Mass flow: measurement error ±0.05 % (PremiumCal)
-
Medium temperature: -196 to 350 °C (-320 to 662 °F)
-
Nominal diameter: DN 8 to 250 (³⁄₈ to 10")
-
Compact dual-compartment housing with up to 3 I/Os
-
Backlit display with touch control and WLAN access
-
Remote display available
The Micropilot FMR62B provides high beam focusing for vessels with numerous internal fittings and is appropriate for free-space applications up to 80 meters.
Read more
Low-cost, high-flow solenoid valves for liquid, corrosive, and air/inert gas applications are part of the ASCO Series 210 series. The extremely reliable 2-way valves offer long service lives and little internal leakage thanks to their wide selection of pressure ratings, sizes, and durable materials. Car wash equipment, air compressors, pumps, laundry equipment, and industrial water control are a few examples of industrial usage.
Read more
FMU90, FDU95, FDU93, FDU92, FDU91, FMU95, FDU91F, FMU30, FMU40, FMU41, FMU42
FMU44, FMU90, FMU95, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL51B, FTL62, FTL51B
FTL64, FTLW23, QWX43, FMD71, FMD72, FMG50, FMP50, FMP51, FMP52, FMP53
FMP54, FMP55, FMP56, FMP57, FMR10, FMR20, FMR50, FMR57, FMU30, FMU40, FMU41, FMU42, FTL31
FTL33, FTL51C, FTL70, FTL80, FTM50, FWR30, FTW23, FTW33, FMI51, FTI51, FTI52, FTI55,FTI56, FTMI21
FMI52, FTC262, FTC260, FTI25
Read more
Proline Promag P 300 Electromagnetic Flowmeter, Proline Promag H 100 Electromagnetic Flowmeter, Proline Promag W 300 Electromagnetic Flowmeter,
Proline Promag W 400 Electromagnetic Flowmeter, Dosimag Electromagnetic Flowmeter, Proline Promag D 10 Electromagnetic Flowmeter,
Proline Promag E 100 Electromagnetic Flowmeter, Proline Promag H 200 Electromagnetic Flowmeter, Proline Promag H 300 Electromagnetic Flowmeter,
Proline Promag H 500 Electromagnetic Flowmeter, Proline Promag H 10 Electromagnetic Flowmeter, Proline Promag P 100 Electromagnetic Flowmeter,
Proline Promag P 200 Electromagnetic Flowmeter, Proline Promag P 500 Electromagnetic Flowmeter, Proline Promag P 10 Electromagnetic Flowmeter,
Proline Promag W 500 Electromagnetic Flowmeter, Proline Promag W 800 Electromagnetic Flowmeter, Proline Promag W 10 Electromagnetic Flowmeter,
Proline Promag W 500 Electromagnetic Flowmeter, Proline Promag 51W Electromagnetic Flowmeter, Proline Promag 55S Electromagnetic Flowmeter
Read more
Digital Combined pH/ORP Sensor Memosens CPS96D, Digital ORP Sensor Memosens CPS12E, Digital ORP Sensor Orbipore CPS92D, Digital pH Sensor Memosens CPS41E
Digital Combined pH/ORP Sensor Memosens CPS76D, Digital Conductivity Sensor Condumax CLS16D, Digital pH Sensor Memosens CPS61E
Digital Combined pH/ORP Sensor Memosens CPS16E, Digital non-glass pH Sensor Ceramax CPS341D, Digital pH Sensor Memosens CPS71E, Suspended Solids Sensor Turbimax CUS51D, Digital Conductivity Sensor Condumax CLS21D, Digital Oxygen Sensor Oxymax COS61D, Digital pH Sensor Memosens CPS31E, Digital ORP Sensor Ceraliquid CPS42D
Digital pH Sensor Memosens CPS91E, Digital pH Sensor Orbipac CPF81D, Digital Free Chlorine Sensor Memosens CCS51D, Digital Non-Glass pH SensorCeramax CPS341D
Immersion Assembly Dipfit CPA111, Memosens CPS77D
Read more
A pH sensor is a piece of scientific equipment that precisely calculates the acidity and alkalinity of water and other liquids. The majority of businesses, including power plants, pharmaceuticals, food and beverage, primary, chemicals, oil and gas, and wastewaters, depend on this equipment.
Read more
Specifications
Valve Actuation : Solenoid
- Body Material : Brass, Stainless Steel, Lead-free Brass, 316 stainless steel on request
- Media : Aggressive Liquids/Gases, Air, Inert Gas, Ammonia, Cryogenic, Fuel Oil, Hot Water, Light Oil, Liquid Propane Gas, Natural Gas, Oxygen, Steam, Vacuum, Water
- Pipe / Port Size : 1/2 "; 3/8 "; 3/4 "; 1 "; 1 1/4 "; 1 1/2 "; 2 "; 2 1/2 "
- Port Type : NPTF, G (ISO 228/1)
- Function : 2 way - 2/2 Normally Closed, 2 way - 2/2 Normally Open
- Flow : From 1.3 to 39 Kv , 1.5 to 45 Cv
- Voltage : 24 AC, 110 AC, 115 AC, 12 DC, 12 to 24 DC Voltage Ranging, 120 AC, 120 DC, 125 DC Battery Charging, 208 AC, 220 AC, 230 AC, 24 DC, 24 to 120 AC/DC Voltage Ranging, 240 AC, 240 DC - 50/60, Uncommon voltages available upon request.
- Max Differential / Max Operating Pressure: Vacuum to 24 bar, Vacuum to 350 psi
- Operating Environment : Corrosive, Hazardous, Indoor, Outdoor
Long-lasting inline flowmeter with a small, easily accessible transmitter.
