Need help? Call us: 01326 708334, 01326 708335 or info@voltecbd.com
-
✅ Model: Siemens 7MH4960-4AA01
-
📦 Type: Load Cell Junction Box
-
🔧 Application: For industrial weighing systems
-
⚙️ Function: Summing signals from multiple load cells
-
🌐 Features: Reliable performance, easy installation, robust design
-
🏭 Ideal for: Batching systems, tank, hopper, and silo weighing
- RANGE:- 0.1-0.3m.
- OUTPUT:- NPN-LIGHT SWITCHING, NPN-DARK SWITCHING.
- SUPPLY VOLTAGE:-10-30VDC.
- Cable Type.
- Plastic HOUSING.
- RANGE: 0-0.4m
- OUTPUT: 1 - IO-Link / light switching (PNP)/dark switching (NPN) 2 - Dark switching (PNP)/light switching (NPN)
- SUPPLY VOLTAGE:-10-30VDC, 4-PIN.
- Connection: M8 CONNECTOR.
- HOUSING Material: Stainless steel
- RANGE: 0-2m
- OUTPUT: 1 – IO-Link / light switching (PNP)/dark switching (NPN) 2 – Dark switching (PNP)/light switching (NPN)
- SUPPLY VOLTAGE: 10-30VDC, 4-PIN.
- Connection: M8 CONNECTOR.
- HOUSING Material: Stainless steel
- RANGE: 0-0.4m
- OUTPUT: 1 - IO-Link / light switching (PNP)/dark switching (NPN) 2 - Dark switching (PNP)/light switching (NPN)
- SUPPLY VOLTAGE:-10-30VDC, 4-PIN.
- Connection: M8 CONNECTOR.
- HOUSING Material: Stainless steel
- RANGE:- 0-3m.
- OUTPUT:- NPN-LIGHT SWITCHING, NPN-DARK SWITCHING.
- SUPPLY VOLTAGE:-10-30VDC, 4-PIN.
- M8 CONNECTOR.
- PLASTIC HOUSING.
- RANGE:- 0-3m.
- OUTPUT:- PNP-LIGHT SWITCHING, PNP-DARK SWITCHING.
- SUPPLY VOLTAGE:-10-30VDC, 4-PIN.
- M8 CONNECTOR.
- METAL HOUSING.
- RANGE:- 0-6m.
- OUTPUT:- NPN-LIGHT SWITCHING, NPN-DARK SWITCHING.
- SUPPLY VOLTAGE:-10-30VDC, 4-PIN.
- M12 CONNECTOR.
- METAL HOUSING.
- Data Transfer: 100MBit/s
- Transistor, PNP
- Measurement range: 0...65,000 mm
- Detection angle: 190°
- Scanning rate: 25 scans/s
- Interface: Ethernet, RS 232, RS 422
- Transistor, PNP
- Measurement range: 0...65,000 mm
- Detection angle: 190°
- Scanning rate: 25 scans/s
- Interface: RS 232/422
- Transistor, PNP
- Measurement range: 0...65,000 mm
- Detection angle: 190°
- Scanning rate: 25 scans/s
- Interface: RS 232/422
- Dust suppression
- Measurement range: 0...25,000 mm
- Detection angle: 190°
- Scanning rate: 25 scans/s
- Interface: RS 232/422
- Data Transfer: 100MBit/s
- Interface: RS 232/422
- Measurement range: 0...25,000 mm
- Detection angle: 190°
- Scanning rate: 50 scans/s
- RANGE: 120-3000MM
- OUTPUT: PNP-LIGHT SWITCHING/DARK SWITCHING
- SUPPLY VOLTAGE: 10-30VDC
- CABLE TYPE, 2000MM
- 4 WIRE
- PLASTIC HOUSING
- Operating range: 0.7 … m
- Application: Detection of stretch-wrapped objects
- Light source: LED, Red
- Wavelength: 640 nm
- Switching element: PNP
- Switching principle: Light switching
- Operating range: 0 ... 2 m
- Beam path: Collimated
- Light source: Laser, Red
- Wavelength: 655 nm
- Switching element: PNP
