Need help? Call us: 01326 708334, 01326 708335 or info@voltecbd.com
HTU218-1500/PT-M12
Ultrasonic sensor
Series: 200.
Operating principle: Diffuse reflection principle with background support...
Design: Cylindrical, 18 mm.
Operating range, max.: 0.15 ... 1.5 m.
Read more
Part no.: 50149542.
Technical Summary:
| Max. flow rate | 3300 L/h |
| Min. flow rate | 0.12 L/h |
| Max. flow rate | 872 USGPH |
| Min. flow rate | 0.03 USGPH |
| Drive speed control ratio | 3600:1 |
| Operating temperature range | 5 to 40 °C |
| Operating temperature range | 40 to 104 °F |
| Control types | EtherNet/IP™, Profibus®, Profinet®, Remote Analogue/Digital, RS485, SCADA |
| Drive standards | CE, cETLus, C-Tick, IRAM, NSF/ANSI 61 (for Marprene tubing and loadsure elements) |
| Drive ingress rating | IP66, NEMA 4X |
| Drive power supply | 100-120 V/200-240 V 1ph 50/60 Hz 350 VA |
| Compatible tubing bore size | 9.6, 12.7, 15.9, 19, 25.4 mm |
Technical Summary
| Max. flow rate | 18 L/min |
| Min. flow rate | 0.001 L/min |
| Max. flow rate | 301 USGPH |
| Min. flow rate | 0.02 USGPH |
| Drive speed control ratio | 2650:1 |
| Operating temperature range | 5 to 40 °C |
| Operating temperature range | 41 to 104 °F |
| Control types | EtherNet/IP™, Profibus®, Profinet®, Remote Analogue/Digital, RS232, RS485, SCADA |
| Drive standards | CE, cETLus, C-Tick, IRAM, NSF/ANSI 61 (for Marprene tubing and loadsure elements) |
| Drive ingress rating | IP31, IP66, NEMA 2, NEMA 4X |
| Drive power supply | 100-120 V/200-240 V 1ph 50/60 Hz 250 VA |
| Compatible tubing bore size |
Technical Summary:
| Max. flow rate | 3500 ml/min |
| Min. flow rate | 0.004 ml/min |
| Max. flow rate | 56 USGPH |
| Min. flow rate | 0 USGPH |
| Drive speed control ratio | 2200:1 |
| Operating temperature range | 5 to 40 °C |
| Operating temperature range | 40 to 104 °F |
| Control types | EtherNet/IP™, Profibus®, Profinet®, Remote Analogue/Digital, RS232, RS485, SCADA |
| Drive standards | CE, cETLus, C-Tick, IRAM, NSF/ANSI 61 (for Marprene tubing and loadsure elements), RoHS |
| Drive ingress rating | IP31, IP66, NEMA 2, NEMA 4X |
| Drive power supply | 115/230 V 1ph 50/60 Hz 135 VA |
| Compatible tubing bore size | 0.5, 1.6, 3.2, 4.8, 6.4, 8, 9.6 mm |
Series:-RSL 400
Application:-
♦ Mobile danger zone guarding.
♦ Mobile side guarding.
♦ Stationary access guarding.
♦ Stationary danger zone guarding.
