Need help? Call us: 01326 708334, 01326 708335 or info@voltecbd.com
Main Applications
A1000 is designed to handle a wide range of applications, including:
-Hoists, cranes, etc.
-Extruders, mold injectors
-Presses and other machine tooling
-Mixers, separators, grinders, other rotational applications
-Conveyors and other material transport
-Compressors
-Fan, supply pumps, hydraulic pumps, etc.
Read more
- Series: DVP-SA Series PLC
- 10K Words Data Memory
- 24 Volts Power Supply
- 256 Max Input/Output
- 16k Steps Program Capacity
Technical Summary:
Max. flow rate | 3300 L/h |
Min. flow rate | 0.12 L/h |
Max. flow rate | 872 USGPH |
Min. flow rate | 0.03 USGPH |
Drive speed control ratio | 3600:1 |
Operating temperature range | 5 to 40 °C |
Operating temperature range | 40 to 104 °F |
Control types | EtherNet/IP™, Profibus®, Profinet®, Remote Analogue/Digital, RS485, SCADA |
Drive standards | CE, cETLus, C-Tick, IRAM, NSF/ANSI 61 (for Marprene tubing and loadsure elements) |
Drive ingress rating | IP66, NEMA 4X |
Drive power supply | 100-120 V/200-240 V 1ph 50/60 Hz 350 VA |
Compatible tubing bore size | 9.6, 12.7, 15.9, 19, 25.4 mm |
Technical Summary
Max. flow rate | 18 L/min |
Min. flow rate | 0.001 L/min |
Max. flow rate | 301 USGPH |
Min. flow rate | 0.02 USGPH |
Drive speed control ratio | 2650:1 |
Operating temperature range | 5 to 40 °C |
Operating temperature range | 41 to 104 °F |
Control types | EtherNet/IP™, Profibus®, Profinet®, Remote Analogue/Digital, RS232, RS485, SCADA |
Drive standards | CE, cETLus, C-Tick, IRAM, NSF/ANSI 61 (for Marprene tubing and loadsure elements) |
Drive ingress rating | IP31, IP66, NEMA 2, NEMA 4X |
Drive power supply | 100-120 V/200-240 V 1ph 50/60 Hz 250 VA |
Compatible tubing bore size |
Technical Summary:
Max. flow rate | 3500 ml/min |
Min. flow rate | 0.004 ml/min |
Max. flow rate | 56 USGPH |
Min. flow rate | 0 USGPH |
Drive speed control ratio | 2200:1 |
Operating temperature range | 5 to 40 °C |
Operating temperature range | 40 to 104 °F |
Control types | EtherNet/IP™, Profibus®, Profinet®, Remote Analogue/Digital, RS232, RS485, SCADA |
Drive standards | CE, cETLus, C-Tick, IRAM, NSF/ANSI 61 (for Marprene tubing and loadsure elements), RoHS |
Drive ingress rating | IP31, IP66, NEMA 2, NEMA 4X |
Drive power supply | 115/230 V 1ph 50/60 Hz 135 VA |
Compatible tubing bore size | 0.5, 1.6, 3.2, 4.8, 6.4, 8, 9.6 mm |
WATSON MARLOW 300 SERIES CASED PUMP TECHMICAL SUMMERY:
Max. flow rate | 3000 ml/min |
Min. flow rate | 0.002 ml/min |
Speed control ratio | 133:1, 147:1, 200:1, 27:1, 300:1 |
Operating temperature range | 5 to 40 °C |
Operating temperature range | 40 to 104 °F |
Drive standards | CE, cETLus |
Drive ingress rating | IP31 |
Drive power supply | 1ph, 100-120 V, 220-240 V 50/60 Hz, 100 VA |
Compatible tubing bore size | 0.13, 0.19, 0.25, 0.38, 0.5, 0.63, 0.76, 0.8, 0.88, 1.02, 1.14, 1.29, 1.42, 1.52, 1.6, 1.65, 1.85, 2.05, 2.29, 2.54, 2.79, 3.2, 4.8, 6.4, 8 mm |
TECHNICAL SUMMERY OF WATSON MARLOW 100 SERIES CASED PUMP:
Max. flow rate | 190 ml/min |
Min. flow rate | 0.0001 ml/min |
Max. flow rate | 3.04 USGPH |
Min. flow rate | 0.00002 USGPH |
Max. operating pressure | 2 bar |
Max. operating pressure | 30 psi |
Speed control ratio | 100:1, 1000:1, 200:1, 2000:1, 32:1, 320:1 |
Operating temperature range | 5 to 40 °C |
Operating temperature range | 40 to 104 °F |
Standards | CE, cETLus |
Ingress rating | IP31, NEMA 2 |
Power supply | Supplied with 24 VDC mains transformer plug (range 90-264 VAC 47-63 Hz) which comes with multi-country adaptors |
TECHMICAL SUMMERY FOR WATSON MARLOW Quantum single-use bioprocessing pumps:
Min. flow rate | 5.33 ml/min |
Max. flow rate | 20 L/min |
Max. operating pressure | 3 bar |
Speed control ratio | 4000:1 |
Operating temperature range | 5 to 30 °C |
Operating temperature range | 41 to 86 °F |
Control types | Remote Analogue/Digital |
Standards | CE, cETLus, IEC 61010-1 |
Ingress rating | IP66, NEMA 12/13 |
Power supply | 100-120 V/200-240 V 1ph 50/60 Hz 250 VA |
Qdos Chemical Metering Pumps:
Delivering flow rates that remain constant right up to 7 bar Qdos chemical metering pumps give users a unique advantage over diaphragm metering pumps. Qdos pumps offer long maintenance intervals - reducing the impact of process downtime and lowering the overall cost of ownership. MODEL :-GA70C4002BBA.
Read more
The new adaptable Yaskawa AC drive for industrial applications is the GA700. Its adaptability, compact size, and built-in features enable a seamless integration into almost any application. Clever features that help during setup and troubleshooting to save time include the Startup Wizard, data recording, the DriveWizard Mobile app, and many others.
With over 1,000,000 installed and working elevator drives, Yaskawa has demonstrated its success in producing and providing drives to the elevator business. A dedicated drive for elevator applications, the L1000A Drive Series is appropriate for both new installations and renovation work.
Compact V/f Control Drive
Models:-
200 V Class, Three-Phase Input: 0.1 to 5.5 kW.
200 V Class, Single-Phase Input: 0.1 to 2.2 kW.
400 V Class, Three-Phase Input: 0.2 to 5.5 kW.
Read more
Compact Vector Control Drive
Models:-
200 V Class, Three-Phase Input: 0.1 to 18.5 kW
200 V Class, Single-Phase Input: 0.1 to 3.7 kW
400 V Class, Three-Phase Input: 0.2 to 18.5 kW
Read more
Models:-
200 V Class: 0.4 to 110 kW (3/4 to 175 HP ND)
400 V Class: 0.4 to 630 kW (3/4 to 1000 HP ND)
600 V Class: 0.75 to 185 kW (1 to 250 HP ND)
Read more

Voltec Engineering Limited
Automation and control products are the focus of VOLTEC ENGINEERING LIMITED. In the area of comprehensive industry solutions for alteration, upgrading, and new construction projects, VOLTEC ENGINEERING LIMITED is a one-stop solution provider.
Need Help?
01326 708335
01329 727092
Customer Service