Need help? Call us: 01326 708334, 01326 708335 or info@voltecbd.com
- Single-digit temperature controller with three digits.
- Sensor input: (TC: J, K, T, R, S/RTD: PT100).
- Control for ON/OFF/Auto-tuning PID.
- Only one set point.
- 12V SSR control output with a 10A relay.
- Compact size: 48 mm by 48 mm.
- Mount a panel.
- AC/DC supply voltage between 90 and 270V.
| 8BVI0014HWS0.000-1 | ACOPOSmulti inverter module, 1.9 A, AS, wall mounting | |
| 8BVI0028HWS0.000-1 | ACOPOSmulti inverter module, 3.8 A, AS, wall mounting | |
| 8BVI0055HWS0.000-1 | ACOPOSmulti inverter module, 7.6 A, AS, wall mounting | |
| 8BVI0110HWS0.000-1 | ACOPOSmulti inverter module, 15.1 A, AS, wall mounting | |
| 8BVI0220HWS0.000-1 | ACOPOSmulti inverter module, 22 A, AS, wall mounting | |
| 8BVI0330HWS0.000-1 | ACOPOSmulti inverter module, 33 A, AS, wall mounting | |
| 8BVI0440HWS0.000-1 | ACOPOSmulti inverter module, 44 A, AS, wall mounting | |
| 8BVI0660HWS0.000-1 | ACOPOSmulti inverter module, 66 A, AS, wall mounting | |
| 8BVI0660HWS0.008-1 | ACOPOSmulti inverter module, 66 A, AS, wall mounting | |
| 8BVI0880HWS0.004-1 | ACOPOSmulti inverter module, 88 A, AS, wall mounting | |
| 8BVI0880HWS0.008-1 | ACOPOSmulti inverter module, 88 A, AS, wall mounting | |
| 8BVI1650HWS0.000-1 | ACOPOSmulti inverter module, 165 A, AS, wall mounting | |
| 8BVI1650HWS0.004-1 | ACOPOSmulti inverter module, 165 A, AS, wall mounting | |
| 8BVI2000HWS0.000-1 | ACOPOSmulti inverter module, 200 A, AS, wall mounting |
- Body Material : Brass, Stainless Steel, Lead-free Brass, 316 stainless steel on request
- Media : Aggressive Liquids/Gases, Air, Inert Gas, Ammonia, Cryogenic, Fuel Oil, Hot Water, Light Oil, Liquid Propane Gas, Natural Gas, Oxygen, Steam, Vacuum, Water
- Pipe / Port Size : 1/2 "; 3/8 "; 3/4 "; 1 "; 1 1/4 "; 1 1/2 "; 2 "; 2 1/2 "
- Port Type : NPTF, G (ISO 228/1)
- Function : 2 way - 2/2 Normally Closed, 2 way - 2/2 Normally Open
- Flow : From 1.3 to 39 Kv , 1.5 to 45 Cv
- Voltage : 24 AC, 110 AC, 115 AC, 12 DC, 12 to 24 DC Voltage Ranging, 120 AC, 120 DC, 125 DC Battery Charging, 208 AC, 220 AC, 230 AC, 24 DC, 24 to 120 AC/DC Voltage Ranging, 240 AC, 240 DC - 50/60, Uncommon voltages available upon request.
- Max Differential / Max Operating Pressure: Vacuum to 24 bar, Vacuum to 350 psi
- Operating Environment : Corrosive, Hazardous, Indoor, Outdoor
Features at a Glance
- Repetition accuracy: 5 µm
- Recognition of transparent objects
- Fine light beam (0,6 mm) over entire width of fork
- Teach-in
|
Individual relays |
|||
Individual relays within the RIDERSERIES RCM
|
|||
- Programmable via e!COCKPIT
- Direct connection of WAGO's I/O modules
- 2 x ETHERNET (configurable)
- Linux 3.18 operating system with RT‐Preempt patch
- Configuration via e!COCKPIT or Web-Based Management interface
- Maintenance-free
- DN25 - DN50 PN40.
- DN65 - DN200 PN16.
- Air pressure is continuously controlled in response to an electrical signal.
- 5.0 MPa is the maximum supply pressure.
- Range of the set pressure: 0.01 to 3.0 MPa.
- 3000 L/min is the maximum flow rate [ANR].
- Fluid: Air, N2, O2, Ar.
- Wetted parts: Fluorine grease.
- Food industry
- Beverage industry
- Construction industry
- Automotive industry
- Timber industry
- 3 cable entries M 16 x 1.5.
- Thermoplastic enclosure.
- Coding level "High" according to ISO 14119.
- 52 mm x 90 mm x 30 mm.
- A long life.
- Large wiring compartment.
