  • Display method: 4-digit 7-segment LED.
  • Control method: ON/OFF control, P, PI, PD, PIDF, PIDS control.
  • Input specification : Thermocouple: K(CA), J(IC), E(CR), T(CC), R(PR), S(PR), N(NN), W(TT)
    RTD: DPt100Ω, JPt100Ω
  • Analog: 1-5VDC , 0-10VDC , DC4-20mA..
  • Sampling cycle: 500ms.
  • Control output : Relay(250VAC~ 3A).
  • Power supply : 100-240VAC~ 50/60Hz.

Description

Autonics Temperature Controllers TZ4ST-14R

Autonics Temperature Controllers

TZ Series-

Dual-Speed PID Temperature Controllers with Protection Cover (Discontinued)The TZ series temperature controllers are equipped with dual speed PID control for high-speed or high-precision temperature control. The temperature controllers feature ±0.3% high display accuracy, 2-step auto tuning function and supports up to 13 different types of inputs, providing outstanding temperature control at affordable costs.

Main features:-

The TZN/TZ series temperature controllers are equipped with dual speed PID control for high-speed or high-precision temperature control. The temperature controllers feature ±0.3% high display accuracy, 2-step auto tuning function and supports up to 13 different types of inputs, providing outstanding temperature control at affordable costs.

  • Dual-speed PID control
    • – High-speed response : minimizes time required to reach SV.
    • – Low-speed response : minimizes overshoot for sensitive temperature control.
  • High display accuracy : ±0.3% of full-scale value.
  • 2-step auto tuning function.
  • Various input types (13 total) : includes temperature sensor and analog inputs.
  • Various sub-output options-
    • – Various alarm outputs including loop break alarm and sensor break alarm.
    • – PV transmission output (DC 4-20mA).
    • – RS485 communication output.
  • Decimal point display function for analog inputs.

TZ4ST-14R

Data Sheet-

Display method 4-digit 7-segment LED
Control method ON/OFF control, P, PI, PD, PIDF, PIDS control
Input specification Thermocouple: K(CA), J(IC), E(CR), T(CC), R(PR), S(PR), N(NN), W(TT)
RTD: DPt100Ω, JPt100Ω
Analog: 1-5VDC , 0-10VDC , DC4-20mA
Sampling cycle 500ms
Control output Relay(250VAC~ 3A)
Option output Event 1
Power supply 100-240VAC~ 50/60Hz
Display accuracy F.S ± 0.3% or 3℃, select the higher one
Alarm output hysteresis 1 to 100℃ (0.1 to 100.0℃) variable
Proportional band 0.0 to 100.0%
Integral time 0 to 3,600 sec
Derivative time 0 to 3,600 sec
Control period 1 to 120 sec
LBA setting 1 to 999 sec
Ramp setting Ramp Up, Ramp Down: 1 to 99 min each
Environment_Ambient temperature -10 to 50℃, storage: -20 to 60℃
Environment_Ambient humidity 35 to 85% RH, storage: 35 to 85% RH
Weight Approx. 218g(approx. 162g)