Need help? Call us: 01326 708334, 01326 708335 or info@voltecbd.com
- Sensing range (max.): 60 mm
- Connection type: Cable PUR, 2 m
- Switching output: PNP
- Output function: NC
- Switching frequency: 5 kHz
- Installation type: Flush
For Price Call: 01329727092
Email: sales@voltecbd.com
- Sensing range (max.): 60 mm
- Connection type: Cable PUR, 2 m
- Switching output: NPN
- Output function: NC
- Switching frequency: 5 kHz
- Installation type: Flush
For Price Call: 01329727092
Email: sales@voltecbd.com
- Sensing range (max.): 60 mm
- Connection type: Cable PUR, 2 m
- Switching output: PNP
- Output function: NO
- Switching frequency: 5 kHz
- Installation type: Flush
For Price Call: 01329727092
Email: sales@voltecbd.com
- Sensing range (max.): 2 mm
- Connection type: Cable, L=2 m
- Switching output: PNP
- Output function: NC
- Switching frequency: 3 kHz
- Installation type: Flush
For Price Call: 01329727092
Email: sales@voltecbd.com
- Sensing range (max.): 0.8 mm
- Connection type: Cable, L=2 m
- Switching output: NPN
- Output function: NC
- Switching frequency: 3 kHz
- Installation type: Flush
For Price Call: 01329727092
Email: sales@voltecbd.com
- Sensing range (max.): 4 mm
- Connection type: Cable PVC 3 x 0,14, 2 m
- Output function: NO
- Switching frequency: 35 Hz
- Installation type: Flush
For Price Call: 01329727092
Email: sales@voltecbd.com
- Sensing range (max.): 8 mm
- Connection type: Cable, L=2 m
- Switching output: NPN
- Output function: NC
- Switching frequency: 50 Hz
- Installation type: Flush
For Price Call: 01329727092
Email: sales@voltecbd.com
- Connection type: Connector AMPSEAL 16 3 pin
- Output Type: Voltage output
- Installation type: Non Flush
For Price Call: 01329727092
Email: sales@voltecbd.com
- Sensing range (max.): 0.1 mm
- Connection type: Flylead connector M8, L=200 mm
- Switching output: NPN
- Output function: NO
- Switching frequency: 15 Hz
- Installation type: Non Flush
For Price Call: 01329727092
Email: sales@voltecbd.com
- Sensing range (max.): 8 mm
- Connection type: Connector M8, 3 pin
- Switching output: NPN
- Output function: NC
- Switching frequency: 500 Hz
- Installation type: Flush
For Price Call: 01329727092
Email: sales@voltecbd.com
- Through beam sensor
- 120 mm
- Pulsed red LED
- PNP
- Potentiometer, 270°
- Ponnector M8, 3 pin
- -10 … 60 °C
- IP 67
- PNP/NPN
- Light / Dark Operate
- RGB LED
- Intiuitive teach-in
- 20 ms delay activatable
- Optional lenses for distances up to 22 mm
With retro-reflective sensors, the transmitter and receiver are located in one housing and combined with a prismatic reflector. The reflector reflects the emitted light beam and if the light is interrupted by an object, the sensor switches.
Read more
|
Individual relays |
|||
Individual relays within the RIDERSERIES RCM
|
|||
- The incremental HeavyDuty standard : HOG86 / POG86
- Unmatched variety, proven robustness : HOG9 / POG9
- The unrivalled benchmark : HOG10 / POG10
- The intelligent solution : HMG10P / PMG10P incremental
- SinCos output – LowHarmonics for outstanding signal quality: OGS71 ... HOGS151
- Solid shaft with EURO flange B10
- Complete portfolio of solid shaft designs
Technical Summary:
| Max. flow rate | 3300 L/h |
| Min. flow rate | 0.12 L/h |
| Max. flow rate | 872 USGPH |
| Min. flow rate | 0.03 USGPH |
| Drive speed control ratio | 3600:1 |
| Operating temperature range | 5 to 40 °C |
| Operating temperature range | 40 to 104 °F |
| Control types | EtherNet/IP™, Profibus®, Profinet®, Remote Analogue/Digital, RS485, SCADA |
| Drive standards | CE, cETLus, C-Tick, IRAM, NSF/ANSI 61 (for Marprene tubing and loadsure elements) |
| Drive ingress rating | IP66, NEMA 4X |
| Drive power supply | 100-120 V/200-240 V 1ph 50/60 Hz 350 VA |
| Compatible tubing bore size | 9.6, 12.7, 15.9, 19, 25.4 mm |