- High level of contact reliability with low voltages and currents.
Salzer offer limit switches in a range of different series. Each series is designed for a different application. The series are PC 100, PC 200, PC 300, PC 400, PC 600, PC 900 and PC 1500.
Salzer also have a wide range of foot switches such as compact foot switch, heavy duty foot switch, domestic foot switch, mini foot switch and meditwin.Applications:
- Manufacturing Engineering
- Plastic injection molding
- Textile
- Packaging
- Sheet metal working
- Woodwork
- Automation Technology
| Medium | Compressed Air |
|---|---|
| Operating Temperature | 5 ... 176 °F |
| Standard | VDMA 24 345 |
| Actuation | Sol/Sol |
| ISO Size | ISO #1 |
| Operation | 5/2 |
| Materials - Body | Diecast aluminium |
| Materials - Nuts/Screws | Zinc plated steel |
| Materials - Seals | Nitrile rubber |
| Certification - WEEE | WEEE |
| Classification - eClass 11 | 51030190 |
| Range | SXE |
| Series | ISO Star |
| Brand | Norgren |
- According to wenglor weproTec, there is very little mounting clearance.
- ASIC circuit technology that is innovative.
- Built-in error display.
-
Wattage :
- 75W~480W
-
Features :
- Metal case, economical models 1∅, full range input Slim size, model width: 32 ~ 85.5mm EMC EN55022 class B Assemble on industrial rail TS-35 / 7.5 or 15
I58S
Standard encoder for general industrial application - Size 58 mm - Resolution up to 10000 PPR (real) - Servo or clamp flange - High operating temperature range (optional)
| Manufacturer | Lika Electronic Srl |
|---|---|
| Description | Standard Lika encoder for general industrial application - Size 58 mm - Resolution up to 10000 PPR (real) - Servo or clamp flange - High operating temperature range (optional) |
| Item number | I58S |
| Housing-Ø (mm) | 58 |
| Shaft-Ø (mm) | 6, 8, 9.52, 10, 12 |
| max. resolution | 10000 PPR max. |
|---|---|
| Output circuit / Interface | NPN, PP, LD, Universal (PP+LD), sin/cos |
| Connection | Cable or connector output |
| Category | Industrial duty |
Technical data and features
| Technical data |
0.25 ... 45 kW |
|---|---|
| Connections |
1 AC 230 V
3 AC 400 V
3 AC 480 V
5x digital input
1x digital output
1x analog input
1x analog output
1x NO/NC relay
DC bus (400-V types)
Motor temperature monitoring |
- Magnetic – robust
- Ideal for small devices
- Wear-free
- Dimension - Ø 24 mm
- Resolution - 12 bits singleturn
- Shaft type - Max 6 mm shaft, round
- Max 5 mm shaft, with flat surface
- Magnetic – robust
- Ideal for small devices
- Wear-free
- Dimension - Ø 24 mm
- Resolution - 12 bits singleturn
- Shaft type - Max 6 mm hollow shaft, blind hole
VersaFlow Magnetic Flowmeters are highly versatile, customizable and offer precise flow measurement for conductive liquids, pastes and slurries.
| Product Family | RI58 |
| Ordering Information | RotaryEncoderRI58 |
| Fuction / Application | Incremental |
| Technology | Optical |
| Approval |
|
Mechanical
| Housing Diameter [mm] | 58 mm |
| Solid- / Hollow Shaft |
|
| Protection Rating Housing | IP40 / IP50 / IP64 / IP67 |
| Operating Temperatur [°C] | -25 ... +100 °C (depending on version) |
| Housing Option |
|
| Connection |
|
Incremental Encoder
- Versions with one or two channels.
- Alternative adaptive line driver.
- High-resolution, unbreakable code disc.
- Universal industrial plugs.
- Ingress protection NEMA 4X, IP67.
- Available with nickel- or stainless-steel-clad housing.
ECN 1100 and EQN 1100 series- Absolute rotary encoders with integral bearings.
- Stator coupling for a surface in a plane.
- Up to 0.5 mm of axial tolerance.
- hollow blind shaft.
- Positioning accuracy of down to ± 60''.
- Capability for up to 4096 revolutions in a turn.
- 115 °C is the maximum operational temperature.
- Interfaces: EnDat and DRIVE-CLiQ.
- Housing diameter ≈ 35 mm.
- Outstanding Long-Term Stability.
- 0-150 psi to 0-10000 psi Ranges (0-10 bar to 0-700 bar).
- High Proof Pressures with Completely Wetted Stainless Steel Components.
- The best price-to-performance ratio in its class for a small package size.
- Proven Thin Film Sensor Technology.
- With an adaptor with 187 Faston, 4.8 x 0.5 mm connections, flange installation is possible.
