EUROTHERM 2704 Advanced Multi-loop Temperature Controllers

Add to Wishlist
Add to Wishlist

The 2704 is a single, two, or triple-loop format process controller that is extremely accurate and stable. Setpoint programming and a wide range of arithmetic and logic functions are included.

Description

EUROTHERM 2704 Advanced Multi-loop Temperature Controllers

EUROTHERM Temperature Controllers

Humidity control supplement

The 2704 is ideal for use in applications where it is necessary to simulate the environmental conditions of temperature, humidity and sometimes altitude. Control of these conditions requires certain unique features from a controller. Firstly, the controller needs to be able to generate a setpoint profile. This feature allows the user to predefine a series of setpoint changes. Secondly, the controller needs to be able to measure humidity using either the traditional Wet/Dry bulb method or by interfacing with solid-state sensors. The controller may also be required to turn a refrigeration compressor on and off, operate a bypass valve, and possibly operate two stages of heating and/or cooling.

Ideal for:-

Reliability testing.

Climatic simulation.

Culture & plant growth.

Simulated altitude control. 

Features:-

  • Synchronised setpoint profiles.
  • %RH & dewpoint measurement.
  • Altitude compensation.
  • Compressor timer.

    EUROTHERM 2704 Advanced Multi-loop Temperature Controllers

Temperature control-

The temperature of the environmental chamber is controlled via a single loop with two control outputs. The heating output time proportions electric heaters, usually via a solid state relay. The cooling output normally operates a refrigerant valve which introduces cooling agents into the chamber. The 2704 has an advanced PID control algorithm which automatically calculates when heating or cooling is required. Additional stages of both heating and cooling can also be implemented if required.

Altitude control-

Altitude is simulated by controlling the pressure inside the chamber. Usually, a vacuum is drawn to simulate high altitudes. If the application requires simulating altitude at sea level and the chamber is located at an altitude higher than sea level, then the chamber must also be pressurised. Again, a two-channel output controller is required. Pressure varies nonlinearly with altitude so the pressure signal must have a special linearisation applied to it.

Humidity control-

Humidity in a chamber is controlled by adding or removing Water vapour. As with the temperature control loop, two control outputs are required(i.e.Humidify and Dehumidify). The humidity output regulates the amount of steam allowed into the chamber, adding steam increases the humidity level. Water vapour is added by either a boiler, evaporating pan or by direct injection of atomised water.

· Evaporating pan of water warmed by a heater regulates the humidity level by controlling the temperature of the water.

· Atomisation system uses compressed air to spray water vapour directly into the chamber. The same compressor used for cooling the chamber accomplishes dehumidification. Different sets of ‘heat’ exchanger coils are used along with a different control valve.

Compressor control-

Another requirement of the controller is to be able to start and stop the cooling compressor. To alleviate wear and tear caused by cycling the compressor, the chamber controller will turn the compressor on and leave it on whenever cooling or dehumidification is required. The compressor will usually be kept running for 5 to 15 minutes after cooling has stopped. If the controller starts to call for cooling again the “compressor timeout” timer deactivates until cooling is called for again.

EUROTHERM 2704 Advanced Multi-loop Temperature Controllers

Specification:-

Analogue IP/OP In 8
Analogue IP/OP Out 8
Combinational Logic 32 Operations
Control Algorithms Cascade, Override, Single, User wired control
l loops 3
Digital Comms DeviceNet, Ethernet, Modbus, Profibus
Digital IP/OP In 44
Digital IP/OP Out 43
Maths Equation 32 Calculations
PC Configuration Graphical wiring
Special Features Carbon Potential, Humidity, Melt Pressure, Vacuum
Timers/Counters/Totals 4 / 0 / 4
Panel size (DIN) 1/4
Input Type mA, mV, RTD, TC, Volts
PV Accuracy <0.1%
IP Rating IP65
Display Type Dot Matrix
Control Types On/Off, PID, VP
Alarm Types Dev, Event, Heater fail, Hi, Lo
Supply Voltage 24V dc/ac, 85-264V ac
SP Programmer 60 Programmes, 600 Segments max
Real Time Clock Day and Time