfaces.
  • Displays-The high-contrast, multi-colour LCD display for process value/text and operator prompting contains a five-digit 7-segment display (showing the value or
    parameter setting) and an eight-digit 16-segment display with colour change (value, parameter name, channel name, process/alarm text as max. 24 character ticker or pseudo bargraph). Four additional switch position indicators are available for binary outputs (relay or logic).
  • Operation The instrument is operated and configured by four keys; an optional setup program for a PC is available. The user-friendly setup program provides additional configuration possibilities (e.g. math and logic functions, display texts).
  • Special functions-The instrument offers 4 configurable limit comparators and an optional math and logic module (two virtual channels).Extensive binary functions are available for the assignment of functions to the signals of limit comparators, logic and binary inputs.
  • Probes- 10 types of probes (RTD temperature probe, thermocouple, resistance transmitter, standard signals) and more than 20 linearisations are available for analog input configuration. Customer-specific linearisation with 10 interpolation points or by the entry of the polynomial coefficients is possible.
  • Interface and electrical connection-An optional interface (RS422/485 or PROFIBUS-DP) can be used for integration of the instrument in a data network.
    The electrical connection is made at the back of the instrument by means of screw terminals.

JUMO Digital indicator di 308

Technical Data:-

Thermocouple input

1 incl. measuring accuracy at the cold junction

2 in the range from 300…1820°C

Designation Measuring range Measuring

accuracy1,3

Ambient

temperature

error

Fe-Con „L“

Fe-Con „J“

Cu-Con „U“

Cu-Con „T“

NiCr-Ni „K“

NiCr-Con „E“

NiCrSi-NiSi „N“

Pt10Rh-Pt „S“

Pt13Rh-Pt „R“

Pt30Rh-Pt6Rh „B“

W5Re-W26Re „C“

W3Re-W25Re „D“

W3Re-W26Re

Chromel-Copel

EN 60584

EN 60584

EN 60584

EN 60584

EN 60584

EN 60584

EN 60584

EN 60584

GOST R

8.585-2001

-200 to +900°C

-200 to +1200°C

-200 to +600°C

-200 to +400°C

-200 to +1372°C

-200 to +1000°C

-100 to +1300°C

0 to +1768°C

0 to +1768°C

0 to +1820°C

0 to +2320°C

0 to +2495°C

0 to +2400°C

-200 to +800°C

≤ 0.25%

≤ 0.25%

≤ 0.25%

≤ 0.25%

≤ 0.25%

≤ 0.25%

≤ 0.25%

≤ 0.25%

≤ 0.25%

≤ 0.25% 2

≤ 0.25%

≤ 0.25%

≤ 0.25%

≤ 0.25%

100ppm/K

100ppm/K

100ppm/K

100ppm/K

100ppm/K

100ppm/K

100ppm/K

100ppm/K

100ppm/K

100ppm/K

100ppm/K

100ppm/K

100ppm/K

100ppm/K

Cold junction Pt 100 internal

1 incl. measuring accuracy at the cold junction.

2 in the range from 300…1820°C.

RTD temperature probe input-

3 The accuracy refers to the max. measurement range span. The linearization accuracy is

 

reduced with short spans.

 

Designation Connection

circuit

Measuring

range

Measuring

accuracy3

3-/4-

wire

2-

wire

Ambient

temperature error

Pt100 DIN EN

60751

2-wire/3-wire/

4-wire

-200 to +850°C 0.05% 0.4% 50ppm/K
Pt500 DIN EN

60751

2-wire/3-wire/

4-wire

-200 to +850°C 0.2% 0.4% 100ppm/K
Pt1000 DIN EN

60751

2-wire/3-wire/

4-wire

-200 to +850°C 0.1% 0.2% 50ppm/K
Pt50 GOST

6651-94

2-wire/3-wire/

4-wire

-200 to +850°C 0.1% 0.8% 50ppm/K
Pt100 GOST

6651-94

2-wire/3-wire/

4-wire

-200 to +850°C 0.05% 0.4% 50ppm/K
Cu50 GOST

6651-94

2-wire/3-wire/

4-wire

-50 to +200°C 0.2% 1.6% 50ppm/K
Cu100 GOST

6651-94

2-wire/3-wire/

4-wire

-50 to +200°C 0.1% 0.8% 50ppm/K
KTY11-6 2-wire -50 to +150°C 2.0% 50ppm/K

RTD temperature probe input (continued)-

Sensor lead

resistance

max. 30Ω per lead for 3-wire/4-wire circuit
Measuring current approx. 250µA
Lead compensation Not required for 3-wire and 4-wire circuit. For a 2-wire circuit, the

lead resistance can be compensated in the software by correcting

the actual value.

Standard signals input-

3 The accuracy refers to the max. measurement range span. The linearization accuracy is

reduced with short spans.

Designation Measuring range Measuring

accuracy3

Ambient

temperature

error

Voltage 0(2)—10V

0—1V

Input resistance RIN > 100kΩ

0.05%

0.05%

100ppm/K

100ppm/K

Current 0(4)—20mA

Voltage drop 1.5V

0.05% 100ppm/K
Resistance transmitter min. 100Ω, max. 4kΩ ± 4Ω 100ppm/K

Outputs

Relay (change-over) Contact rating Contact life 5A at 230VAC resistive load350,000 operations at rated load/750,000 operations at 1A
Relay (changeover (option))Contact ratingContact life 8A at 230VAC resistive load100,000 operations at rated load/350,000 operations at 3A
Relay (n.o. make (option)) Contact rating Contact life 3A at 230VAC resistive load350,000 operations at rated load/900,000 operations at 1A
Logic output 0/12V / 25mA max. (sum of all output currents)
Solid-state relay (option) Contact rating Protection circuitry 1A at 230V Varistor
Voltage (option) Output signals Load resistance Accuracy 0—10V / 2—10V RLoad 500Ω ≤ 0.5%
Current (option) Output signals Load resistance Accuracy 0—20mA / 4—20mA RLoad 500Ω ≤ 0.5%
Voltage supply for 2-wire transmitter electrically isolated, not stabilised 15.8—15.2V / 30—50mA (no-load voltage approx. 25V)