Part no.: 53800207
WATSON MARLOW 300 SERIES CASED PUMP TECHMICAL SUMMERY:
| Max. flow rate | 3000 ml/min |
| Min. flow rate | 0.002 ml/min |
| Speed control ratio | 133:1, 147:1, 200:1, 27:1, 300:1 |
| Operating temperature range | 5 to 40 °C |
| Operating temperature range | 40 to 104 °F |
| Drive standards | CE, cETLus |
| Drive ingress rating | IP31 |
| Drive power supply | 1ph, 100-120 V, 220-240 V 50/60 Hz, 100 VA |
| Compatible tubing bore size | 0.13, 0.19, 0.25, 0.38, 0.5, 0.63, 0.76, 0.8, 0.88, 1.02, 1.14, 1.29, 1.42, 1.52, 1.6, 1.65, 1.85, 2.05, 2.29, 2.54, 2.79, 3.2, 4.8, 6.4, 8 mm |
TECHNICAL SUMMERY OF WATSON MARLOW 100 SERIES CASED PUMP:
| Max. flow rate | 190 ml/min |
| Min. flow rate | 0.0001 ml/min |
| Max. flow rate | 3.04 USGPH |
| Min. flow rate | 0.00002 USGPH |
| Max. operating pressure | 2 bar |
| Max. operating pressure | 30 psi |
| Speed control ratio | 100:1, 1000:1, 200:1, 2000:1, 32:1, 320:1 |
| Operating temperature range | 5 to 40 °C |
| Operating temperature range | 40 to 104 °F |
| Standards | CE, cETLus |
| Ingress rating | IP31, NEMA 2 |
| Power supply | Supplied with 24 VDC mains transformer plug (range 90-264 VAC 47-63 Hz) which comes with multi-country adaptors |
TECHMICAL SUMMERY FOR WATSON MARLOW Quantum single-use bioprocessing pumps:
| Min. flow rate | 5.33 ml/min |
| Max. flow rate | 20 L/min |
| Max. operating pressure | 3 bar |
| Speed control ratio | 4000:1 |
| Operating temperature range | 5 to 30 °C |
| Operating temperature range | 41 to 86 °F |
| Control types | Remote Analogue/Digital |
| Standards | CE, cETLus, IEC 61010-1 |
| Ingress rating | IP66, NEMA 12/13 |
| Power supply | 100-120 V/200-240 V 1ph 50/60 Hz 250 VA |
INDUCTIVE SENSOR-
Cylindrical inductive switch, working range Sa: 0-1.6 mm, 35 m length, 2000 mm cable connection,
one output with typically open PNP switching, supply voltage: 10-30 V DC, embedded installation, and IP 67 protection.
Part no.: 50146967. The laser distance sensor is an optical distance sensor that operates according to the triangulation mea- surement principle.
The sensor consists of the following components:-
Read more
- Transmitter: laser spot.
- Receiver.
- White OLED display.
- Control panel with control buttons.
- Status LEDs.
Qdos Chemical Metering Pumps:
Delivering flow rates that remain constant right up to 7 bar Qdos chemical metering pumps give users a unique advantage over diaphragm metering pumps. Qdos pumps offer long maintenance intervals - reducing the impact of process downtime and lowering the overall cost of ownership. The GWA-250-U0 dual limit value switch enables the parallel configuration of up to two switching
levels for continuous measurements without the installation of extra measurement equipment.
♦ The key coding switch allows for the simplest switching point change.
♦ Switchable input.
♦ Powering integrated converters.
Read more
Galvanic isolation, universal signal converter, and standard signal conversion.
♦ Installing is simple.
♦ Power supply that is universal.
♦ 3x isolated galvanic.
Read more
Pipe installation data logger with GSM data transmission, powered by a battery or an AC adapter.
♦ Installing in a 2" tube.
♦ Safety overflow.
♦ Using the most effective source for communication.
Read more
Hydrostatic level measurement using a level sensor with a 22mm diameter and a capacitive ceramic measuring cell
with an RS485 Modbus-RTU output signal.
♦ Reliable and efficient ceramic cell.
♦ Possible integrated temperature measurement.
♦ Low consumption of energy.
Read more
Independent data logger and IOT Gateway
♦Power supply options come in a variety of forms. ♦Using the most effective source for communication. ♦with up to 7 sensors and 12 measurement types.A robust, Ø78 mm, programmable hollow shaft angle transmitter
detects the angular position of a shaft without making contact with it and
transforms the information into an impressed direct current proportional to the measured value.
Features:-
-
Hollow-shaft angle-of-rotation transmitter with a tough, weatherproof design.
-
Highest level of electrical and mechanical safety.
