BENTLY NEVADA Trendmaster 200132 Pressure Transducer System

Add to Wishlist
Add to Wishlist

Trendmaster 200132 Pressure Transducer System – The 200132 sensor was designed to provide static (average) pressure measurements from general process monitoring to the Trendmaster† system. The Bently Nevada Trendmaster Pro online condition monitoring system links hundreds of permanently mounted transducers and measurement points onto a single-cable sensor network and transfers the data into  System 1 machine condition monitoring software.

  • Vibration.
  • Temperature.
  • Seal leaks.
  • Pressure.

Description

BENTLY NAVADA Trendmaster 200132 Pressure Transducer System

The Dual Pressure flexiTIM* module interfaces 2 individual pressure transducers to the Trendmaster* 2000 System and is intended for non-dynamic pressure applications.The flexiTIM module and cable interfaces with pressure transducers using a 4-pin, locking bayonet connection. Compatible transducers are standard, millivolt output type devices with an output sensitivity of 10 mV/V. This flexibility allows the dual pressure flexiTIM system to measure a wide range of pressures under a variety of operating conditions. We offer a standard transducer for use with the flexiTIM module for convenience.

Specifications:-

All specifications are at 25 °C (77 °F) unless otherwise specified.

Electrical-

Full Scale Range The pressure transducer sets the Trendmaster full-scale pressure range. The user enters the transducer’s full-scale range into the Trendmaster software.
Accuracy ±8.5% of the transducer full-scale rating (transducer accuracy not included).
Transducer Excitation Voltage 4.98 Vdc ± 65 mVdc.
Maximum Transducer Supply Current 2.5 mA absolute maximum available over temperature.
Transducer OK Range 1 Vdc to 3 Vdc bias from transducer (nominal).
Resolution 0.025% of transducer’s full scale rating.
Transducer Bridge type meeting stated requirements.

Environmental Limits-

Operating Temperature -40 °C to +100 °C (-40 °F to +212 °F).
Humidity 100% condensing on exposed surfaces. 100% non-condensing on surfaces inside conduit.
Housing Materials Powder-coated aluminum.
Weight 554 g (20 oz) not including conduit body

Mechanical:-

Operating

Temperature

-54 °C to +121 °C (-65 °F to

+250 °F).

Compensated

Temperature

+10 °C to +93 °C (+50 °F to

+200 °F).

Connector MS3113H8-4P, 4-position male

or equivalent:

A = + Excitation

B = + Out

C = – Out

D = – Excitation

Proof Pressure 2X Full Pressure Scale.
Burst Pressure 3X Full Pressure Scale
Pressure

Fitting

1/4 – 18 NPT male.
Case Material 316 Stainless Steel.
Insulation

resistance

> 50 MΩ @ 50 VDC.

200132 Pressure Transducer

Pressure Ranges PSI SG 30, 50, 100, 300, and 500.
Sensitivity 10 mV/V ± 1%.
Zero Offset ±3mV (±6% of full scale range) at atmospheric pressure (14.7 PSI).
Absolute Accuracy ±4% over compensated temperature range.
Excitation 5 Vdc to 10 VDC (nominal).
Input Resistance > 2 K W.