Technical Summary
| Max. flow rate | 18 L/min |
| Min. flow rate | 0.001 L/min |
| Max. flow rate | 301 USGPH |
| Min. flow rate | 0.02 USGPH |
| Drive speed control ratio | 2650:1 |
| Operating temperature range | 5 to 40 °C |
| Operating temperature range | 41 to 104 °F |
| Control types | EtherNet/IP™, Profibus®, Profinet®, Remote Analogue/Digital, RS232, RS485, SCADA |
| Drive standards | CE, cETLus, C-Tick, IRAM, NSF/ANSI 61 (for Marprene tubing and loadsure elements) |
| Drive ingress rating | IP31, IP66, NEMA 2, NEMA 4X |
| Drive power supply | 100-120 V/200-240 V 1ph 50/60 Hz 250 VA |
| Compatible tubing bore size |
Technical Summary:
| Max. flow rate | 3500 ml/min |
| Min. flow rate | 0.004 ml/min |
| Max. flow rate | 56 USGPH |
| Min. flow rate | 0 USGPH |
| Drive speed control ratio | 2200:1 |
| Operating temperature range | 5 to 40 °C |
| Operating temperature range | 40 to 104 °F |
| Control types | EtherNet/IP™, Profibus®, Profinet®, Remote Analogue/Digital, RS232, RS485, SCADA |
| Drive standards | CE, cETLus, C-Tick, IRAM, NSF/ANSI 61 (for Marprene tubing and loadsure elements), RoHS |
| Drive ingress rating | IP31, IP66, NEMA 2, NEMA 4X |
| Drive power supply | 115/230 V 1ph 50/60 Hz 135 VA |
| Compatible tubing bore size | 0.5, 1.6, 3.2, 4.8, 6.4, 8, 9.6 mm |
WATSON MARLOW 300 SERIES CASED PUMP TECHMICAL SUMMERY:
| Max. flow rate | 3000 ml/min |
| Min. flow rate | 0.002 ml/min |
| Speed control ratio | 133:1, 147:1, 200:1, 27:1, 300:1 |
| Operating temperature range | 5 to 40 °C |
| Operating temperature range | 40 to 104 °F |
| Drive standards | CE, cETLus |
| Drive ingress rating | IP31 |
| Drive power supply | 1ph, 100-120 V, 220-240 V 50/60 Hz, 100 VA |
| Compatible tubing bore size | 0.13, 0.19, 0.25, 0.38, 0.5, 0.63, 0.76, 0.8, 0.88, 1.02, 1.14, 1.29, 1.42, 1.52, 1.6, 1.65, 1.85, 2.05, 2.29, 2.54, 2.79, 3.2, 4.8, 6.4, 8 mm |
TECHNICAL SUMMERY OF WATSON MARLOW 100 SERIES CASED PUMP:
| Max. flow rate | 190 ml/min |
| Min. flow rate | 0.0001 ml/min |
| Max. flow rate | 3.04 USGPH |
| Min. flow rate | 0.00002 USGPH |
| Max. operating pressure | 2 bar |
| Max. operating pressure | 30 psi |
| Speed control ratio | 100:1, 1000:1, 200:1, 2000:1, 32:1, 320:1 |
| Operating temperature range | 5 to 40 °C |
| Operating temperature range | 40 to 104 °F |
| Standards | CE, cETLus |
| Ingress rating | IP31, NEMA 2 |
| Power supply | Supplied with 24 VDC mains transformer plug (range 90-264 VAC 47-63 Hz) which comes with multi-country adaptors |
TECHMICAL SUMMERY FOR WATSON MARLOW Quantum single-use bioprocessing pumps:
| Min. flow rate | 5.33 ml/min |
| Max. flow rate | 20 L/min |
| Max. operating pressure | 3 bar |
| Speed control ratio | 4000:1 |
| Operating temperature range | 5 to 30 °C |
| Operating temperature range | 41 to 86 °F |
| Control types | Remote Analogue/Digital |
| Standards | CE, cETLus, IEC 61010-1 |
| Ingress rating | IP66, NEMA 12/13 |
| Power supply | 100-120 V/200-240 V 1ph 50/60 Hz 250 VA |
Qdos Chemical Metering Pumps:
Delivering flow rates that remain constant right up to 7 bar Qdos chemical metering pumps give users a unique advantage over diaphragm metering pumps. Qdos pumps offer long maintenance intervals - reducing the impact of process downtime and lowering the overall cost of ownership. Features-
♦ Impulse counter.
♦ Adding.
♦ Display 6- or 8-digits.
♦ With or without a reset button.
♦ Socket housing.
Read more
Voltec Engineering Limited
Automation and control products are the focus of VOLTEC ENGINEERING LIMITED. In the area of comprehensive industry solutions for alteration, upgrading, and new construction projects, VOLTEC ENGINEERING LIMITED is a one-stop solution provider.
© 2025 Voltec Engineering Ltd. | Design & Developed by mPair Technologies Ltd.