- AC or DC coil.
- mechanical indication and lockable test button.
- Cadmium-free contacts (standard version).
- Options for material contact.
- Utilized with 96 Series sockets.
- EMC suppression and coil indicator modules for the 99 Series are compatible with this.
- Accessories available.
- European patent.
- Also available in:-Type 56.32-0300 (with 2 pole normally open contact (≥ 1.5 mm gap).
- Brushless, synchronous, permanent magnet motor.
- Either a single-turn or multiple-turn digital absolute linear potentiometer.
- High synchronization is supported even at low rotational speeds by an extremely low cogging torque.
- One connecting cable serves as the supply and encoder in simple connection technology (OCP: One Cable Plug).
- Angle-adjustable rotating plug (310°).
- offering a holding brake.
Features:-
- Solenoid operating voltage optionally 24 VDC / 110 VAC / 230 VAC.
- With 2 switching contacts or with 4 switching contacts.
- LED function display for different voltage ranges.
- Mechanically locked, release by applying voltage.
- Electrically locked, locking by applying voltage.
- Measurement and control of flow up to 120 kg/h.
- Extremely high measurement accuracy and range.
- Excellent long-term stability, no need for zero-point correction.
- highly durable wet materials.
- Suitable for a wide range of liquids.
R900720175 - DIRECTIONAL SPOOL VALVE 4WE6E73-6X/EG24K4
Size 6, symbol E73, electrical with solenoid, 24 V DC
Shipped in 20 business days from Lohr, DE
R900722801 - DIRECTIONAL SPOOL VALVE 4WE6D6X/OFEG24N9K4/B30
Size 6, symbol D, electrical with solenoid, 24 V DC
Shipped in 20 business days from Lohr, DE
- The incremental HeavyDuty standard : HOG86 / POG86
- Unmatched variety, proven robustness : HOG9 / POG9
- The unrivalled benchmark : HOG10 / POG10
- The intelligent solution : HMG10P / PMG10P incremental
- SinCos output – LowHarmonics for outstanding signal quality: OGS71 ... HOGS151
- Solid shaft with EURO flange B10
- Complete portfolio of solid shaft designs
BANNER PHOTOELECTRIC SENSOR QS30 SERIES FEATURES:
- Innovative 30 mm housing design to suit almost any mounting requirement.
- High-power sensing with ranges up to 200 m.
- Available in opposed, high-power opposed, polarized and non-polarized retroreflective, diffuse, laser, fixed-field and adjustable-field and clear object sensing modes.
- Class 1 visible laser in diffuse and retroreflective models and Class 2 in diffuse models.
- Models with standard 10 to 30V dc supply voltage and bipolar NPN/PNP outputs or 24 to 250V ac/12 to 250V ac supply voltage with e/m relay output.
- Light- or dark-operate selectable or configurable, depending on model.
- IP67 or IP69K environmental rating, depending on model.
- Bright LED operating status indicators visible from 360°.
Features:
- General purpose, industrial grade transducer
- Diffused silicon sensor for high accuracy and reliability
- Rugged stainless steel construction
- Built-in pressure snubber for high pressure applications (2000 psi and above)
- Wide range of electrical connections available
Applications
- Oil pressure hydraulics
- Cranes
- Presses
- Gas metering
- HVAC
- Medical equipment
Pressure-rated inductive sensors
- Pressure-rated up to 500 bar
- High temperature-rated up to 120 °C
- Appropriate for use in explosion-protected areas
- Overall dimensions from M5 to M18
- Short and long configurations
- With and without fixed stop
Inductive standard sensors:
- Cylindrical sensors in designs from M5 to M30 and various cuboid configuration
- Variants for DC-3/4 wire, IO-Link and DC, AC and AC/DC 2 wire
- Shielded and unshielded versions
- Flush variants with ranges of up to 15 mm
- Non-flush variants with ranges of up to 30 mm
- Plug or cable connection
Technical Specification:
| Process Connection | CLEANadapt │ Tri-Clamp │ Varivent │ FLEXadapt ESF │ Thread | Without thread |
| Insertion length | 0…2000 mm (flush version available) |
| Wetted material | Stainless steel 1.4404 (AISI 316L) │ PEEK (Dependent on type ) |
| Measuring range | -200 °C …+400 °C |
| Accuracy | < ±0.1 °C/°F |
| Available versions | Head Ø18 mm │ Spacer │ Transmitter |
| Operating pressure | max. 50 bar | 10 bar (Dependent on type ) |
| Communication | 4…20 mA, IO-Link |
| 1766-L32AWA | MicroLogix 1400, 20 digital 120V ac inputs, 12 Relay outputs, 110/240V ac power | |
| 1766-L32AWAA | MicroLogix 1400, 20 digital 120V ac inputs, 12 Relay outputs, 4 Analog (12 bits) inputs, 2 Analog (12 bits) outputs, 110/240V ac power | |
| 1766-L32BWA | MicroLogix 1400, 12 digital fast 24V dc inputs, 8 digital normal 24V dc inputs, 12 relays outputs, 110/240V ac power | |
| 1766-L32BWAA | MicroLogix 1400, 12 digital fast 24V dc inputs, 8 digital normal 24V dc inputs, 12 relays outputs, 4 Analog (12 bits) inputs, 2 Analog (12 bits) outputs, 110/240V ac power | |
| 1766-L32BXB | MicroLogix 1400, 12 digital fast 24V dc inputs, 8 digital 24V dc inputs, 6 relay outputs, 3 fast 24V dc outputs, 3 normal 24V dc outputs, 24V dc power | |
| 1766-L32BXBA | MicroLogix 1400, 12 digital fast 24V dc inputs, 8 digital 24V dc inputs, 6 relay outputs, 3 fast 24V dc outputs, 3 normal 24V dc outputs, 4 Analog (12 bits) inputs, 2 Analog (12 bits) outputs, 24V dc power | |
| 1766-MM1 | Memory Module for MicroLogix 1400 |
- Rated speed :-PME120-AI/-AN – 20 to 60 s/90° .
