Need help? Call us: 01326 708334, 01326 708335 or info@voltecbd.com
- input specification type 1/3
- no bouncing due to mechanical switches thanks to 3 ms input filter
- tool-free connection by direct plug-in technology for solid wire conductors
- space-saving use in the control cabinet
- direct connection of multi-channel sensors in 1-wire connection technology in the smallest space
- increased packing density with 16 connection points in the housing of a 12 mm terminal bloc
Offering a range of encoder from basic to the programmable. Datalogic encoders offer dimension reduction, without compromising robustness and overall performance.
ENC41-H06-0100-C15, ENC41-H06-0360-C15, ENC41-H06-0500-C15,ENC41-H06-1000-C15, ENC41-H06-1024-C15,ENC41-H06-2048-C15, ENC41-H06-4096-C15, ENC41-S06-0100-C15, ENC41-S06-0360-C15, ENC41-S06-0500-C15,ENC41-S06-1000-C15, ENC41-S06-1024-C15, ENC41-S06-2048-C15, ENC41-S06-4096-C15, FAC06-06,FBC06-06
Read more
For labeling and packaging, 953151070 SR21-IR 2 MM HIGH-RESOLUTION FORK SENSORS
1. A high switching frequency of 25 kHz
2. Models with IR or red/green lights
3. Label detection (SR21-IR) or print register mark detection (SR21-RG) on transparent films
4. 4 wire output with NPN and PNP
Read more
♦ A wide range of optic connections and functions.
♦ For all functions, long operating distances.
♦ Models with stable LEDs and trimmer adjustments.
♦ Plastic housing that is durable and impermeable.
Read more
Technical Summary:
Max. flow rate | 3300 L/h |
Min. flow rate | 0.12 L/h |
Max. flow rate | 872 USGPH |
Min. flow rate | 0.03 USGPH |
Drive speed control ratio | 3600:1 |
Operating temperature range | 5 to 40 °C |
Operating temperature range | 40 to 104 °F |
Control types | EtherNet/IP™, Profibus®, Profinet®, Remote Analogue/Digital, RS485, SCADA |
Drive standards | CE, cETLus, C-Tick, IRAM, NSF/ANSI 61 (for Marprene tubing and loadsure elements) |
Drive ingress rating | IP66, NEMA 4X |
Drive power supply | 100-120 V/200-240 V 1ph 50/60 Hz 350 VA |
Compatible tubing bore size | 9.6, 12.7, 15.9, 19, 25.4 mm |
Technical Summary
Max. flow rate | 18 L/min |
Min. flow rate | 0.001 L/min |
Max. flow rate | 301 USGPH |
Min. flow rate | 0.02 USGPH |
Drive speed control ratio | 2650:1 |
Operating temperature range | 5 to 40 °C |
Operating temperature range | 41 to 104 °F |
Control types | EtherNet/IP™, Profibus®, Profinet®, Remote Analogue/Digital, RS232, RS485, SCADA |
Drive standards | CE, cETLus, C-Tick, IRAM, NSF/ANSI 61 (for Marprene tubing and loadsure elements) |
Drive ingress rating | IP31, IP66, NEMA 2, NEMA 4X |
Drive power supply | 100-120 V/200-240 V 1ph 50/60 Hz 250 VA |
Compatible tubing bore size |
Technical Summary:
Max. flow rate | 3500 ml/min |
Min. flow rate | 0.004 ml/min |
Max. flow rate | 56 USGPH |
Min. flow rate | 0 USGPH |
Drive speed control ratio | 2200:1 |
Operating temperature range | 5 to 40 °C |
Operating temperature range | 40 to 104 °F |
Control types | EtherNet/IP™, Profibus®, Profinet®, Remote Analogue/Digital, RS232, RS485, SCADA |
Drive standards | CE, cETLus, C-Tick, IRAM, NSF/ANSI 61 (for Marprene tubing and loadsure elements), RoHS |
Drive ingress rating | IP31, IP66, NEMA 2, NEMA 4X |
Drive power supply | 115/230 V 1ph 50/60 Hz 135 VA |
Compatible tubing bore size | 0.5, 1.6, 3.2, 4.8, 6.4, 8, 9.6 mm |
WATSON MARLOW 300 SERIES CASED PUMP TECHMICAL SUMMERY:
Max. flow rate | 3000 ml/min |
Min. flow rate | 0.002 ml/min |
