WAROM Series Explosion-Proof Plug and Sockets BCZ8060
◆ Explosion protection to EN, IEC
◆ Can be used in Zone 1,2,21,22 -Class I Division 2- Groups A, B, C, D
◆ 2P,3P,4P and 5P.
◆ Only the switch in the socket cut off can plug be pulled out, power after inserting the plug.
GRP(glass fiber-reinforced polyester resin)
Description
WAROM Series Explosion-proof Plug and Sockets-BCZ8060
Explosion-proof Plug Sockets
Application
◆ Widely used on various marine platforms, chemical tankers, LNG ships, and dangerous cargo wharves for electric connection;
◆ Can reliably work in severe environments where is easily affected by moisture, vibration, or corrosion;
◆ Explosive hazardous atmosphere Zone 1, Zone 2, Zone 21, Zone 22.
Specification:-
| Compliance | IEC60079, EN60079, GB3836, GB12476,CCS standard | |||
| Ex-Mark | Ex d e IIC T6 Gb/ Ex d e IIC T4 Gb/Ex tD A21 IP66 T80℃ | |||
| Rated current | 10A、16A /20A、32A /50A、60A、63A /100A、125A | |||
| Degree of protection | IP66 | |||
| Corrosion-proof | WF2 | |||
| Inlet thread | 1×M25×1.5 | 1×M40×1.5 | 1×M50×1.5 | 2×M63×1.5 |
| Cable outer diameter of plug or connector | Suitable for cable of Φ8~Φ14mm(2P, 3P) Suitable for cable of Φ8~Φ16mm(4P, 5P) | Suitable for cable of Φ9~Φ19mm. | Suitable for the cable of Φ19~Φ26mm. | Suitable for the cable of Φ19~Φ28mm. |
| Cable outer diameter of socket | The cable of the socket is according to the selected DQM cable gland. | |||
| global (IECEx) | IECEx CNEX 21.0004X |
| Gas and dust | x db eb IIC T6 Gb
Ex tb IIIC T80℃ Db IP66 |
| Europe (ATEX) | CNEX 21 ATEX 0003X |
| Gas and dust | II 2 G Ex db eb IIC T6 Gb
|
| Certificates | IECEx; ATEX; CU-TR |
| Conformity to standards | N;IEC |
| Degree of protection | IP66 |
| Ambient temperature | -20℃~+55℃ |
DATA:-
| Material | GRP(glass fibre-reinforced polyester resin) |
| Weight | 0.35kg~1.5kg |
| Dimensions | As per design |
| Enclosure colour | Black |
| Exposed fastener | Stainless steel |
| Rated voltage | DC 36V, 24V |
| Rated current | 10A,16A |
| Cross section of cable | 2.5~4mm2 |
| Cable entries | Standard 1 x M25x1.5 cable gland(plastic), 1 x M25x1.5 plug (plastic) |
| Cable gland(optional) | DQM-I(Ex e) |

II 2 G Ex db eb IIC T6 Gb
II 2 D Ex tb IIIC T80℃ Db IP66