Features-

  • According to wenglor weproTec, there is very little mounting clearance.
  • ASIC circuit technology that is innovative.
  • Built-in error display.

Description

WENGLOR Inductive Sensor with Standard Switching Distances I12N001

WENGLOR Inductive Sensor

Increased switching distance inductive sensors are differentiated by their robust design, simple installation, and accurate measured values. Other sensor types are unnecessary due to the wide range because they can also be employed to implement specialized applications. The new generation offers the capability of identifying system issues before it’s too late owing to ASIC and wenglor weproTec, in addition to error-free operation of several sensors in a very small space.

Inductive Data

Switching Distance 2 mm
Correction Factors Stainless Steel V2A/CuZn/Al 1,13/0,64/0,57
Mounting Flush
Mounting A/B/C/D in mm 0/8/6/0
Mounting B1 in mm 0…1
Switching Hysteresis < 10 %

WENGLOR Inductive Sensor

Electrical Data

Supply Voltage 10 … 30 V DC
Current Consumption (Ub = 24 V) < 6 mA
Switching Frequency 1,180 Hz
Temperature Drift < 10 %
Temperature Range -40 … 80 °C
Switching Output Voltage Drop < 1 V
Switching Output/Switching Current 150 mA
Residual Current Switching Output < 100 µA
Short Circuit Protection yes
Reverse Polarity and Overload Protection yes
Protection Class III

WENGLOR Inductive Sensor

Mechanical Data

Housing Material CuZn, nickel-plated
Degree of Protection IP67
Connection M12 × 1; 3-pin

Safety-relevant Data

MTTFd (EN ISO 13849-1) 3,706.54 a

Function

Error Indicator yes

Output

PNP NO yes