Speed control ratio | 133:1, 147:1, 200:1, 27:1, 300:1 |
Operating temperature range | 5 to 40 °C |
Operating temperature range | 40 to 104 °F |
Drive standards | CE, cETLus |
Drive ingress rating | IP31 |
Drive power supply | 1ph, 100-120 V, 220-240 V 50/60 Hz, 100 VA |
Compatible tubing bore size | 0.13, 0.19, 0.25, 0.38, 0.5, 0.63, 0.76, 0.8, 0.88, 1.02, 1.14, 1.29, 1.42, 1.52, 1.6, 1.65, 1.85, 2.05, 2.29, 2.54, 2.79, 3.2, 4.8, 6.4, 8 mm |
TECHNICAL SUMMERY OF WATSON MARLOW 100 SERIES CASED PUMP:
Max. flow rate | 190 ml/min |
Min. flow rate | 0.0001 ml/min |
Max. flow rate | 3.04 USGPH |
Min. flow rate | 0.00002 USGPH |
Max. operating pressure | 2 bar |
Max. operating pressure | 30 psi |
Speed control ratio | 100:1, 1000:1, 200:1, 2000:1, 32:1, 320:1 |
Operating temperature range | 5 to 40 °C |
Operating temperature range | 40 to 104 °F |
Standards | CE, cETLus |
Ingress rating | IP31, NEMA 2 |
Power supply | Supplied with 24 VDC mains transformer plug (range 90-264 VAC 47-63 Hz) which comes with multi-country adaptors |
TECHMICAL SUMMERY FOR WATSON MARLOW Quantum single-use bioprocessing pumps:
Min. flow rate | 5.33 ml/min |
Max. flow rate | 20 L/min |
Max. operating pressure | 3 bar |
Speed control ratio | 4000:1 |
Operating temperature range | 5 to 30 °C |
Operating temperature range | 41 to 86 °F |
Control types | Remote Analogue/Digital |
Standards | CE, cETLus, IEC 61010-1 |
Ingress rating | IP66, NEMA 12/13 |
Power supply | 100-120 V/200-240 V 1ph 50/60 Hz 250 VA |
Qdos Chemical Metering Pumps:
Delivering flow rates that remain constant right up to 7 bar Qdos chemical metering pumps give users a unique advantage over diaphragm metering pumps. Qdos pumps offer long maintenance intervals - reducing the impact of process downtime and lowering the overall cost of ownership. Eaton Bussmann series 15149 fused pullout switch, 600V, 0-30A, 200 kAIC, Fusible, Dead Front, Three-pole.
Read more
Core features
- Available in NEMA 1, 3R, 4, 4X, 12 enclosures for a broad range of application environments.
- Most common disconnect switches in stock and ship within 24 hours with QuikShip Everyday Service to meet project requirements.
- Multiple field-installed accessories enhance the enclosed disconnect switches to fit the desired application.
- UL 508 Listed for motor disconnect applications.
- 3- and 6-Pole UL 508 motor disconnect switches provide flexibility for single or dual motor applications.
- NEMA 4X 30A and 60A motor control disconnects.
Eaton Bussmann series CCP compact circuit protector, Compact Circuit Protector, 30 A, Single-pole, 20 lb-in, Class G, Screw with pressure plate, Front panel, 240 V.
Read more
The EK1100 EtherCAT Coupler is the link between the EtherCAT protocol at the fieldbus level and the EtherCAT Terminals. The coupler converts the passing telegrams from Ethernet 100BASE-TX to E-bus signal representation. A station consists of a coupler and any number of EtherCAT Terminals that are automatically detected and individually displayed in the process image.
Read more

Voltec Engineering Limited
Automation and control products are the focus of VOLTEC ENGINEERING LIMITED. In the area of comprehensive industry solutions for alteration, upgrading, and new construction projects, VOLTEC ENGINEERING LIMITED is a one-stop solution provider.
Need Help?
01326 708335
01329 727092
Customer Service
© 2023 Voltec Engineering Ltd. | Design & Developed by mPair Technologies Ltd.