- Diameter: Ø 8mm
- Sensing Range Sn : 4mm
- Switching Output: PNP/NC
- Installation Type: Non-flush
- Diameter : Ø 6.5mm
- Sensing Range Sn : 4mm
- Switching Output : NPN/NO
- Installation Type : Non-flush
- Diameter : Ø 18mm
- Sensing Range Sn : 8mm
- Switching Output : NPN/NC
- Installation Type : Flush
- Diameter : Ø 8mm
- Sensing Range Sn : 0 mm ... 4 mm
- Output Function : Analog
- Installation Type : Quasi-flush
- Diameter: Ø 30mm
- Sensing Range Sn : 20mm
- Switching Output: PNP/Complementary
- Installation Type: Non-flush
- Sensing Range Sn: 5mm
- Switching Output: NPN/NO
- Installation Type: Non-flush
- Enclosure Rating: IP67
- Sensing Range Sn: 20mm
- Switching Output: PNP/NO
- Installation Type: Flush
- Enclosure Rating: IP67, IP68, IP69K
- Diameter: Ø 12mm
- Sensing Range Sn : 10mm
- Switching Output: PNP/NO
- Installation Type: Non-flush
- Switching Output: NPN
- Supply Voltage: 10 V DC … 30 V DC
- Ripple: ≤ 5 Vpp
- Current Consumption: < 80 mA
- Switching Frequency: 10 kHz
- Response Time: 50 µs
- Switching Output: PNP
- Supply Voltage: 10 V DC ... 30 V DC
- Ripple: ≤ 5 Vpp
- Current Consumption: < 80 mA
- Switching Frequency: 10 kHz
- Response Time: 50 µs
- 10Nm,
- 24Vac/Vdc
- Modulating control
- Non-Spring return Voltage Feedback Signal and without aux
- Switch
- Connection of additional universal alarm inputs
- Adding free inputs for display and supervision
- Event logging (e.g. legionella function)
- Additional time programs (ON / OFF) for basic functions
- Calculation of enthalpy, enthalpy differential, absolute humidity, dewpoint and wet bulb temperature
- Logic function blocks for switching on / off depending on different conditions
- Lead / lag control of pumps, fans, motors, etc., with automatic changeover
- Step switch with linear, binary or flexible functionality
The speed and direction of automated guided vehicles (AGVs) are controlled by motor feedback systems. SKS/SKM36 or SRS/SRM50 solutions offer a secure signal.
Read more
VersaFlow Magnetic Flowmeters are highly versatile, customizable and offer precise flow measurement for conductive liquids, pastes and slurries.
- SIMATIC HMI TP900 Comfort.
- Comfort Panel.
- Touch operation.
- 9 "TFT display (widescreen).
- 16 million Colours.
- PROFINET interface.
- MPI/PROFIBUS-DP interface.
- Configuration memory: 12 MByte.
- Windows CE 6.0 (Microsoft-Support incl. Security updates discontinued) configurable from WinCC Comfort V11.
The W12L-2 series of photoelectric sensors features laser technology that is optimally designed for individual applications. These sensors provide reliable object detection, fast response times and are enclosed in a rugged metal housing, which is ideal for use in all types of industrial applications.
At a glance-
• Best-in-class retro-reflective laser performance in a metal housing.
• Teflon® coating available.
• Precise autocollimation optics.
• Adjustable focus on retro-reflective sensors.
• High switching frequency of 2.5 kHz.
• Connection via cable or rotatable connector.
• Mounting options with through holes, blind holes, oblong holes and dovetail.
• Laser protection class 1 or 16.
Read more
*** spare part *** SIMATIC HMI KTP600 Basic Color DP, Basic Panel, key/touch operation, 6" TFT display, 256 colors, MPI/PROFIBUS DP interface, configurable as of WinCC flexible 2008 SP2 Compact/ WinCC Basic V11/ STEP 7 Basic V11, contains open-source software, which is provided free of charge see enclosed CD.
Read more
- Housing: Standard design.
- Sensing range Sn: 6 mm.
- Installation type: Quasi-flush.
- Electrical wiring: DC 3-wire.
- Switching output: PNP.
- Output function: NO.
- Connection type: Male connector M12, 4-pin.
• Pressure-linear characteristic with selectable pressure measuring range.
• Operating voltage AC 24 V or DC 13.5…33 V.
• Output signal DC 0...10 V.
• Zero-point adjustment.
• Simple and fast mounting thanks to integrated mounting brackets in the housing.
• Maintenance free.
• Calibrated and temperature-compensated measuring signal.
• Supplied with tubing connection set.
Read more
SIRIUS, COMPACT STARTER, DIRECT STARTER. 690 V, 24 V DC, 3 ... 12 A, IP20, CONN. MAIN CIRCUIT: SCREW TERMINAL, CONN. CONTROL CIRCUIT: SCREW TERMINAL.
Read more
Measuring the oxygen in the process can be quite simple. The TRANSIC100LP from SICK is the rugged transmitter that uses Tunable Diode Laser Spectroscopy (TDLS) to measure O2 reliably. A technology more common in the world of high-tech analysis is now being used in a field instrument: at an attractive price, easy installation, a long life, low maintenance, and suitable for use in potentially explosive atmospheres.
Read more

Voltec Engineering Limited
Automation and control products are the focus of VOLTEC ENGINEERING LIMITED. In the area of comprehensive industry solutions for alteration, upgrading, and new construction projects, VOLTEC ENGINEERING LIMITED is a one-stop solution provider.
Need Help?
01326 708335
01329 727092
Customer Service
© 2023 Voltec Engineering Ltd. | Design & Developed by mPair Technologies Ltd.