SICK Contrast Sensor KT5W-2P1116, 1018044

  • Switching Output: PNP
  • Supply Voltage: 10 V DC … 30 V DC
  • Ripple: ≤ 5 Vpp
  • Current Consumption: < 80 mA
  • Switching Frequency: 10 kHz
  • Response Time: 50 µs

Description

SICK Contrast Sensor KT5W-2P1116, 1018044

KT5W-2P1116, 1018044

Contrast Sensor

The SICK Contrast Sensor is a high-performance optical sensor designed for precise detection of contrast differences in industrial automation applications. Featuring an RGB LED light source, it ensures accurate color detection across various surfaces. With a fast switching frequency of 10 kHz and a response time of just 50 µs, this sensor delivers rapid and reliable performance in high-speed production lines. Its IP67-rated enclosure and robust zinc diecast housing make it durable for harsh industrial environments. Ideal for print mark detection, labeling, and packaging applications, this PNP contrast sensor supports M12 5-pin connectivity and offers short-circuit and reverse polarity protection.

Specifications:-

Features
Dimensions (W x H x D) 30.4 mm x 53 mm x 80 mm
Sensing distance ≤ 10 mm ¹⁾
Housing design Rectangular
Light source LED, RGB ²⁾
Wavelength 470 nm, 525 nm, 640 nm
Light emission Long and short side of housing, exchangeable
Light spot size 1.2 mm x 4.2 mm
Light spot direction Vertical ³⁾
Adjustment Teach-in button
Teach-in mode Static 2-point teach-in
1) From leading edge of lens.

2) Average service life: 100,000 h at TU = +25 °C.

3) In relation to long side of housing.
Mechanics/Electronics
Supply voltage 10 V DC … 30 V DC¹⁾
Ripple ≤ 5 Vpp²⁾
Current consumption < 80 mA³⁾
Switching frequency 10 kHz⁴⁾
Response time 50 µs⁵⁾
Switching output PNP
Switching output (voltage) PNP: HIGH = UV ≤ 2 V / LOW approx. 0 V
Output current Imax. 100 mA⁶⁾
Input, teach-in (ET) PNP Teach: U = 10 V … < UV Run: U < 2 V
Retention time (ET) 25 ms, non-volatile memory
Connection type Male connector M12, 5-pin
Protection class II⁷⁾
Circuit protection UV connections, reverse polarity protected
Output Q Short-circuit protected
Interference pulse suppression Yes
Enclosure rating IP67
Weight 400 g
Housing material Metal, zinc diecast
1) Limit values when operated in short-circuit protected network: max. 8 A.

2) May not exceed or fall below Uv tolerances.

3) Without load.

4) With light/dark ratio 1:1.

5) Signal transit time with resistive load.

6) Short-circuit-proof.

7) Reference voltage DC 50 V.
Ambient Data
Ambient operating temperature –10 °C … +55 °C
Ambient temperature, storage –25 °C … +75 °C
Shock load According to IEC 60068

Datasheet: PDF

 

Possible Leuze Electronic Replacement: KRT21M-09.PL3/42-M12, 50127841 (In Stock)