SICK Contrast Sensor KT5W-2N1116, 1018045

 

  • Switching Output: NPN
  • Supply Voltage: 10 V DC … 30 V DC
  • Ripple: ≤ 5 Vpp
  • Current Consumption: < 80 mA
  • Switching Frequency: 10 kHz
  • Response Time: 50 µs

Description

SICK Contrast Sensor KT5W-2N1116, 1018045

KT5W-2N1116, 1018045

Contrast Sensor

The SICK Contrast Sensor is a precision optical sensor designed for detecting contrast differences in industrial automation. Equipped with an RGB LED light source, it accurately identifies color variations across various surfaces. With a switching frequency of 10 kHz and a response time of 50 µs, it ensures high-speed and reliable detection in fast-moving production environments. The IP67-rated enclosure and robust zinc diecast housing provide durability in harsh industrial conditions. Ideal for print mark detection, labeling, and packaging applications, this NPN contrast sensor features M12 5-pin connectivity and includes short-circuit and reverse polarity protection for enhanced operational safety.

Specifications:-

Features
Dimensions (W x H x D) 30.4 mm x 53 mm x 80 mm
Sensing distance ≤ 10 mm ¹⁾
Housing design Rectangular
Light source LED, RGB ²⁾
Wavelength 470 nm, 525 nm, 640 nm
Light emission Long and short side of housing, exchangeable
Light spot size 1.2 mm x 4.2 mm
Light spot direction Vertical ³⁾
Adjustment Teach-in button
Teach-in mode Static 2-point teach-in
1) From leading edge of lens.

2) Average service life: 100,000 h at TU = +25 °C.

3) In relation to long side of housing.

 

Mechanics/Electronics
Supply Voltage 10 V DC … 30 V DC¹
Ripple ≤ 5 Vpp²
Current Consumption < 80 mA³
Switching Frequency 10 kHz⁴
Response Time 50 µs
Switching Output NPN
Switching Output (Voltage) NPN: HIGH = approx. UV / LOW ≤ 2 V
Output Current Imax. 100 mA⁶
Input, Teach-In (ET) NPN Teach: U < 2 V, Run: U = 10 V … < UV
Retention Time (ET) 25 ms, non-volatile memory
Connection Type Male connector M12, 5-pin
Protection Class II⁷
Circuit Protection UV connections, reverse polarity protected
Output Q Protection Short-circuit protected
Interference Pulse Suppression Yes
Enclosure Rating IP67
Weight 400 g
Housing Material Metal, zinc diecast
1) Limit values when operated in short-circuit protected network: max. 8 A. 
2) May not exceed or fall below Uv tolerances. 
3) Without load. 
4) With light/dark ratio 1:1. 
5) Signal transit time with resistive load. 
6) Short-circuit-proof. 
7) Reference voltage DC 50 V.
Ambient Data
Ambient operating temperature –10 °C … +55 °C
Ambient temperature, storage –25 °C … +75 °C
Shock load According to IEC 60068

Datasheet: PDF

 

Possible Leuze Electronic Replacement: KRT21M-09.PL3/42-M12, 50127841 (In Stock)