- Operating angle:- – min 35° / max. 300° .
Narrow design:
- Space-saving housing, just 10 mm wide.
- Beam spacings between 5 and 100 mm
- 5 m operating range and measurement field lengths up to 3100 mm
Standard design
- 4 configurable inputs/outputs and IO-Link interface
- Response time of just 30 μs for very fast processes
- Lateral housing groove enables very flexible mounting
Reflection principle
- Reflection principle with operating range up to 700 mm
- Detection of small objects (e.g., 10 x 10 x 1 mm) at up to 3.5 m/s
- Readjustment when soiled, warning output for prefailure messages
Advantages:
- Models in multicolor (RGB) or white light (W) offer optimum performance for marker detection on colorfully printed or glossy films
- White light provides greater reliability in the case of contrast markers on glossy surfaces
- Multicolor (RGB) provides better performance with colorfully printed films
- Free selection of adjustment method: intuitively using removable potentiometers, quickly and precisely by means of teach buttons. Also of course remotely through teach via cable or IO-Link
- IO-Link with dual channel: for monitoring, diagnosis, easy changeover in the case of format change
- Three teach levels ensure the perfect adjustment routine for every application
- Static 2-point teach with stationary conveyor belt based on marker and background
- Dynamic 2-point teach with running conveyor belt
- Static 1-point teach detects any contrast markers in front of a homogeneous background
- Permanent signal indication through self-adjusting bar graph on the rear side of the sensor
- Tracking function with threshold tracking for fading contrast markers
- Fine adjustment of the switching threshold through "near-to-marker" teach or EasyTune (T)
- Light spot variants with horizontal or vertical alignment
- Flexible operating range of 13 mm +- 3 mm
- Maximum switching frequencies up to 22 kHz / response time 20 µs
- Small, compact housing made of nickel-plated metal, IP67 and IP69K and ECOLAB
- Reliable detection even with reflective objects.
- Operating ranges up to 24 m.
- Highly accurate positioning through extremely small laser light spot.
- Series: 5.
- Operating range, max.: 0.02 ... 4.5 m.
- Design: Cubic.
- Light source: LED, Red.
