Need help? Call us: 01326 708334, 01326 708335 or info@voltecbd.com
- input specification type 1/3
- no bouncing due to mechanical switches thanks to 3 ms input filter
- tool-free connection by direct plug-in technology for solid wire conductors
- space-saving use in the control cabinet
- direct connection of multi-channel sensors in 1-wire connection technology in the smallest space
- increased packing density with 16 connection points in the housing of a 12 mm terminal bloc
Proline Promag P 300 Electromagnetic Flowmeter, Proline Promag H 100 Electromagnetic Flowmeter, Proline Promag W 300 Electromagnetic Flowmeter,
Proline Promag W 400 Electromagnetic Flowmeter, Dosimag Electromagnetic Flowmeter, Proline Promag D 10 Electromagnetic Flowmeter,
Proline Promag E 100 Electromagnetic Flowmeter, Proline Promag H 200 Electromagnetic Flowmeter, Proline Promag H 300 Electromagnetic Flowmeter,
Proline Promag H 500 Electromagnetic Flowmeter, Proline Promag H 10 Electromagnetic Flowmeter, Proline Promag P 100 Electromagnetic Flowmeter,
Proline Promag P 200 Electromagnetic Flowmeter, Proline Promag P 500 Electromagnetic Flowmeter, Proline Promag P 10 Electromagnetic Flowmeter,
Proline Promag W 500 Electromagnetic Flowmeter, Proline Promag W 800 Electromagnetic Flowmeter, Proline Promag W 10 Electromagnetic Flowmeter,
Proline Promag W 500 Electromagnetic Flowmeter, Proline Promag 51W Electromagnetic Flowmeter, Proline Promag 55S Electromagnetic Flowmeter
Read more
TECHMICAL SUMMERY FOR WATSON MARLOW Quantum single-use bioprocessing pumps:
Min. flow rate | 5.33 ml/min |
Max. flow rate | 20 L/min |
Max. operating pressure | 3 bar |
Speed control ratio | 4000:1 |
Operating temperature range | 5 to 30 °C |
Operating temperature range | 41 to 86 °F |
Control types | Remote Analogue/Digital |
Standards | CE, cETLus, IEC 61010-1 |
Ingress rating | IP66, NEMA 12/13 |
Power supply | 100-120 V/200-240 V 1ph 50/60 Hz 250 VA |
The GWA-250-U0 dual limit value switch enables the parallel configuration of up to two switching
levels for continuous measurements without the installation of extra measurement equipment.
♦ The key coding switch allows for the simplest switching point change.
♦ Switchable input.
♦ Powering integrated converters.
Read more
Galvanic isolation, universal signal converter, and standard signal conversion.
♦ Installing is simple.
♦ Power supply that is universal.
♦ 3x isolated galvanic.
Read more
Pipe installation data logger with GSM data transmission, powered by a battery or an AC adapter.
♦ Installing in a 2" tube.
♦ Safety overflow.
♦ Using the most effective source for communication.
Read more
Hydrostatic level measurement using a level sensor with a 22mm diameter and a capacitive ceramic measuring cell
with an RS485 Modbus-RTU output signal.
♦ Reliable and efficient ceramic cell.
♦ Possible integrated temperature measurement.
♦ Low consumption of energy.
Read more
Independent data logger and IOT Gateway
♦Power supply options come in a variety of forms. ♦Using the most effective source for communication. ♦with up to 7 sensors and 12 measurement types. Pressure transmitter/pressure switch for typical applications with data memory Monitoring of gases, vapors, liquids, and dust at absolute or relative pressures.
With ceramic front-flush or internal diaphragm
With TFT-display, 4-20mA or 0-10V output and up to 4 pnp switching outputs.
♦ Color display and full text programming.
♦ Ceramic cell that is precise and stable.
♦ 500 000 measuring point data logger.
Read more
Ultrasonic flowmeter
✓ Suitable for use with both conductive and non-conductive liquids. ✓ Due to the seal-free sensor, there is high process safety. ✓ The measurement tube can move easily.MODEL:-F630
Magnetic inductive flowmeter, small or separate ✓ The suitable device for every application, with a wide range of options. ✓ Possible spared variation. ✓ ATEX-Authorization. ✓ Applications for hygiene. ✓ Mechanism for detecting errors.Multivariable, simple, and user-friendly smart magmeter for utilities
♦ Decent design.
♦ Enclosed control panel.
♦ Parameterization is possible via Bluetooth.
Flow switch and transmitter for basic industrial, sanitary, and aseptic applications.
♦ Applications for hygiene.
♦ Compact design.
♦ Speed of response.
Read more
♦ Installing a simple pressurized system is possible.
♦ High precision.
♦ Very little pressure drop.
Read more
♦ Quick response.
♦ Operator comfort is improved through display and operation on-site.
♦ Wireless.
Read more
♦Comprising a measurement portion, compressed air, and gas meter.
♦ Simple and affordable installation.
♦ Owing to its excellent accuracy, it is suitable for measuring leaks.
Read more
The EK1100 EtherCAT Coupler is the link between the EtherCAT protocol at the fieldbus level and the EtherCAT Terminals. The coupler converts the passing telegrams from Ethernet 100BASE-TX to E-bus signal representation. A station consists of a coupler and any number of EtherCAT Terminals that are automatically detected and individually displayed in the process image.
Read more

Voltec Engineering Limited
Automation and control products are the focus of VOLTEC ENGINEERING LIMITED. In the area of comprehensive industry solutions for alteration, upgrading, and new construction projects, VOLTEC ENGINEERING LIMITED is a one-stop solution provider.
Need Help?
01326 708335
01329 727092
Customer Service
© 2023 Voltec Engineering Ltd. | Design & Developed by mPair Technologies Ltd.