Emerson-Rosemount 8800 MultiVariable Vortex Flow Meter
Description
Emerson-Rosemount 8800 Multi Variable Vortex Flow Meter
Features:
♦ The capacity to compensate for temperature and pressure allows for the measurement of steam & liquid mass flow without the use of a flow computer.
♦ Without the use of a separate temperature sensor or external thermowell, the integrated temperature sensor enables reliable temperature measurement.
♦ Superheat Diagnostics aids in the detection of liquid applications for superheated steam deterioration.
♦ Use up to five user-defined temperature and density pairs to compensate for any liquid flow.
♦ The 4-20 mA digital or pulse output can be used to assign flow and temperature variables, allowing for more sophisticated monitoring possibilities.
♦ The unique, gasket-free meter body design eliminates potential leak points, increasing plant availability and decreasing maintenance costs.
♦ A higher level of safety assurance is provided by the CriticalProcess valve (CPA option), which enables users to check the integrity of
secondary containment.
♦ Vibration immunity is achieved using a mass-balanced sensor and Adaptive Digital Signal Processing with visual filtering.
Emerson-Rosemount 8800 MultiVariable Vortex Flow Meter
Specifications:-
Flow Meter Accuracy:
- ± 0.70% of mass flow rate in water using 8800 MultiVariable (MTA option).
- ± 2% of mass flow in steam using 8800 MultiVariable (MTA option).
- ± 1.3% of the rate at 30 psi through 2,000 psi in steam using 8800 MultiVariable (MPA option).
- ± 1.2% of the rate at 150 psi in steam using 8800 MultiVariable (MCA option).
- ± 1.3% of the rate at 300 psi in steam using 8800 MultiVariable (MCA option).
- ± 1.6% of the rate at 800 psi in steam using 8800 MultiVariable (MCA option)
- ± 2.5% of the rate at 2,000 psi in steam using 8800 MultiVariable (MCA option).
- ± 0.65% of volumetric rate for liquids (uncompensated).
- ± 1% of volumetric rate for gas and steam (uncompensated).
Output:
4-20 mA with HART 5 or 7 (MTA/MPA/MCA option).
4-20 mA with HART 5 or 7 and scalable pulse output (MTA/MPA/MCA option).
FOUNDATION Fieldbus ITK6 with 2 Analog Input blocks, 1 Backup Link Active Scheduler function block, 1 Integrator function block, and 1 PID function block(MTA option).
Modbus RS-485 with device status and 4 variables (MTA option).
Wetted Materials
Stainless Steel; 316 / 316L and CF3M.
Nickel Alloy; C-22 and CW2M.
High Temp Carbon Steel; A105 and WCB.
Low Temp Carbon Steel; LF2 and LCC.
Duplex; UNS S32760 and 6A.
Consult the factory for other wetted material.
Flange Options
ANSI Class 150 to 1500.
DIN PN 10 to PN 160.
JIS 10K to 40K.
Flanges are available in a variety of facings.
Consult the factory for additional flange ratings.
Process Temperature Limits : -330°F to 800°F (-200°C to 427°C).
Temperature Sensor Accuracy : ± 2.2°F (1.2°C)
Temperature Sensor Range : -40 to 800°F (-40 to 427°C).
Additional information
Product Model | Emerson – Rosemount 8800 Series |
---|---|
Brand | Emerson |