Need help? Call us: 01326 708334, 01326 708335 or info@voltecbd.com
- Switching Output: PNP
- Output Function: Complimentary
- Switching Mode: Light/Dark Switching
- Dia: 18mm , Connection : M12
- Metal Housing
- Diameter: Ø 8mm
- Sensing Range Sn : 4mm
- Switching Output: PNP/NC
- Installation Type: Non-flush
- Diameter : Ø 6.5mm
- Sensing Range Sn : 4mm
- Switching Output : NPN/NO
- Installation Type : Non-flush
- Diameter : Ø 18mm
- Sensing Range Sn : 8mm
- Switching Output : NPN/NC
- Installation Type : Flush
- Diameter : Ø 8mm
- Sensing Range Sn : 0 mm ... 4 mm
- Output Function : Analog
- Installation Type : Quasi-flush
- Diameter: Ø 30mm
- Sensing Range Sn : 20mm
- Switching Output: PNP/Complementary
- Installation Type: Non-flush
- Sensing Range Sn: 5mm
- Switching Output: NPN/NO
- Installation Type: Non-flush
- Enclosure Rating: IP67
- Sensing Range Sn: 20mm
- Switching Output: PNP/NO
- Installation Type: Flush
- Enclosure Rating: IP67, IP68, IP69K
- Diameter: Ø 12mm
- Sensing Range Sn : 10mm
- Switching Output: PNP/NO
- Installation Type: Non-flush
- Switching Output: NPN
- Supply Voltage: 10 V DC … 30 V DC
- Ripple: ≤ 5 Vpp
- Current Consumption: < 80 mA
- Switching Frequency: 10 kHz
- Response Time: 50 µs
- Switching Output: PNP
- Supply Voltage: 10 V DC ... 30 V DC
- Ripple: ≤ 5 Vpp
- Current Consumption: < 80 mA
- Switching Frequency: 10 kHz
- Response Time: 50 µs
JUMO AQUIS 500 CR
You can measure and control the widest range of electrochemical measurands in liquids with JUMO transmitters and controllers. Reliably control conductivity, redox potential, and pH value as well as the concentration of ammonia, bromine, chlorine, chlorine dioxide, dissolved oxygen, caustic soda, hydrogen peroxide, ozone, peracetic acid, and nitric acid.
Read more
The speed and direction of automated guided vehicles (AGVs) are controlled by motor feedback systems. SKS/SKM36 or SRS/SRM50 solutions offer a secure signal.
Read more
Special features:-
• Min/max value memory and display.
• Hold function.
• Taring function for weighing applications.
• Customer-specific linearization (40 value pairs or polynomial).
• Timer function.
• Four limit value monitoring functions.
• Individual user level.
• Separate application using structured text (ST code; option).
• Math and logic function (option).
• Fast wiring through Push-In technology.
• Analog output (option).
• RS485 or Ethernet interface (option).
• Additional analog and digital inputs via interface.
Read more
The JUMO di 308 signaling device shows standard signals in "simple text" as well as temperatures in °C or °F. The fundamental device is pre-configured with a voltage supply for two-wire transmitters, 1 analog input, 2 binary inputs, 2 relay outputs, and 2 logic outputs.
Read more
Operation is made simple with the JUMO LOGOSCREEN 700 paperless recorder's intuitive, icon-based operation and display approach. It is flexible and available in a variety of forms for process data gathering.
Read more
TCN4S-24R
- Display method : 4-digit 7-segment LED
- Control method : ON/OFF, P, PI, PD, PID
- Input specification : Thermocouple: K(CA), J(IC), T(CC), R(PR), S(PR), L(IC) RTD: DPt100Ω, Cu50Ω
- Sampling cycle : 100ms
- Control output : Relay(250VAC~ 3A) or SSR drive(12VDC ) [ON/OFF]
- Power supply : 100-240VAC~ 50/60Hz
- Display method : 4-digit 7-segment LED.