- Switching principle: Light switching
- RANGE: 0-3m
- OUTPUT: PNP-LIGHT SWITCHING
- SUPPLY VOLTAGE: 10-30VDC
- M8 CONNECTOR
- PLASTIC HOUSING
- RANGE: 0-4m
- OUTPUT: PNP-LIGHT SWITCHING/DARK SWITCHING
- SUPPLY VOLTAGE: 10-30VDC
- M12 CONNECTOR
- PLASTIC HOUSING
- RANGE: 120-1200MM
- OUTPUT: PNP-LIGHT SWITCHING
- SUPPLY VOLTAGE: 10-30VDC
- M12 CONNECTOR
- PLASTIC HOUSING
- RANGE: 0.02-5m
- OUTPUT: PNP-LIGHT SWITCHING
- SUPPLY VOLTAGE: 10-30VDC
- CABLE TYPE
- 3 WIRE
- PLASTIC HOUSING
- RANGE: 0.02-5m
- OUTPUT: NPN-LIGHT SWITCHING
- SUPPLY VOLTAGE: 10-30VDC
- CABLE TYPE
- 3 WIRE
- PLASTIC HOUSING
- RANGE: 50-1000MM
- OUTPUT: PNP-LIGHT SWITCHING
- SUPPLY VOLTAGE: 10-30VDC
- CABLE TYPE
- 3 WIRE
- PLASTIC HOUSING
- RANGE: 15-400MM
- OUTPUT: NPN-LIGHT
- SWITCHING
- CABLE TYPE
- 3 WIRE
- PLASTIC HOUSING
- SUPPLY VOLTAGE: 10-30VDC
- RANGE: 0.05-8m
- OUTPUT: NPN-DARK SWITCHING
- SUPPLY VOLTAGE: 10-30VDC
- M12 CONNECTOR
- 4 PIN
- PLASTIC HOUSING
- Connection of additional universal alarm inputs
- Adding free inputs for display and supervision
- Event logging (e.g. legionella function)
- Additional time programs (ON / OFF) for basic functions
- Calculation of enthalpy, enthalpy differential, absolute humidity, dewpoint and wet bulb temperature
- Logic function blocks for switching on / off depending on different conditions
- Lead / lag control of pumps, fans, motors, etc., with automatic changeover
- Step switch with linear, binary or flexible functionality
- RANGE: 0-1m.
- OUTPUT: PNP-LIGHT. SWITCHING /DARK SWITCHING.
- SUPPLY VOLTAGE: 10-30VDC.
- CABLE TYPE.
- 4 WIRE.
- PLASTIC HOUSING.
- RANGE: 0.05-8m.
- OUTPUT: PNP-DARK SWITCHING.
- SUPPLY VOLTAGE: 10-30VDC.
- M12 CONNECTOR.
- 4 PIN.
- PLASTIC HOUSING.
- RANGE: 0.05-8m.
- OUTPUT: PNP-DARK SWITCHING.
- SUPPLY VOLTAGE: 10-30VDC.
- M12 CONNECTOR.
- 4 PIN.
- PLASTIC HOUSING.
- RANGE: 15-400MM.
- OUTPUT: PNP-LIGHT SWITCHING.
- SUPPLY VOLTAGE: 10-30VDC.
- CABLE TYPE .
- 3 WIRE.
- PLASTIC HOUSING.
- RANGE: 15-400MM.
- OUTPUT: NPN-LIGHT SWITCHING.
- SUPPLY VOLTAGE:-10-30VDC.
- CABLE TYPE.
- 3 WIRE.
- PLASTIC HOUSING.
- RANGE: 0-2.4m.
- SUPPLY VOLTAGE:-26.5-31.6 VDC.
- M12 CONNECTOR.
- 5-PIN.
- AS-INTERFACE IO.
- METAL HOUSING.
- Series :-318B.
- Operating principle:-Diffuse reflection principle.
- Application:-Detection of dark objects at short range.
- RANGE:- 0-4m.
- OUTPUT:- PNP-LIGHT SWITCHING, PNP-DARK SWITCHING.
- SUPPLY VOLTAGE:-10-30VDC, 4-PIN.
- M12 CONNECTOR.
- METAL HOUSING.
- RANGE: 20-100MM.
- OUTPUT: PNP-LIGHT SWITCHING.
- PNP-DARK SWITCHING.
- SUPPLY VOLTAGE:-10-30VDC.
- M8 CONNECTOR.
- PLASTIC HOUSING.
Series:-3C.
Operating principle:-Reflection principle.
Application:-
Read more
- Detection of highly transparent bottles.
- Detection of transparent films.
