Need help? Call us: 01326 708334, 01326 708335 or info@voltecbd.com
- Functional principle: Diffuse reflective
- Sensing range: 1 to 30 mm
- Connection type: M8 4-pin plug
- Output Type: NPN
- Operation mode: Light ON
For Price Call: 01329727092
Email: sales@voltecbd.com
- Functional principle: Through-beam
- Sensing range: 500 mm
- Connection type: M8 4-pin plug
- Output Type: PNP
- Operation mode: Light ON
For Price Call: 01329727092
Email: sales@voltecbd.com
- Sensing range (max.): 25 mm
- Connection type: M12 connector
- Switching frequency: 100 Hz
- Installation type: Non Flush
For Price Call: 01329727092
Email: sales@voltecbd.com
- Operation distance_OFF→ON: ± 10 mm
- Operation distance_ON→OFF: ± 20 mm
- Output function: NO
- Operating frequency: 500 Hz
- Switching voltage: ≤ 24VDC
For Price Call: 01329727092
Email: sales@voltecbd.com
- Sensing range (max.): 12 mm
- Connection type: Cable type
- Switching frequency: 50 Hz
- Installation type: Flush
For Price Call: 01329727092
Email: sales@voltecbd.com
- Sensing range (max.): 8 mm
- Switching Output: PNP
- Output function: NO
- Switching frequency: 50 Hz
For Price Call: 01329727092
Email: sales@voltecbd.com
- Sensing range (max.): 15 mm
- Connection type: M12 Connector cable
- Output function: NC
- Switching frequency: 20 Hz
- Installation type: Non Flush
For Price Call: 01329727092
Email: sales@voltecbd.com
- Sensing range (max.): 12 mm
- Connection type: M12 plug connector
- Switching output: PNP
- Output function: NO
- Switching frequency: 10 Hz
- Installation type: Flush
For Price Call: 01329727092
Email: sales@voltecbd.com
- Applicable fluid : (Pneumatic type) Air, Non-corrosive gas
- Pressure port direction : Rear fitting
- Pressure port : Rc1/8
- Connection type : Connector type(connector type cable: 2m)
- Pressure type : Standard pressure
- Power voltage : 12-24VDC
±10%(ripple P-P: max. 10%)
- Current consumption : Voltage output type: Max. 50mA Current output type: Max. 75mA
- Protection structure : IP40
For Price Call: 01329727092
Email: sales@voltecbd.com
- Sensing type : Through-beam type
- Sensing distance : 30m
- Sensing target : Opaque material of min. Ø15mm
- Light source : Red LED(660nm)
- Response time : Max. 1ms
- Measured materials : Liquid, gas, oil
- Measurement pressure : Gauge pressure
- Pressure range : 0 to 10kgf/cm²
TECHNICAL SUMMERY OF WATSON MARLOW 100 SERIES CASED PUMP:
| Max. flow rate | 190 ml/min |
| Min. flow rate | 0.0001 ml/min |
| Max. flow rate | 3.04 USGPH |
| Min. flow rate | 0.00002 USGPH |
| Max. operating pressure | 2 bar |
| Max. operating pressure | 30 psi |
| Speed control ratio | 100:1, 1000:1, 200:1, 2000:1, 32:1, 320:1 |
| Operating temperature range | 5 to 40 °C |
| Operating temperature range | 40 to 104 °F |
| Standards | CE, cETLus |
| Ingress rating | IP31, NEMA 2 |
| Power supply | Supplied with 24 VDC mains transformer plug (range 90-264 VAC 47-63 Hz) which comes with multi-country adaptors |
KOBOLD room thermostats are suitable for industrial plants, greenhouses, and warehouses, and also for monitoring the maximum temperature in switchgear cabinets and relay stations. Room thermostats are supplied with TER-H 1 wall brackets.
Switching range:- -20 ... +20 ... +80 ... +130°C, adjustable. Material:-aluminum (housing). copper, brass, or stainless steel (probe). Micro switch:- SPDT max. 250 VAC, 8 (5) A at 250 VAC, 8 A at 24 VDC.TCN4S-24R
- Display method : 4-digit 7-segment LED
- Control method : ON/OFF, P, PI, PD, PID
- Input specification : Thermocouple: K(CA), J(IC), T(CC), R(PR), S(PR), L(IC) RTD: DPt100Ω, Cu50Ω
- Sampling cycle : 100ms
- Control output : Relay(250VAC~ 3A) or SSR drive(12VDC ) [ON/OFF]
- Power supply : 100-240VAC~ 50/60Hz
- Display method : 4-digit 7-segment LED.
- Control method : ON/OFF, P, PI, PD, PID.
- Input specification : Thermocouple: K(CA), J(IC), E(CR), T(CC), B(PR), R(PR), S(PR), N(NN), C(TT), G(TT), L(IC), U(CC), Platinel II. RTD: DPt100Ω, DPt50Ω, JPt100Ω, Cu100Ω, Cu50Ω, Nikel 120Ω. Analog: 0-100mV, 0-5V, 1-5V, 0-10V. 0-20mA, 4-20mA.
- Sampling cycle : 50ms.
- Control output 1 : Current(DC0/4-20mA) or SSR drive(11VDC
) [ON/OFF].
- Option output : Alarm 1, RS485 comm.
- Power supply : 100-240VAC~ 50/60Hz.
- Protection structure : IP65(front panel).
- Display method: 4-digit 7-segment LED.
- Control method: ON/OFF control, P, PI, PD, PIDF, PIDS control.
- Input specification : Thermocouple: K(CA), J(IC), E(CR), T(CC), R(PR), S(PR), N(NN), W(TT) RTD: DPt100Ω, JPt100Ω
- Analog: 1-5VDC , 0-10VDC , DC4-20mA..
- Sampling cycle: 500ms.
- Control output : Relay(250VAC~ 3A).
- Power supply : 100-240VAC~ 50/60Hz.
Temp Control, 1/4 DIN, Zone PID, RS485, 100-240VAC; Fixed Control, 4 Alarm, Current/SSR Drive Out1&2, 1 CT+3 Digital Input,
Read more
Voltec Engineering Limited
Automation and control products are the focus of VOLTEC ENGINEERING LIMITED. In the area of comprehensive industry solutions for alteration, upgrading, and new construction projects, VOLTEC ENGINEERING LIMITED is a one-stop solution provider.
© 2025 Voltec Engineering Ltd. | Design & Developed by mPair Technologies Ltd.