Omron Timer H3Y-2 AC200-230 60S , 200 to 230 VAC 50/60 Hz
- 200 to 230 VAC 50/60 Hz.
- Output Time-limit: DPDT.
- Power ON-delay.
- Time range: 2 to 60 s (1 range).
- 8-pin.
Description
Omron Timer H3Y-2 AC200-230 60S , 200 to 230 VAC 50/60 Hz
TECHNICAL DATA:-
Rated power supply voltage | 200 to 230 VAC 50/60 Hz |
---|---|
Allowable voltage variable range | 85 to 110% of the power supply voltage |
Power consumption | Approx. 1.8 VA (at 230 VAC) |
Reset voltage | 10% min, of rated supply voltage |
Number of time ranges | 1 |
Operation mode | Power ON-delay |
Control output (Type) | Time-limit: DPDT |
Control output (Contact output) | Resistive load: 250 VAC 5 A (cosφ=1) Minimum applicable load: 1 mA at 5 VDC (failure level: P) |
Operating resetting | Time-limit operation/Self-reset |
Ambient temperature range | Operating: -10 to 50 ℃ (with no icing) Storage: -25 to 65 ℃ (with no icing) |
Ambient humidity range | Operating: 35 to 85% |
Accuracy of operating time | ±1% FS max. |
Setting error | ±10% FS ±50 ms max. |
Reset time | 0.1 s max. (including halfway reset) |
Influence of voltage | ±2% FS max. |
Influence of temperature | ±2% FS max. |
Insulation resistance | 100 MΩ min. (at 500 VDC) |
Dielectric strength | Between current carrying terminals and exposed non-current carrying metal parts: 2000 VAC 50/60 Hz 1 min (Terminal screw sections are not excluded) Between operating power circuit and control output: 2,000 VAC 50/60 Hz 1 min Between contacts of different polarity: 2,000 VAC 50/60 Hz 1 min Between non-continuous contacts: 1,000 VAC 50/60 Hz 1 min |
Impulse withstand voltage | Between power terminals: 3 kV Between current carrying terminals and exposed non-current carrying metal parts: 4.5 kV |
Noise immunity | ±1.5 kV square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) |
Static immunity | Mulfunction: 4 kV, Destruction: 8 kV |
Vibration resistance | Destruction: 10 to 55 Hz, 0.75 mm single amplitude each in 3 directions for 1 hour Malfunction: 10 to 55 Hz, 0.5 mm single amplitude each in 3 directions for 10 min |
Shock resistance | Destruction: 1,000 m/s2, 3 times each in 6 directions Malfunction: 100 m/s2, 3 times each in 6 directions |
Life expectancy (relay output) | Electrical: 500,000 operations min. (5 A at 250 VAC, resistive load at 1,800 operations/h, Room temperature) Mechanical: 10 million operations min. (under no load at 1,800 operations/h) |
Degree of protection | IP40 |
Connecting method | 8-pin round socket |
Case color | Beige |
Weight | Approx. 50 g |
MODEL:-
H3Y-2 AC100-120 0.5S ,H3Y-2 AC100-120 10M, H3Y-2 AC100-120 10S, H3Y-2 AC100-120 120S ,H3Y-2 AC100-120 1S ,H3Y-2 AC100-120 30M ,H3Y-2 AC100-120 30S ,H3Y-2 AC100-120 3H ,H3Y-2 AC100-120 3M ,H3Y-2 AC100-120 5M ,H3Y-2 AC100-120 5S, H3Y-2 AC100-120 60M, H3Y-2 AC100-120 60S, H3Y-2 AC200-230 0.5S, H3Y-2 AC200-230 10M ,H3Y-2 AC200-230 10S ,H3Y-2 AC200-230 120S ,H3Y-2 AC200-230 1S ,H3Y-2 AC200-230 30M ,H3Y-2 AC200-230 30S ,H3Y-2 AC200-230 3H, H3Y-2 AC200-230, 3M H3Y-2 AC200-230, 5M H3Y-2 AC200-230 5S ,H3Y-2 AC200-230 60M ,H3Y-2 AC200-230 60S, H3Y-2 DC100-110 0.5S ,H3Y-2 DC100-110 10M ,H3Y-2 DC100-110 10S ,H3Y-2 DC100-110 120S ,H3Y-2 DC100-110 1S, H3Y-2 DC100-110 30M ,H3Y-2 DC100-110 30S ,H3Y-2 DC100-110 3H ,H3Y-2 DC100-110 3M ,H3Y-2 DC100-110 5M ,H3Y-2 DC100-110 5S ,H3Y-2 DC100-110 60M, H3Y-2 DC100-110 60S, H3Y-2 DC12 0.5S.
DATA SHEET-PDF