OMRON RELAYS MKS2P DC24
Add to Wishlist
Add to Wishlist
- Compact Power Relays
- 2 poles
- 24 VDC 55.8 mA
- Mechanical indicator
- DPDT
- Plug-in terminal
Description
OMRON RELAYS MKS2P DC24
OMRON RELAYS
Operating indicator | Mechanical indicator | |
---|---|---|
Degree of protection | Closed type (cover) | |
Terminal structure | Plug-in terminal | |
Coil | Coil ratings | 24 VDC 55.8 mA |
Coil resistance | 430 Ω | |
Operate voltage (Set voltage) | 80 % max. | |
Release voltage (Reset voltage) | 15 % min. | |
Maximum voltage | 110 % | |
Power consumption | Approx. 1.4 W | |
Contact | Contact rated load | 250 VAC 10 A (NO contact: Resistive load) 250 VAC 5 A (NC contact: Resistive load) 250 VAC 7 A (Inductive load (cosφ = 0.4)) 30 VDC 10 A (NO contact: Resistive load) 30 VDC 5 A (NC contact: Resistive load) |
Max. contact voltage | 250 VAC 250 VDC |
|
Max. contact current | AC: 10 A DC: 10 A |
|
Maximum switching power | 2500 VA (NO contact: Resistive load) 1250 VA (NC contact: Resistive load) 1750 VAAC (Inductive load (cosφ = 0.4)) 300 W (NO contact: Resistive load) 150 W (NC contact: Resistive load) |
|
Contact form | DPDT | |
Contact method | Single | |
Contact material | AgSnIn |
Contact resistance | 100 mΩ max. (Voltage drop method with 5 VDC 1 A) |
---|---|
Operating time | 30 ms max. (With rated operating power applied, 23 ℃, not including contact bounce) |
Reset time | 20 ms max. (With rated operating power applied, 23 ℃, not including contact bounce) |
Maximum operating frequency | Mechanical: 18000 time/hour Rated load: 1800 time/hour |
Insulation resistance | Between coil and contacts: 100 MΩ min. (at 500 VDC) Between contacts of different polarity: 100 MΩ min. (at 500 VDC) Between contacts of same polarity: 100 MΩ min. (at 500 VDC) |
Dielectric strength | Between coil and contacts: 2500 VAC 50/60 Hz 1 min Between contacts of different polarity: 2500 VAC 50/60 Hz 1 min Between contacts of same polarity: 1000 VAC 50/60 Hz 1 min |
Vibration resistance (destruction) | 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) |
Vibration resistance (Malfunction) | 10 to 55 to 10 Hz, 0.5-mm single amplitude (1-mm double amplitude) |
Shock resistance (destruction) | 1000 m/s2 |
Shock resistance (Malfunction) | 100 m/s2 |
Endurance (Mechanical) | 5,000,000 operations min. (switching frequency 1,800 operations/h) |
Endurance (Electrical) | 100,000 operations min. (23 ℃, Rated load, switching frequency 1,800 operations/h) |
Failure rate | 1 VDC 10 mA (failure level: Preference value, Switching frequency: 30 operations per minute) |
Ambient temperature (Operating) | -40 to 60 ℃ |
Ambient humidity (Operating) | 5 to 85 % |
Weight | Approx. 90 g |
Mounting method | Socket |
Applicable socket | PF083A-E/ PF083A |
MODEL:
MK3P-I-380VAC
MK3P-I-220VAC MK3P-I-110VAC MK3P-I-24VAC MK3P-I-24VDC |