Description:
The TZIDC represents the digital, intelligent positioner for communication via HART within the positioner family. Unmatched shock and vibration immunity of 10g up to 80 Hz distinguishes the TZIDC from other‘s and guarantee reliable operation in almost all areas under harshest environmental conditions.Special Features:
■ Reliable and cost-effective ■ Design per EN 837-1 or ASME B40.100 ■ Nominal size 40 [1 ½"], 50 [2"], 63 [2 ½"], 80 [3"], 100 [4"] and 160 [6"] ■ Scale ranges to 0 ... 400 bar [0 ... 6,000 psi]Model: 111.12, back mount
Model: 111.10, lower mount (radial)
Technical Summary:
| Max. flow rate | 3300 L/h |
| Min. flow rate | 0.12 L/h |
| Max. flow rate | 872 USGPH |
| Min. flow rate | 0.03 USGPH |
| Drive speed control ratio | 3600:1 |
| Operating temperature range | 5 to 40 °C |
| Operating temperature range | 40 to 104 °F |
| Control types | EtherNet/IP™, Profibus®, Profinet®, Remote Analogue/Digital, RS485, SCADA |
| Drive standards | CE, cETLus, C-Tick, IRAM, NSF/ANSI 61 (for Marprene tubing and loadsure elements) |
| Drive ingress rating | IP66, NEMA 4X |
| Drive power supply | 100-120 V/200-240 V 1ph 50/60 Hz 350 VA |
| Compatible tubing bore size | 9.6, 12.7, 15.9, 19, 25.4 mm |
Technical Summary
| Max. flow rate | 18 L/min |
| Min. flow rate | 0.001 L/min |
| Max. flow rate | 301 USGPH |
| Min. flow rate | 0.02 USGPH |
| Drive speed control ratio | 2650:1 |
| Operating temperature range | 5 to 40 °C |
| Operating temperature range | 41 to 104 °F |
| Control types | EtherNet/IP™, Profibus®, Profinet®, Remote Analogue/Digital, RS232, RS485, SCADA |
| Drive standards | CE, cETLus, C-Tick, IRAM, NSF/ANSI 61 (for Marprene tubing and loadsure elements) |
| Drive ingress rating | IP31, IP66, NEMA 2, NEMA 4X |
| Drive power supply | 100-120 V/200-240 V 1ph 50/60 Hz 250 VA |
| Compatible tubing bore size |
Technical Summary:
| Max. flow rate | 3500 ml/min |
| Min. flow rate | 0.004 ml/min |
| Max. flow rate | 56 USGPH |
| Min. flow rate | 0 USGPH |
| Drive speed control ratio | 2200:1 |
| Operating temperature range | 5 to 40 °C |
| Operating temperature range | 40 to 104 °F |
| Control types | EtherNet/IP™, Profibus®, Profinet®, Remote Analogue/Digital, RS232, RS485, SCADA |
| Drive standards | CE, cETLus, C-Tick, IRAM, NSF/ANSI 61 (for Marprene tubing and loadsure elements), RoHS |
| Drive ingress rating | IP31, IP66, NEMA 2, NEMA 4X |
| Drive power supply | 115/230 V 1ph 50/60 Hz 135 VA |
| Compatible tubing bore size | 0.5, 1.6, 3.2, 4.8, 6.4, 8, 9.6 mm |
WATSON MARLOW 300 SERIES CASED PUMP TECHMICAL SUMMERY:
| Max. flow rate | 3000 ml/min |
| Min. flow rate | 0.002 ml/min |
| Speed control ratio | 133:1, 147:1, 200:1, 27:1, 300:1 |
| Operating temperature range | 5 to 40 °C |
| Operating temperature range | 40 to 104 °F |
| Drive standards | CE, cETLus |
| Drive ingress rating | IP31 |
| Drive power supply | 1ph, 100-120 V, 220-240 V 50/60 Hz, 100 VA |
| Compatible tubing bore size | 0.13, 0.19, 0.25, 0.38, 0.5, 0.63, 0.76, 0.8, 0.88, 1.02, 1.14, 1.29, 1.42, 1.52, 1.6, 1.65, 1.85, 2.05, 2.29, 2.54, 2.79, 3.2, 4.8, 6.4, 8 mm |
TECHNICAL SUMMERY OF WATSON MARLOW 100 SERIES CASED PUMP:
| Max. flow rate | 190 ml/min |
| Min. flow rate | 0.0001 ml/min |
| Max. flow rate | 3.04 USGPH |
| Min. flow rate | 0.00002 USGPH |
| Max. operating pressure | 2 bar |
| Max. operating pressure | 30 psi |
| Speed control ratio | 100:1, 1000:1, 200:1, 2000:1, 32:1, 320:1 |
| Operating temperature range | 5 to 40 °C |
| Operating temperature range | 40 to 104 °F |
| Standards | CE, cETLus |
| Ingress rating | IP31, NEMA 2 |
| Power supply | Supplied with 24 VDC mains transformer plug (range 90-264 VAC 47-63 Hz) which comes with multi-country adaptors |
TECHMICAL SUMMERY FOR WATSON MARLOW Quantum single-use bioprocessing pumps:
| Min. flow rate | 5.33 ml/min |
| Max. flow rate | 20 L/min |
| Max. operating pressure | 3 bar |
| Speed control ratio | 4000:1 |
| Operating temperature range | 5 to 30 °C |
| Operating temperature range | 41 to 86 °F |
| Control types | Remote Analogue/Digital |
| Standards | CE, cETLus, IEC 61010-1 |
| Ingress rating | IP66, NEMA 12/13 |
| Power supply | 100-120 V/200-240 V 1ph 50/60 Hz 250 VA |
- Transmitter: laser spot.
- Receiver.
- White OLED display.
- Control panel with control buttons.
- Status LEDs.