-
Advanced capacitive scanning system.
-
Easy axis or shaft mounting.
-
Installing a continuous shaft.
-
Enduring, upkeep-free, and simple to install.
-
Shake- and vibration-resistant.
-
Keys and switches can be used to parameterize the measuring range, rotational direction, zero point, and characteristic curve (linear/V).
-
Analog output signal, 2-wire connector, 4...20 mA.
-
Independently adjustable zero point and span.
-
Due to the capacitive scanning mechanism, the absolute position is immediately available after turning on.
An angle proportional inclination is transformed into a DC signal using the KINAX N702.
An analog current change (4–20 mA) that represents the output signal is accessible.
There is little mechanical wear on the pendulum from the sensor, which is non-contact.
Features:-
- Magnetoresistive inclination transducer
- Digital interfaces CANopen
- Robust aluminum housing
- Protection class IP66
- Oil damped pendulum
- Pendulum shaft without mechanical stop
Standard Pressure Transmitters
The pressure transmitters of the 21Y series are incredibly robust to environmental
impacts since they lack an internal seal and have a high insulation voltage of 300 VDC.
An intricate compensation circuit allows for the specification of a small total error band.
Electrical connections and pressure connections come in a variety of options.
SIMILAR SERIES:-
- Series 21PY.
- Series 21C.
- Series 23SY.
- Series 25Y.
KOBOLD room thermostats are suitable for industrial plants, greenhouses, and warehouses, and also for monitoring the maximum temperature in switchgear cabinets and relay stations. Room thermostats are supplied with TER-H 1 wall brackets.
Switching range:- -20 ... +20 ... +80 ... +130°C, adjustable. Material:-aluminum (housing). copper, brass, or stainless steel (probe). Micro switch:- SPDT max. 250 VAC, 8 (5) A at 250 VAC, 8 A at 24 VDC. Pitot tube sensors are classified as differential pressure sensors for flow measurement.
Connection: G1 ... G 1½, 1 ... 1½" NPT, DN25 ... 80, ANSI 1 ... 3".
Material: stainless steel.
pmax: 400 bar.
tmax: 1175 °C.
Probe length: 50 ... 8000 mm (2" ... 600").
Read more
ELECTROMAGNETIC FLOWMETER
- High accuracy (±0.2%), with CT approvals (OIML R49, MI-001)
- 0D/0D installation acc. to MID MI-001 and OIML R49 accuracy class 1
- Flange: DN25…3000 / 1…120", max. PN40 / ASME Cl 300
- 3 x 4…20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET
VU 570 - Vortex ultrasonic sensor for flow measurement
Independent of the gas composition, flow meters for technical gases and mixed gases.The VU 570 helps you keep an eye on, control, and minimize your usage while
improving sustainability. One sensor can be used to track your consumption
of various gas compositions and gas types.
FA 500 - Dew point sensor with integrated display and alarm relay
- Dew point sensor FA 500 from -80 to 20°Ctd.
- For refrigeration, membrane, and desiccant dryers, the FA 500 is the perfect dew point sensor with an integrated display and warning relay.
FA 550 - Dew point sensor in robust die-cast aluminum housing
✓Robust dew point sensor for gases and compressed air
✓ The Dew point FA 550 is perfectly suited for measuring dew points outside and reliably does so even in punishing industrial settings.
✓Dew point measurement after adsorption dryers, membrane dryers, or refrigeration dryer in compressed air systems.
Read more
Pressure transmitter/pressure switch for typical applications with data memory Monitoring of gases, vapors, liquids, and dust at absolute or relative pressures.
With ceramic front-flush or internal diaphragm
With TFT-display, 4-20mA or 0-10V output and up to 4 pnp switching outputs.
♦ Color display and full text programming.
♦ Ceramic cell that is precise and stable.
♦ 500 000 measuring point data logger.