1766-L32AWA | MicroLogix 1400, 20 digital 120V ac inputs, 12 Relay outputs, 110/240V ac power | |
1766-L32AWAA | MicroLogix 1400, 20 digital 120V ac inputs, 12 Relay outputs, 4 Analog (12 bits) inputs, 2 Analog (12 bits) outputs, 110/240V ac power | |
1766-L32BWA | MicroLogix 1400, 12 digital fast 24V dc inputs, 8 digital normal 24V dc inputs, 12 relays outputs, 110/240V ac power | |
1766-L32BWAA | MicroLogix 1400, 12 digital fast 24V dc inputs, 8 digital normal 24V dc inputs, 12 relays outputs, 4 Analog (12 bits) inputs, 2 Analog (12 bits) outputs, 110/240V ac power | |
1766-L32BXB | MicroLogix 1400, 12 digital fast 24V dc inputs, 8 digital 24V dc inputs, 6 relay outputs, 3 fast 24V dc outputs, 3 normal 24V dc outputs, 24V dc power | |
1766-L32BXBA | MicroLogix 1400, 12 digital fast 24V dc inputs, 8 digital 24V dc inputs, 6 relay outputs, 3 fast 24V dc outputs, 3 normal 24V dc outputs, 4 Analog (12 bits) inputs, 2 Analog (12 bits) outputs, 24V dc power | |
1766-MM1 | Memory Module for MicroLogix 1400 |
- Reliable detection even with reflective objects.
- Operating ranges up to 24 m.
- Highly accurate positioning through extremely small laser light spot.
- Series: 5.
- Operating range, max.: 0.02 ... 4.5 m.
- Design: Cubic.
- Light source: LED, Red.
LOGO! 12/24RCE, a logic module with display, voltage supply: 12/24V DC/relay, 8DI (Digital Inputs), 4 of which can be used as AI (Analogue Inputs), 4DO (Digital Outputs), memory: 400 blocks, expandable, Ethernet, integral web server, data logging, standard micro SD card, for LOGO! SOFT COMFORT from version 8, older projects executable.
SIMATIC DP, Electronics module for ET 200S, 2 AO I 15 mm width, +/-20mA; 13 bit+sign, 4..20mA; 13 bit Cycle time less than 1 ms with SF LED (group fault).
Read more
Specifications
Attribute |
Value |
For Use With |
SIMATIC S7-200 Series |
Manufacturer Series |
S7-200 |
Number of Inputs |
14 |
Number of Digital Inputs |
14 |
Output Type |
Analogue, Digital, Transistor |
Voltage Category |
20.4 → 28.8 V dc |
Input Type |
Analogue, Digital |
Number of Digital Outputs |
10 |
Number of Outputs |
10 |
Communication Port Type |
RS485 |
Program Capacity |
12 kB |
Programming Language Used |
AWL, FUP, Ladder Logic |
Mounting Type |
Rack Mount |
Programming Interface |
Computer, SIMATIC PG/PC |
Output Current |
750 mA |
Number of Communication Ports |
1 |
Battery Backup |
Yes |
Length |
80mm |
Memory |
12 (Program Memory) kB, 8 (Data Memory) kB |
Width |
120.5mm |
Dimensions |
80 x 120.5 x 62 mm |
Maximum Operating Temperature |
+45°C |
Minimum Operating Temperature |
0°C |
Depth |
62mm |
SITOP DC UPS module 24 V/15 A uninterruptible power supply without interface input: 24 V DC/16 A output: 24 V DC/15 A.
Read more
- SIMATIC HMI TP900 Comfort.
- Comfort Panel.
- Touch operation.
- 9 "TFT display (widescreen).
- 16 million Colours.
- PROFINET interface.
- MPI/PROFIBUS-DP interface.
- Configuration memory: 12 MByte.
- Windows CE 6.0 (Microsoft-Support incl. Security updates discontinued) configurable from WinCC Comfort V11.
SIMATIC S7-200, CPU 226 Compact unit, AC power supply 24 DI DC/16 DO relay 16/24 KB program./10 KB data, 2 PPI/user-programmable interface.
SIMATIC S7-200, CPU 224XP Compact unit, DC power supply 14 DI DC/10 DO DC, 2 AI, 1 AO, 12/16 KB progr./10 KB data, 2 PPI/user-programmable interface.
Read more

Voltec Engineering Limited
Automation and control products are the focus of VOLTEC ENGINEERING LIMITED. In the area of comprehensive industry solutions for alteration, upgrading, and new construction projects, VOLTEC ENGINEERING LIMITED is a one-stop solution provider.
Need Help?
01326 708335
01329 727092
Customer Service
© 2023 Voltec Engineering Ltd. | Design & Developed by mPair Technologies Ltd.