Qdos Chemical Metering Pumps:
Delivering flow rates that remain constant right up to 7 bar Qdos chemical metering pumps give users a unique advantage over diaphragm metering pumps. Qdos pumps offer long maintenance intervals - reducing the impact of process downtime and lowering the overall cost of ownership.Independent data logger and IOT Gateway
♦Power supply options come in a variety of forms. ♦Using the most effective source for communication. ♦with up to 7 sensors and 12 measurement types.A robust, Ø78 mm, programmable hollow shaft angle transmitter
detects the angular position of a shaft without making contact with it and
transforms the information into an impressed direct current proportional to the measured value.
Features:-
-
Hollow-shaft angle-of-rotation transmitter with a tough, weatherproof design.
-
Highest level of electrical and mechanical safety.
-
Advanced capacitive scanning system.
-
Easy axis or shaft mounting.
-
Installing a continuous shaft.
-
Enduring, upkeep-free, and simple to install.
-
Shake- and vibration-resistant.
-
Keys and switches can be used to parameterize the measuring range, rotational direction, zero point, and characteristic curve (linear/V).
-
Analog output signal, 2-wire connector, 4...20 mA.
-
Independently adjustable zero point and span.
-
Due to the capacitive scanning mechanism, the absolute position is immediately available after turning on.
An angle proportional inclination is transformed into a DC signal using the KINAX N702.
An analog current change (4–20 mA) that represents the output signal is accessible.
There is little mechanical wear on the pendulum from the sensor, which is non-contact.
Features:-
- Magnetoresistive inclination transducer
- Digital interfaces CANopen
- Robust aluminum housing
- Protection class IP66
- Oil damped pendulum
- Pendulum shaft without mechanical stop
- Series 21PY.
- Series 21C.
- Series 23SY.
- Series 25Y.
KOBOLD room thermostats are suitable for industrial plants, greenhouses, and warehouses, and also for monitoring the maximum temperature in switchgear cabinets and relay stations. Room thermostats are supplied with TER-H 1 wall brackets.
Switching range:- -20 ... +20 ... +80 ... +130°C, adjustable. Material:-aluminum (housing). copper, brass, or stainless steel (probe). Micro switch:- SPDT max. 250 VAC, 8 (5) A at 250 VAC, 8 A at 24 VDC.ELECTROMAGNETIC FLOWMETER
- High accuracy (±0.2%), with CT approvals (OIML R49, MI-001)
- 0D/0D installation acc. to MID MI-001 and OIML R49 accuracy class 1
- Flange: DN25…3000 / 1…120", max. PN40 / ASME Cl 300
- 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET
VU 570 - Vortex ultrasonic sensor for flow measurement
Independent of the gas composition, flow meters for technical gases and mixed gases.FA 500 - Dew point sensor with integrated display and alarm relay
- Dew point sensor FA 500 from -80 to 20°Ctd.
- For refrigeration, membrane, and desiccant dryers, the FA 500 is the perfect dew point sensor with an integrated display and warning relay.
Ultrasonic flowmeter
✓ Suitable for use with both conductive and non-conductive liquids. ✓ Due to the seal-free sensor, there is high process safety. ✓ The measurement tube can move easily.MODEL:-F630
Magnetic inductive flowmeter, small or separate ✓ The suitable device for every application, with a wide range of options. ✓ Possible spared variation. ✓ ATEX-Authorization. ✓ Applications for hygiene. ✓ Mechanism for detecting errors.Multivariable, simple, and user-friendly smart magmeter for utilities
♦ Decent design.
♦ Enclosed control panel.
♦ Parameterization is possible via Bluetooth.
- Dependable optical measuring of distance with great ranges up to 6 m.
- There are two switching outputs, one of which can be programmed to be an analog output.
- window and a scalable measuring range.
- For the requirements of the automotive sector, laser protection class 1.
- Great value for the money.