Read more
Ultrasonic flowmeter
✓ Suitable for use with both conductive and non-conductive liquids. ✓ Due to the seal-free sensor, there is high process safety. ✓ The measurement tube can move easily.MODEL:-F630
Magnetic inductive flowmeter, small or separate ✓ The suitable device for every application, with a wide range of options. ✓ Possible spared variation. ✓ ATEX-Authorization. ✓ Applications for hygiene. ✓ Mechanism for detecting errors.Multivariable, simple, and user-friendly smart magmeter for utilities
♦ Decent design.
♦ Enclosed control panel.
♦ Parameterization is possible via Bluetooth.
Flow switch and transmitter for basic industrial, sanitary, and aseptic applications.
♦ Applications for hygiene.
♦ Compact design.
♦ Speed of response.
Read more
♦ Installing a simple pressurized system is possible.
♦ High precision.
♦ Very little pressure drop.
Read more
♦ Quick response.
♦ Operator comfort is improved through display and operation on-site.
♦ Wireless.
Read more
♦Comprising a measurement portion, compressed air, and gas meter.
♦ Simple and affordable installation.
♦ Owing to its excellent accuracy, it is suitable for measuring leaks.
Read more
Special features:-
• Min/max value memory and display.
• Hold function.
• Taring function for weighing applications.
• Customer-specific linearization (40 value pairs or polynomial).
• Timer function.
• Four limit value monitoring functions.
• Individual user level.
• Separate application using structured text (ST code; option).
• Math and logic function (option).
• Fast wiring through Push-In technology.
• Analog output (option).
• RS485 or Ethernet interface (option).
• Additional analog and digital inputs via interface.
Read more
The JUMO di 308 signaling device shows standard signals in "simple text" as well as temperatures in °C or °F. The fundamental device is pre-configured with a voltage supply for two-wire transmitters, 1 analog input, 2 binary inputs, 2 relay outputs, and 2 logic outputs.
Read more
Operation is made simple with the JUMO LOGOSCREEN 700 paperless recorder's intuitive, icon-based operation and display approach. It is flexible and available in a variety of forms for process data gathering.
Read more
- Dependable optical measuring of distance with great ranges up to 6 m.
- There are two switching outputs, one of which can be programmed to be an analog output.
- window and a scalable measuring range.
- For the requirements of the automotive sector, laser protection class 1.
- Great value for the money.
1489 Thermal-Magnetic Circuit Breakers
Bulletin 1489-M Thermal-magnetic Circuit Breakers are UL 489 Listed for branch circuit protection in the United States and Canada, and they are certified as Miniature Circuit Breakers for IEC applications. These circuit breakers are ideal for extreme ambient conditions, feature fast breaking time, and superior shock and vibration resistance.
Read more
LOGO! 12/24RCE, a logic module with display, voltage supply: 12/24V DC/relay, 8DI (Digital Inputs), 4 of which can be used as AI (Analogue Inputs), 4DO (Digital Outputs), memory: 400 blocks, expandable, Ethernet, integral web server, data logging, standard micro SD card, for LOGO! SOFT COMFORT from version 8, older projects executable.
TCN4S-24R
- Display method : 4-digit 7-segment LED
- Control method : ON/OFF, P, PI, PD, PID
- Input specification : Thermocouple: K(CA), J(IC), T(CC), R(PR), S(PR), L(IC) RTD: DPt100Ω, Cu50Ω
- Sampling cycle : 100ms
- Control output : Relay(250VAC~ 3A) or SSR drive(12VDC ) [ON/OFF]
- Power supply : 100-240VAC~ 50/60Hz
Product ID: 751102.
PNOZsigma safety relay (standalone), inputs: 1-channel wiring without detection of shorts across contacts, manual/automaticstart, outputs: 3 N/O, 1 N/C, 1 SC, UB 24 V DC, width: 17.5 mm, plug-in spring-loaded terminals, monitoring of E-STOP, safety gates.