Application-
• Measuring principle is characterized by a high operable flow range and direct mass flow measurement.
• Measurement of utility and process gases as well as gas mixtures in small line sizes Device properties.
• Inline version with DN 15 to 100 (½ to 4").
• Bidirectional measurement; high measuring performance.
• Patented drift-free sensor with SIL 2.
• Compact dual-compartment housing with up to 3 I/Os.
• Backlit display with touch control and WLAN access.
• Remote display available.
Read more
Technical Summary:
Max. flow rate | 3300 L/h |
Min. flow rate | 0.12 L/h |
Max. flow rate | 872 USGPH |
Min. flow rate | 0.03 USGPH |
Drive speed control ratio | 3600:1 |
Operating temperature range | 5 to 40 °C |
Operating temperature range | 40 to 104 °F |
Control types | EtherNet/IP™, Profibus®, Profinet®, Remote Analogue/Digital, RS485, SCADA |
Drive standards | CE, cETLus, C-Tick, IRAM, NSF/ANSI 61 (for Marprene tubing and loadsure elements) |
Drive ingress rating | IP66, NEMA 4X |
Drive power supply | 100-120 V/200-240 V 1ph 50/60 Hz 350 VA |
Compatible tubing bore size | 9.6, 12.7, 15.9, 19, 25.4 mm |
Technical Summary
Max. flow rate | 18 L/min |
Min. flow rate | 0.001 L/min |
Max. flow rate | 301 USGPH |
Min. flow rate | 0.02 USGPH |
Drive speed control ratio | 2650:1 |
Operating temperature range | 5 to 40 °C |
Operating temperature range | 41 to 104 °F |
Control types | EtherNet/IP™, Profibus®, Profinet®, Remote Analogue/Digital, RS232, RS485, SCADA |
Drive standards | CE, cETLus, C-Tick, IRAM, NSF/ANSI 61 (for Marprene tubing and loadsure elements) |
Drive ingress rating | IP31, IP66, NEMA 2, NEMA 4X |
Drive power supply | 100-120 V/200-240 V 1ph 50/60 Hz 250 VA |
Compatible tubing bore size |
Technical Summary:
Max. flow rate | 3500 ml/min |
Min. flow rate | 0.004 ml/min |
Max. flow rate | 56 USGPH |
Min. flow rate | 0 USGPH |
Drive speed control ratio | 2200:1 |
Operating temperature range | 5 to 40 °C |
Operating temperature range | 40 to 104 °F |
Control types | EtherNet/IP™, Profibus®, Profinet®, Remote Analogue/Digital, RS232, RS485, SCADA |
Drive standards | CE, cETLus, C-Tick, IRAM, NSF/ANSI 61 (for Marprene tubing and loadsure elements), RoHS |
Drive ingress rating | IP31, IP66, NEMA 2, NEMA 4X |
Drive power supply | 115/230 V 1ph 50/60 Hz 135 VA |
Compatible tubing bore size | 0.5, 1.6, 3.2, 4.8, 6.4, 8, 9.6 mm |
WATSON MARLOW 300 SERIES CASED PUMP TECHMICAL SUMMERY:
Max. flow rate | 3000 ml/min |
Min. flow rate | 0.002 ml/min |
Speed control ratio | 133:1, 147:1, 200:1, 27:1, 300:1 |
Operating temperature range | 5 to 40 °C |
Operating temperature range | 40 to 104 °F |
Drive standards | CE, cETLus |
Drive ingress rating | IP31 |
Drive power supply | 1ph, 100-120 V, 220-240 V 50/60 Hz, 100 VA |
Compatible tubing bore size | 0.13, 0.19, 0.25, 0.38, 0.5, 0.63, 0.76, 0.8, 0.88, 1.02, 1.14, 1.29, 1.42, 1.52, 1.6, 1.65, 1.85, 2.05, 2.29, 2.54, 2.79, 3.2, 4.8, 6.4, 8 mm |
TECHNICAL SUMMERY OF WATSON MARLOW 100 SERIES CASED PUMP:
Max. flow rate | 190 ml/min |
Min. flow rate | 0.0001 ml/min |
Max. flow rate | 3.04 USGPH |
Min. flow rate | 0.00002 USGPH |
Max. operating pressure | 2 bar |
Max. operating pressure | 30 psi |
Speed control ratio | 100:1, 1000:1, 200:1, 2000:1, 32:1, 320:1 |
Operating temperature range | 5 to 40 °C |
Operating temperature range | 40 to 104 °F |
Standards | CE, cETLus |
Ingress rating | IP31, NEMA 2 |
Power supply | Supplied with 24 VDC mains transformer plug (range 90-264 VAC 47-63 Hz) which comes with multi-country adaptors |
TECHMICAL SUMMERY FOR WATSON MARLOW Quantum single-use bioprocessing pumps:
Min. flow rate | 5.33 ml/min |
Max. flow rate | 20 L/min |
Max. operating pressure | 3 bar |
Speed control ratio | 4000:1 |
Operating temperature range | 5 to 30 °C |
Operating temperature range | 41 to 86 °F |
Control types | Remote Analogue/Digital |
Standards | CE, cETLus, IEC 61010-1 |
Ingress rating | IP66, NEMA 12/13 |
Power supply | 100-120 V/200-240 V 1ph 50/60 Hz 250 VA |
Qdos Chemical Metering Pumps:
Delivering flow rates that remain constant right up to 7 bar Qdos chemical metering pumps give users a unique advantage over diaphragm metering pumps. Qdos pumps offer long maintenance intervals - reducing the impact of process downtime and lowering the overall cost of ownership.