ACS CONTROL SYSTEM Ultrasonic Flowmeter FLOWCONT F630
MODEL:-F630
Magnetic inductive flowmeter, small or separate
✓ The suitable device for every application, with a wide range of options.
✓ Possible spared variation.
✓ ATEX-Authorization.
✓ Applications for hygiene.
✓ Mechanism for detecting errors.
Description
ACS CONTROL SYSTEM Ultrasonic Flowmeter FLOWCONT F630
Ultrasonic Flowmeter Flowcont F630
Function
The Flowcont® F630 is featured especially by his backlight illuminated display.
Many features can be set by the user:
- Contrast
- Configurable display
- Character size
- Number of lines
- Resolution of the display (number of fractional digits)
In the multiplex mode different display settings can be preconfigurated, that can be activated in succession.The “SensorMemory”, that is integrated in the sensor, makes the control of the assignment of measuring sensor and measuring transmitter unnecessary.After power on the auxiliary power the sensor data and the measuring place specific parameter will be loaded automatically. Thus, errors will be eliminated, the inauguration goes faster and safer and avoids problems.Diagnosis functions monitors the functionability of the Flowcont F630 and the engineering of the process. The limit values of the diagnosis parameter can be set in the operation field. At exceeding this limit values an alert occurs. For further analysis the diagnosis data can be read out by a modern infrared interface. This allows a higher productivity and avoids downtimes. The state messages are classified corresponding to the requirements of NAMUR NE107.In the case of an error in the display a diagnosis dependent message, that makes the error elimination much easier and faster. This offers a maximum safety in the process.
Ultrasonic Flowmeter Flowcont F630
Performance specifications-
Electrical properties
Supply power | AC: 100 … 230 V (-15 % / +10 %) AC: 24 V (-30 % / +10 %) DC: 24 V (-30 % / +30 %) Ripple: < 5 % |
Line frequency | 47 … 64 Hz |
Excitation frequency | 6 1/4 Hz, 7 1/2 Hz, 12 1/2 Hz, 15 Hz, 25 Hz, 30 Hz (50/60 Hz supply power) |
Power consumption | S ≤ 20 VA (flowmeter sensor incl. transmitter) |
Electr. connection | Screw terminals |
Inputs/outputs
Isolation of input/outputs–
The current output, digital outputs DO1 and DO2, and digital input are electrically isolated from the flowmeter sensor input circuit and from each other.
Mechanical properties
Compact design (transmitter mounted directly on the flowmeter sensor) | |
Housing | Cast aluminum, painted |
Paint | Paint coat 60 µm thick, RAL 9002 (light gray) |
Cable gland | Polyamide |
Design with external transmitter | |
Housing | Cast aluminum, painted |
Paint | Paint coat 60 µm thick, mid-section RAL 7012 (dark gray), front cover/rear cover RAL 9002 (light gray) |
Cable gland | Polyamide |
Weight | 4.5 kg (9.92 lb) |