TCN4S-24R
- Display method : 4-digit 7-segment LED
- Control method : ON/OFF, P, PI, PD, PID
- Input specification : Thermocouple: K(CA), J(IC), T(CC), R(PR), S(PR), L(IC) RTD: DPt100Ω, Cu50Ω
- Sampling cycle : 100ms
- Control output : Relay(250VAC~ 3A) or SSR drive(12VDC ) [ON/OFF]
- Power supply : 100-240VAC~ 50/60Hz
Danfoss FC 51 Micro Drive 0.37KW 3ph 400V Inverter
Danfoss 0.37KW VLT Micro Drive
Specifications
Attribute |
Value |
For Use With |
SIMATIC S7-200 Series |
Manufacturer Series |
S7-200 |
Number of Inputs |
14 |
Number of Digital Inputs |
14 |
Output Type |
Analogue, Digital, Transistor |
Voltage Category |
20.4 → 28.8 V dc |
Input Type |
Analogue, Digital |
Number of Digital Outputs |
10 |
Number of Outputs |
10 |
Communication Port Type |
RS485 |
Program Capacity |
12 kB |
Programming Language Used |
AWL, FUP, Ladder Logic |
Mounting Type |
Rack Mount |
Programming Interface |
Computer, SIMATIC PG/PC |
Output Current |
750 mA |
Number of Communication Ports |
1 |
Battery Backup |
Yes |
Length |
80mm |
Memory |
12 (Program Memory) kB, 8 (Data Memory) kB |
Width |
120.5mm |
Dimensions |
80 x 120.5 x 62 mm |
Maximum Operating Temperature |
+45°C |
Minimum Operating Temperature |
0°C |
Depth |
62mm |
FA-COM PLC: Analogue I/O Module
| Series | MELSEC-F SERIES |
|---|---|
| Type | FX3U |
| Power Supply (V) | 24 |
| Current Type | DC |
| Occupied I/O Points on PLC | 8 |
| Integrated Analogue Outputs | 4 |
| Output Voltage Range (V) | 0-10 |
| Output Current Range (mA) | 4-20 |
| Min. Ambient Temperature (°C) | 0 |
| Max. Ambient Temperature (°C) | 55 |
- Manufacturer : DELTA
- Product No. : DVP32ES200R
- Product Type : Programmable Logic Controller DVP Series
- DVP-ES2 Series Standard PLC
- Power Supply : 100 ~ 240 V
- Output Method : Relay
- Inputs : 16
- Outputs : 16
- Display method : 4-digit 7-segment LED.
- Control method : ON/OFF, P, PI, PD, PID.
- Input specification : Thermocouple: K(CA), J(IC), E(CR), T(CC), B(PR), R(PR), S(PR), N(NN), C(TT), G(TT), L(IC), U(CC), Platinel II. RTD: DPt100Ω, DPt50Ω, JPt100Ω, Cu100Ω, Cu50Ω, Nikel 120Ω. Analog: 0-100mV, 0-5V, 1-5V, 0-10V. 0-20mA, 4-20mA.
- Sampling cycle : 50ms.
- Control output 1 : Current(DC0/4-20mA) or SSR drive(11VDC
) [ON/OFF].
- Option output : Alarm 1, RS485 comm.
- Power supply : 100-240VAC~ 50/60Hz.
- Protection structure : IP65(front panel).
- Display method: 4-digit 7-segment LED.
- Control method: ON/OFF control, P, PI, PD, PIDF, PIDS control.
- Input specification : Thermocouple: K(CA), J(IC), E(CR), T(CC), R(PR), S(PR), N(NN), W(TT) RTD: DPt100Ω, JPt100Ω
- Analog: 1-5VDC , 0-10VDC , DC4-20mA..
- Sampling cycle: 500ms.
- Control output : Relay(250VAC~ 3A).
- Power supply : 100-240VAC~ 50/60Hz.
- SIMATIC HMI TP900 Comfort.
- Comfort Panel.
- Touch operation.
- 9 "TFT display (widescreen).
- 16 million Colours.
- PROFINET interface.
- MPI/PROFIBUS-DP interface.
- Configuration memory: 12 MByte.
- Windows CE 6.0 (Microsoft-Support incl. Security updates discontinued) configurable from WinCC Comfort V11.
- MASTER-K80S/120S
- Compact and high-function block type.
- Program capacity: 7k steps/10k steps.
- Various main and expansion modules.
- High-function built-in functions: Input filter, Positioning, PID, HSC, built-in Cnet.
- Diverse special/network modules On-line edit support.
-
Primary brand:-Mitsubishi Electric.
-
Main function:-CPU unit.
-
Product series / family name :-MELSEC-F (FX) Series.
-
Sub-range name :-FX3U.
-
Mounting mode :-DIN rail.
| Task: | Program |
|---|---|
| Function: | Automatic Control |
| Certification: | RoHS, CE |
| Condition: | New |
| Customized: | Non-Customized |
| Transport Package: | 1PC/Carton |
DC digital output module - Mitsubishi Electric (MELSEC-F (FX) Series FX2N) - 16I/O [16DO (16 x digital outputs (Rly. NO contacts; 2A / 240Vac or 24Vdc))] - with screw-clamp term. connections - DIN rail mounting - equivalent to FX2N16EYRESUL.
SITOP power supplies
The 24 V/20 A SITOP power supplies are built-in units, IP20 degree of protection, protection class I. Primary switched-mode power supplies for connection to 1-phase AC system (TN or TT system in accordance with VDE 0100 T 300 / IEC 364-3) with rated voltages of 120/230 V, 50/60 Hz; +24 V DC output voltage, isolated, shortcircuit- proof and idling-proof.- Reliable sensor for standard applications.
