OMRON RELAYS MKS3P DC24

Add to Wishlist
Add to Wishlist
  • Compact Power Relays
  • 3 poles
  • Plug-in terminal
  • 24 VDC
Category:
Tags:

Description

OMRON RELAYS MKS3P DC24

OMRON RELAYS

Performance
Operating indicator Mechanical indicator
Degree of protection Closed type (cover)
Terminal structure Plug-in terminal
Coil Coil ratings 24 VDC 55.8 mA
Coil resistance 430 Ω
Operate voltage (Set voltage) 80 % max.
Release voltage (Reset voltage) 15 % min.
Maximum voltage 110 %
Power consumption Approx. 1.4 W
Contact Contact rated load 250 VAC 10 A (NO contact: Resistive load)
250 VAC 5 A (NC contact: Resistive load)
250 VAC 7 A (Inductive load (cosφ = 0.4))
30 VDC 10 A (NO contact: Resistive load)
30 VDC 5 A (NC contact: Resistive load)
Max. contact voltage 250 VAC
250 VDC
Max. contact current AC: 10 A
DC: 10 A
Maximum switching power 2500 VA (NO contact: Resistive load)
1250 VA (NC contact: Resistive load)
1750 VAAC (Inductive load (cosφ = 0.4))
300 W (NO contact: Resistive load)
150 W (NC contact: Resistive load)
Contact form 3PDT
Contact method Single
Contact material AgSnIn
 
Contact resistance 100 mΩ max. (Voltage drop method with 5 VDC 1 A)
Operating time 30 ms max. (With rated operating power applied, 23 ℃, not including contact bounce)
Reset time 20 ms max. (With rated operating power applied, 23 ℃, not including contact bounce)
Maximum operating frequency Mechanical: 18000 time/hour
Rated load: 1800 time/hour
Insulation resistance Between coil and contacts: 100 MΩ min. (at 500 VDC)
Between contacts of different polarity: 100 MΩ min. (at 500 VDC)
Between contacts of same polarity: 100 MΩ min. (at 500 VDC)
Dielectric strength Between coil and contacts: 2500 VAC 50/60 Hz 1 min
Between contacts of different polarity: 2500 VAC 50/60 Hz 1 min
Between contacts of same polarity: 1000 VAC 50/60 Hz 1 min
Vibration resistance (destruction) 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Vibration resistance (Malfunction) 10 to 55 to 10 Hz, 0.5-mm single amplitude (1-mm double amplitude)
Shock resistance (destruction) 1000 m/s2
Shock resistance (Malfunction) 100 m/s2
Endurance (Mechanical) 5,000,000 operations min. (switching frequency 1,800 operations/h)
Endurance (Electrical) 100,000 operations min. (23 ℃, Rated load, switching frequency 1,800 operations/h)
Failure rate 1 VDC 10 mA (failure level: Preference value, Switching frequency: 30 operations per minute)
Ambient temperature (Operating) -40 to 60 ℃
Ambient humidity (Operating) 5 to 85 %
Weight Approx. 90 g
Mounting method Socket
Applicable socket PF113A-E/ PF113A

 

MODEL:

MK3P-I-380VAC

MK3P-I-220VAC

MK3P-I-110VAC

MK3P-I-24VAC

MK3P-I-24VDC