SCHNEIDER Magnetic Contactor TeSys LC1D32M7

Add to Wishlist
Add to Wishlist

MODEL-LC1D32M7

TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 32 A – 220 V AC coil.

Description

SCHNEIDER Magnetic Contactor TeSys LC1D32M7

Main

Range of product                                   TeSys Deca Product or component type               Contactor Device short name                                LC1D

Contactor application                           Resistive load Motor control

 

Utilisation category                               AC-4 AC-1 AC-3 AC-3e

 

Poles description                                   3P

 

[Ue] rated operational voltage           Power circuit: <= 690 V AC 25…400 Hz

Power circuit: <= 300 V DC

 

[Ie] rated operational current            32 A (at <60 °C) at <= 440 V AC AC-3 for power circuit

50 A (at <60 °C) at <= 440 V AC AC-1 for power circuit

32 A (at <60 °C) at <= 440 V AC AC-3e for power circuit

 

[Uc] control circuit voltage                220 V AC 50/60 Hz

 

 

Complementary

Motor power kW                                    7.5 kW at 220…230 V AC 50/60 Hz (AC-3) 15 kW at 380…400 V AC 50/60 Hz (AC-3)

15 kW at 415…440 V AC 50/60 Hz (AC-3)

18.5 kW at 500 V AC 50/60 Hz (AC-3)

18.5 kW at 660…690 V AC 50/60 Hz (AC-3)

7.5 kW at 400 V AC 50/60 Hz (AC-4)

7.5 kW at 220…230 V AC 50/60 Hz (AC-3e)

15 kW at 380…400 V AC 50/60 Hz (AC-3e)

15 kW at 415…440 V AC 50/60 Hz (AC-3e)

18.5 kW at 500 V AC 50/60 Hz (AC-3e)

18.5 kW at 660…690 V AC 50/60 Hz (AC-3e)

 

Motor power hp                                      2 hp at 115 V AC 50/60 Hz for 1 phase motors

5 hp at 230/240 V AC 50/60 Hz for 1 phase motors

7.5 hp at 200/208 V AC 50/60 Hz for 3 phases motors

10 hp at 230/240 V AC 50/60 Hz for 3 phases motors

20 hp at 460/480 V AC 50/60 Hz for 3 phases motors

30 hp at 575/600 V AC 50/60 Hz for 3 phases motors

 

Compatibility code                                LC1D

 

Pole contact composition                   3 NO

 

Contact compatibility                            M2

 

Protective cover                                    With

 

SCHNEIDER Magnetic Contactor TeSys LC1D32M7

[Ith] conventional free air thermal current

10 A (at 60 °C) for signalling circuit 50 A (at 60 °C) for power circuit

Rated breaking capacity                     550 A at 440 V for power circuit conforming to IEC 60947

 

 

[Icw] rated short-time withstand current

260 A 40 °C – 10 s for power circuit 430 A 40 °C – 1 s for power circuit 60 A 40 °C – 10 min for power circuit 138 A 40 °C – 1 min for power circuit 100 A – 1 s for signalling circuit

120 A – 500 ms for signalling circuit 140 A – 100 ms for signalling circuit

 

Associated fuse rating                         10 A gG for signalling circuit conforming to IEC 60947-5-1

63 A gG at <= 690 V coordination type 1 for power circuit 63 A gG at <= 690 V coordination type 2 for power circuit

 

Average impedance                              2 mOhm – Ith 50 A 50 Hz for power circuit

 

Power dissipation per pole                 2 W AC-3

5 W AC-1

2 W AC-3e

 

[Ui] rated insulation voltage               Power circuit: 690 V conforming to IEC 60947-4-1

Power circuit: 600 V CSA certified Power circuit: 600 V UL certified

Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified

Signalling circuit: 600 V UL certified

Overvoltage category                         III

Pollution degree                                     3

 

[Uimp] rated impulse withstand voltage

6 kV conforming to IEC 60947

 

 

Safety reliability level                           B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1

B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1

 

Mechanical durability                            15 Mcycles

 

Electrical durability                               1.65 Mcycles 32 A AC-3 at Ue <= 440 V

1.4 Mcycles 50 A AC-1 at Ue <= 440 V

1.65 Mcycles 32 A AC-3e at Ue <= 440 V

 

Control circuit type                               AC at 50/60 Hz standard

 

Coil technology                                       Without built-in suppressor module

 

Control circuit voltage limits              0.3. 0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz

0.8. 1.1 Uc (-40…60 °C):operational AC 50 Hz

0.85. 1.1 Uc (-40…60 °C):operational AC 60 Hz

  1. 1.1 Uc (60…70 °C):operational AC 50/60 Hz

 

Inrush power in VA                               70 VA 60 Hz cos phi 0.75 (at 20 °C) 70 VA 50 Hz cos phi 0.75 (at 20 °C)

 

 

Hold-in power consumption in VA

7.5 VA 60 Hz cos phi 0.3 (at 20 °C) 7 VA 50 Hz cos phi 0.3 (at 20 °C)