Leuze Polarized Retro-Reflective Photoelectric Sensor PRK25C.TT3/4P-M8, 50139676

  • RANGE:- 0-3m.
  • OUTPUT:- PNP-LIGHT SWITCHING, PNP-DARK SWITCHING.
  • SUPPLY VOLTAGE:-10-30VDC, 4-PIN.
  • M8 CONNECTOR.
  • METAL HOUSING.

Description

Leuze Polarized Retro-Reflective Photoelectric Sensor PRK25C.TT3/4P-M8, 50139676

Polarized Retro-Reflective Photoelectric Sensor

Specifications:-

Basic Data:-

Series 25C
Operating principle Reflection principle
Application Detection of highly transparent bottles
Detection of transparent films

Special Version:-

Special version Autocollimation
Tracking function

Optical Data:-

Operating range 0 … 3 m, With reflector TK(S) 100×100
Operating range Guaranteed operating range
Operating range limit 0 … 3.6 m, With reflector TK(S) 100×100
Operating range limit Typical operating range
Light source LED, Red
Wavelength 640 nm
LED group Exempt group (in acc. with EN 62471)

Electrical Data:-

Protective circuit Polarity reversal protection
Short circuit protected

Performance Data:-

Supply voltage UB 10 … 30 V, DC, Incl. residual ripple
Residual ripple 0 … 15 %, From UB
Open-circuit current 0 … 20 mA

Outputs:-

Number of digital switching outputs 2 Piece(s)

Switching Outputs 1:-

Switching element Transistor, PNP
Switching principle Light switching

Switching Outputs 2:-

Switching element Transistor, PNP
Switching principle Dark switching

Time Behavior:-

Switching frequency 1,500 Hz
Response time 0.33 ms
Readiness delay 300 ms

Connection:-
Connection 1:-

Function Signal OUT
Voltage supply
Type of connection Connector
Thread size M8
Type Male
Material PUR
No. of pins 4 -pin

Mechanical Data:-

Dimension (W x H x L) 15 mm x 42.7 mm x 30 mm
Housing material Plastic
Plastic housing ABS
Lens cover material Plastic
Net weight 22 g
Housing color Red
Type of fastening Through-hole mounting with M4 thread
Via optional mounting device
Compatibility of materials ECOLAB

Operation & Display:-

Type of display LED
Operational controls Teach button
Function of the operational control Sensitivity adjustment

Environmental Data:-

Ambient temperature, operation -40 … 60 °C
Ambient temperature, storage -40 … 70 °C

Data Sheet: Pdf