- Diameter: Ø 8mm
- Sensing Range Sn : 4mm
- Switching Output: PNP/NC
- Installation Type: Non-flush
- Diameter : Ø 6.5mm
- Sensing Range Sn : 4mm
- Switching Output : NPN/NO
- Installation Type : Non-flush
- Diameter : Ø 18mm
- Sensing Range Sn : 8mm
- Switching Output : NPN/NC
- Installation Type : Flush
- Diameter : Ø 8mm
- Sensing Range Sn : 0 mm ... 4 mm
- Output Function : Analog
- Installation Type : Quasi-flush
- Diameter: Ø 30mm
- Sensing Range Sn : 20mm
- Switching Output: PNP/Complementary
- Installation Type: Non-flush
Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 | |
Measuring range |
|
Electrical design | PNP/NPN |
- Electrical Design : PNP/NPN; (Automatic Load Detection PNP/NPN)
- Output Function : Normally Open / Normally Closed; (Selectable)
- Sensing Range [mm] : 20
- Communication Interface : IO-Link
- Sensing Range: 15mm
- Electrical Design PNP/NPN
- Output Function: Normally Open/Normally Closed(Selectable)
- Sensing Range Sn: 5mm
- Switching Output: NPN/NO
- Installation Type: Non-flush
- Enclosure Rating: IP67
- Sensing Range Sn: 20mm
- Switching Output: PNP/NO
- Installation Type: Flush
- Enclosure Rating: IP67, IP68, IP69K
- Diameter: Ø 12mm
- Sensing Range Sn : 10mm
- Switching Output: PNP/NO
- Installation Type: Non-flush
- Switching Output: NPN
- Supply Voltage: 10 V DC … 30 V DC
- Ripple: ≤ 5 Vpp
- Current Consumption: < 80 mA
- Switching Frequency: 10 kHz
- Response Time: 50 µs
- Switching Output: PNP
- Supply Voltage: 10 V DC ... 30 V DC
- Ripple: ≤ 5 Vpp
- Current Consumption: < 80 mA
- Switching Frequency: 10 kHz
- Response Time: 50 µs
- 10Nm,
- 24Vac/Vdc
- Modulating control
- Non-Spring return Voltage Feedback Signal and without aux
- Switch
The speed and direction of automated guided vehicles (AGVs) are controlled by motor feedback systems. SKS/SKM36 or SRS/SRM50 solutions offer a secure signal.
Read more
Flush Pressure Transmitter PM1705
PL5400, PL5401, PL5402, PL5412, PL5423, PY2033, PL1502, PL1503, PL1504, PL1506, PL1512, PL1514, PL1515, PL1523, PL1543
Transmitters for Mobile Applications
PT500E, PT5500, PT560E, PT5560, PT501E, PT5501, PT504E, PT5504, PT503E, PT5503, PT502E, PT502E, PT5502, PT5600, PT700E, PT5700, PT701E, PT5701, PT704E, PT5704, PU500E, PU8500, PT703E, PT702E, PT5604, PU501E,
PU5703, PU8502, PU8503, PU8701, PU8702, PU8712, PU5701, PU5604, PU1732, PU5602, PU5660, PU5700, PU5702, PU5704, PU5760, PU5760, PU1760, PT9551, PT9550, PT5043,PT5060
Type PN / PE with Digital Display
PN7071, PN2094, PN 7092, PN7094, PN7093,PN3094, PN7070, PN3071, PN2071, PN2294, PN7294, PN3092, PN7096, PY9170, PN2696, PE2094, PE2099, PE2591
Read more
VersaFlow Magnetic Flowmeters are highly versatile, customizable and offer precise flow measurement for conductive liquids, pastes and slurries.
Electrical data:
Connection terminals: 0.14 ÷ 2.5 mm2 (AWG 26 ÷ 14)
Cable entry:Cable gland: M20x1.5 with cable sheath diameter 6÷12mm CONDUIT: NPTx½ o NPT3/4
Output activation delay: Rods free → Rods covered: c.a. 1 sec Rods covered → Rods free c.a. 1... 2 sec
Detection fuctions FSH/FSL: Settable on the circuit with selector switch
Vibration frequency: [Hz] 200 c.a.
Over voltage category: II
Pollution degree: 2 (inside housing)
Operative Conditions:
Ambient temperature: [°C] -40 ÷ +60
Process temperature-Tc: [°C] -40 ÷ +150
Ventilation:Ventilation is not required
Min. powder density: [g/l] Setting A : c.a. 150 - Setting B : c.a. 30
Features of bulk material: No strong tendency to cake or deposit. Max grain size 8 mm
Max. mechanical load: [N] 500 laterally on vibrant rods
Max. process pressure: [Bar] 16
Vibration: c.a. 200
Relative humidity: 0 ÷ 100%, suitable for outdoor use
Altitude: [m] max 2.000
Read more
- Dependable optical measuring of distance with great ranges up to 6 m.
- There are two switching outputs, one of which can be programmed to be an analog output.
- window and a scalable measuring range.
- For the requirements of the automotive sector, laser protection class 1.
- Great value for the money.
The W12L-2 series of photoelectric sensors features laser technology that is optimally designed for individual applications. These sensors provide reliable object detection, fast response times and are enclosed in a rugged metal housing, which is ideal for use in all types of industrial applications.
At a glance-
• Best-in-class retro-reflective laser performance in a metal housing.
• Teflon® coating available.
• Precise autocollimation optics.
• Adjustable focus on retro-reflective sensors.
• High switching frequency of 2.5 kHz.
• Connection via cable or rotatable connector.
• Mounting options with through holes, blind holes, oblong holes and dovetail.
• Laser protection class 1 or 16.
Read more
- Housing: Standard design.
- Sensing range Sn: 6 mm.
- Installation type: Quasi-flush.
- Electrical wiring: DC 3-wire.
- Switching output: PNP.
- Output function: NO.
- Connection type: Male connector M12, 4-pin.
- In order to ensure quality, completeness, position, and existence.
- Verification of contours without regard to orientation.
- Independent gadget with built-in lighting.
- User-friendly, intuitive handling.
- An Ethernet interface with high throughput for data transmission.
Measuring the oxygen in the process can be quite simple. The TRANSIC100LP from SICK is the rugged transmitter that uses Tunable Diode Laser Spectroscopy (TDLS) to measure O2 reliably. A technology more common in the world of high-tech analysis is now being used in a field instrument: at an attractive price, easy installation, a long life, low maintenance, and suitable for use in potentially explosive atmospheres.
Read more

Voltec Engineering Limited
Automation and control products are the focus of VOLTEC ENGINEERING LIMITED. In the area of comprehensive industry solutions for alteration, upgrading, and new construction projects, VOLTEC ENGINEERING LIMITED is a one-stop solution provider.
Need Help?
01326 708335
01329 727092
Customer Service
© 2023 Voltec Engineering Ltd. | Design & Developed by mPair Technologies Ltd.