- Miniature design with versatile mounting options.
- Reliable recognition of reflective objects and clear glass.
- Two machines in one: clear object detection or reflection operating mode with long range.
- TEACH-IN switch for setting the contrast detection levels.
- Automatic adjustment in case of soiling in contrast detection mode.
- Certified by ECOLAB.
| Series | MELSEC-F SERIES |
|---|---|
| Type | FX3U |
| Power Supply (V) | 24 |
| Current Type | DC |
| Integrated Analogue Inputs | 4 |
| Input Type | THERMOCOUPLE |
| Applicable Thermocouple Type | K,J |
- Power: 5.5kW.
- Amps: 13.
- Supply: Three Phase 400v.
- Model: Delta VFD055E43A.
- Filter: Built-In.
- Performance: Mid Range.
- Dimensions: 130 x 260 x 169.2.
- Weight: 4.2kg.
- Torque: Constant Torque General Purpose.
High-end Programmable Logic Controller (PLC) CPU unit with built-in I/Os - Mitsubishi Electric (MELSEC-F (FX) Series FX3U) - 32I/O [16DI (16 x digital inputs (24Vdc; Sink/Source)) + 16DO (16 x digital outputs (Rly NO contacts; 2A / 240Vac or 30Vdc; 10ms response))] - 64Ksteps (RAM; Program) memory capacity - connection capacity 256 x I/O points - with screw-clamp term. connections (I.O's) - with RS-422 communication capability - Supply voltage 100Vac-240Vac (120Vac / 208Vac / 220Vac / 230Vac) - DIN rail mounting (150mm width) - equivalent to FX3U32MRES.
SIMATIC DP, Electronics module f. ET200S, 2AI TC High Feature, 15 mm width, 15 bit+sign with internal temperature Compensation.
Specifications:-
- Output frequency: 0.1~600Hz.
- 3 points adjustable V/f curve.
- Built-in PID feedback control.
- RFI-switch for IT mains.
- Built-in EMI filter (for models 230V 1-phase and 460V 3-phase).
- Use RS-485 communication interface (RJ-45) with Modbus protocol.
- Optional communication modules for multiple communication protocols, such as Profibus, DeviceNet, LonWorks and CANopen.
- Complete protection function.
- Housing: Standard design.
- Sensing range Sn: 6 mm.
- Installation type: Quasi-flush.
- Electrical wiring: DC 3-wire.
- Switching output: PNP.
- Output function: NO.
- Connection type: Male connector M12, 4-pin.
Core features
- Available in NEMA 1, 3R, 4, 4X, 12 enclosures for a broad range of application environments.
- Most common disconnect switches in stock and ship within 24 hours with QuikShip Everyday Service to meet project requirements.
- Multiple field-installed accessories enhance the enclosed disconnect switches to fit the desired application.
- UL 508 Listed for motor disconnect applications.
- 3- and 6-Pole UL 508 motor disconnect switches provide flexibility for single or dual motor applications.
- NEMA 4X 30A and 60A motor control disconnects.
System pro M compact®
With System pro M compact® ABB offers an extra-wide and complete range of miniature circuit breakers to cover most applications and markets. Our products are compliant to worldwide product standards (IEC, UL, CSA). With over 90 years of experience of innovation in the electrical sector, we offer established and certified quality.- Compliant to worldwide product standards (IEC, UL, CSA)
- Characteristics: B, C, D, K, Z
- Configurations: 1P, 1P+N, 2P, 3P, 3P+N, 4P
- Breaking capacities up to 25 kA
- Rated currents up to 100 A
- LOGO DM8 24R expansion module.
- Voltage supply inputs: 24 V AC/DC.
- Outputs: relay.
- 4 DI (Digital Inputs).
- 4 DO (Digital Outputs).
- NPN input.
- For LOGO 8.
- Diffusing signals without loss.
- The transformation of SinCos to digital.
- 4 simultaneous output signals, maximum.
- In order to ensure quality, completeness, position, and existence.
- Verification of contours without regard to orientation.
- Independent gadget with built-in lighting.
- User-friendly, intuitive handling.
- An Ethernet interface with high throughput for data transmission.
- Dual color indication LED.
- High switching frequency.
- Light-on/dark-on, programmable.
- Strong metallic housing in cylindrical shape M18 x 1.
- Degree of protection IP67.
Voltec Engineering Limited
Automation and control products are the focus of VOLTEC ENGINEERING LIMITED. In the area of comprehensive industry solutions for alteration, upgrading, and new construction projects, VOLTEC ENGINEERING LIMITED is a one-stop solution provider.
Need Help?
01326 708335
01329 727092
Customer Service
© 2025 Voltec Engineering Ltd. | Design & Developed by mPair Technologies Ltd.