Read more
SIMATIC DP, Electronics module for ET 200S, 2 AO I 15 mm width, +/-20mA; 13 bit+sign, 4..20mA; 13 bit Cycle time less than 1 ms with SF LED (group fault).
Read more
Danfoss FC 51 Micro Drive 0.37KW 3ph 400V Inverter
Model: FC-051PK37T4E20H3XXCXXXSXXX
Made By Danfoss in China
Read more
Danfoss FC 51 Micro Drive 0.37KW 3ph 400V Inverter
Danfoss 0.37KW VLT Micro Drive
Model: FC-051PK37T4E20H3XXCXXXSXXX
I/P: 3X380-480VAC 50/60Hz 1.9/1.7A
O/P: 3X380-480VAC 50/60Hz 1.2/1.1A
Made By Danfoss in China
Specifications
Attribute |
Value |
For Use With |
SIMATIC S7-200 Series |
Manufacturer Series |
S7-200 |
Number of Inputs |
14 |
Number of Digital Inputs |
14 |
Output Type |
Analogue, Digital, Transistor |
Voltage Category |
20.4 → 28.8 V dc |
Input Type |
Analogue, Digital |
Number of Digital Outputs |
10 |
Number of Outputs |
10 |
Communication Port Type |
RS485 |
Program Capacity |
12 kB |
Programming Language Used |
AWL, FUP, Ladder Logic |
Mounting Type |
Rack Mount |
Programming Interface |
Computer, SIMATIC PG/PC |
Output Current |
750 mA |
Number of Communication Ports |
1 |
Battery Backup |
Yes |
Length |
80mm |
Memory |
12 (Program Memory) kB, 8 (Data Memory) kB |
Width |
120.5mm |
Dimensions |
80 x 120.5 x 62 mm |
Maximum Operating Temperature |
+45°C |
Minimum Operating Temperature |
0°C |
Depth |
62mm |
FA-COM PLC: Analogue I/O Module
| Series | MELSEC-F SERIES |
|---|---|
| Type | FX3U |
| Power Supply (V) | 24 |
| Current Type | DC |
| Occupied I/O Points on PLC | 8 |
| Integrated Analogue Outputs | 4 |
| Output Voltage Range (V) | 0-10 |
| Output Current Range (mA) | 4-20 |
| Min. Ambient Temperature (°C) | 0 |
| Max. Ambient Temperature (°C) | 55 |
- Manufacturer : DELTA
- Product No. : DVP32ES200R
- Product Type : Programmable Logic Controller DVP Series
- DVP-ES2 Series Standard PLC
- Power Supply : 100 ~ 240 V
- Output Method : Relay
- Inputs : 16
- Outputs : 16
- Display method : 4-digit 7-segment LED.
- Control method : ON/OFF, P, PI, PD, PID.
- Input specification : Thermocouple: K(CA), J(IC), E(CR), T(CC), B(PR), R(PR), S(PR), N(NN), C(TT), G(TT), L(IC), U(CC), Platinel II. RTD: DPt100Ω, DPt50Ω, JPt100Ω, Cu100Ω, Cu50Ω, Nikel 120Ω. Analog: 0-100mV, 0-5V, 1-5V, 0-10V. 0-20mA, 4-20mA.
- Sampling cycle : 50ms.
- Control output 1 : Current(DC0/4-20mA) or SSR drive(11VDC
) [ON/OFF].
- Option output : Alarm 1, RS485 comm.
- Power supply : 100-240VAC~ 50/60Hz.
- Protection structure : IP65(front panel).
SITOP DC UPS module 24 V/15 A uninterruptible power supply without interface input: 24 V DC/16 A output: 24 V DC/15 A.
Read more
Voltec Engineering Limited
Automation and control products are the focus of VOLTEC ENGINEERING LIMITED. In the area of comprehensive industry solutions for alteration, upgrading, and new construction projects, VOLTEC ENGINEERING LIMITED is a one-stop solution provider.
Need Help?
01326 708335
01329 727092
Customer Service