- Control method : ON/OFF, P, PI, PD, PID.
- Input specification : Thermocouple: K(CA), J(IC), E(CR), T(CC), B(PR), R(PR), S(PR), N(NN), C(TT), G(TT), L(IC), U(CC), Platinel II. RTD: DPt100Ω, DPt50Ω, JPt100Ω, Cu100Ω, Cu50Ω, Nikel 120Ω. Analog: 0-100mV, 0-5V, 1-5V, 0-10V. 0-20mA, 4-20mA.
- Sampling cycle : 50ms.
- Control output 1 : Current(DC0/4-20mA) or SSR drive(11VDC
) [ON/OFF].
- Option output : Alarm 1, RS485 comm.
- Power supply : 100-240VAC~ 50/60Hz.
- Protection structure : IP65(front panel).
- Display method: 4-digit 7-segment LED.
- Control method: ON/OFF control, P, PI, PD, PIDF, PIDS control.
- Input specification : Thermocouple: K(CA), J(IC), E(CR), T(CC), R(PR), S(PR), N(NN), W(TT) RTD: DPt100Ω, JPt100Ω
- Analog: 1-5VDC , 0-10VDC , DC4-20mA..
- Sampling cycle: 500ms.
- Control output : Relay(250VAC~ 3A).
- Power supply : 100-240VAC~ 50/60Hz.
The W12L-2 series of photoelectric sensors features laser technology that is optimally designed for individual applications. These sensors provide reliable object detection, fast response times and are enclosed in a rugged metal housing, which is ideal for use in all types of industrial applications.
At a glance-
• Best-in-class retro-reflective laser performance in a metal housing.
• Teflon® coating available.
• Precise autocollimation optics.
• Adjustable focus on retro-reflective sensors.
• High switching frequency of 2.5 kHz.
• Connection via cable or rotatable connector.
• Mounting options with through holes, blind holes, oblong holes and dovetail.
• Laser protection class 1 or 16.
Read more
Temp Control, 1/4 DIN, Zone PID, RS485, 100-240VAC; Fixed Control, 4 Alarm, Current/SSR Drive Out1&2, 1 CT+3 Digital Input,
Read more
- Housing: Standard design.
- Sensing range Sn: 6 mm.
- Installation type: Quasi-flush.
- Electrical wiring: DC 3-wire.
- Switching output: PNP.
- Output function: NO.
- Connection type: Male connector M12, 4-pin.
Core features
- Available in NEMA 1, 3R, 4, 4X, 12 enclosures for a broad range of application environments.
- Most common disconnect switches in stock and ship within 24 hours with QuikShip Everyday Service to meet project requirements.
- Multiple field-installed accessories enhance the enclosed disconnect switches to fit the desired application.
- UL 508 Listed for motor disconnect applications.
- 3- and 6-Pole UL 508 motor disconnect switches provide flexibility for single or dual motor applications.
- NEMA 4X 30A and 60A motor control disconnects.
Eaton Bussmann series CCP compact circuit protector, Compact Circuit Protector, 30 A, Single-pole, 20 lb-in, Class G, Screw with pressure plate, Front panel, 240 V.
Read more
Measuring the oxygen in the process can be quite simple. The TRANSIC100LP from SICK is the rugged transmitter that uses Tunable Diode Laser Spectroscopy (TDLS) to measure O2 reliably. A technology more common in the world of high-tech analysis is now being used in a field instrument: at an attractive price, easy installation, a long life, low maintenance, and suitable for use in potentially explosive atmospheres.
Read more

Voltec Engineering Limited
Automation and control products are the focus of VOLTEC ENGINEERING LIMITED. In the area of comprehensive industry solutions for alteration, upgrading, and new construction projects, VOLTEC ENGINEERING LIMITED is a one-stop solution provider.
Need Help?
01326 708335
01329 727092
Customer Service
© 2023 Voltec Engineering Ltd. | Design & Developed by mPair Technologies Ltd.