VIPA PLC 313-5BF23-CPU313SC
- SPEED7 technology.
- 24 Digital Inputs.
- 16 Digital Outputs.
- 5 Analog Inputs.
- 2 Analog Outputs.
- 1 Analog Input Pt100, included.
- 3x Counter.
- 3x PWM.
- 256… 1.024 work memory [KB].
- Interface [RJ45]: Ethernet PG/OP communication.
- Interface [2x RS485]: MPI, PtP: ASCII, STX/EXT, 3964(R), USS master, Modbus master/slave.
- SD/MMC card slot with locking.
Description
VIPA PLC 313-5BF23-CPU313SC
Features:-
- Powered by SPEED7.
- Work memory [KB]: 256…1.024.
- Onboard 24x DI / 16x DO / 5x AI [current/voltage] / 2x AO / 1x Pt100 / 3x Counter / 3x PWM.
- Interface [RJ45]: Ethernet PG/OP communication.
- Interface [2x RS485]: MPI, PtP: ASCII, STX/ETX, 3964(R), USS master, Modbus master/slave.
- Including front connectorSD/MMC card slot with locking, up to 8 modules stackable, programmable with WinPLC7, SIMATIC Manager and TIA Portal.
Technical data power supply:-
| Power supply (rated value) | DC 24 V |
| Power supply (permitted range) | DC 20.4…28.8 V |
| Reverse polarity protection | yes |
| Current consumption (no-load operation) | 240 mA |
| Current consumption (rated value) | 700 mA |
| Inrush current | 11 A |
| I²t | 0.7 A²s |
| Max. current drain at backplane bus | 3A |
| Max. current drain load supply | – |
| Power loss | 14 W |
VIPA PLC 313-5BF23-CPU313SC
Technical data digital inputs:-
| Number of inputs | 24 |
| Cable length, shielded | 1000 m |
| Cable length, unshielded | 600 m |
| Rated load voltage | DC 24 V |
| Reverse polarity protection of rated load voltage | yes |
| Current consumption from load voltage L+ (without load) | 70 mA |
| Rated value | DC 24 V |
| Input voltage for signal “0 | DC 0…5 V |
| Input voltage for signal “1” | DC 15…28.8 V |
| Input voltage hysteresis | – |
| Signal logic input | Sinking input |
| Frequency range | – |
| Input resistance | – |
| Input current for signal “1” | 6 mA |
| Connection of Two-Wire-BEROs possible | yes |
| Max. permissible BERO quiescent current | 1.5 mA |
| Input delay of “0” to “1” | 0.1 / 0.35 ms |
| Input delay of “1” to “0” | 0.1 / 0.35 ms |
| Number of simultaneously utilizable inputs horizontal configuration | 24 |
| Number of simultaneously utilizable inputs vertical configuration | 24 |
| Input characteristic curve | IEC 61131-2, type 1 |
| Initial data size | 3 Byte |
Technical data digital outputs:-
| Number of outputs | 16 |
| Cable length, shielded | 1000 m |
| Cable length, unshielded | 600 m |
| Rated load voltage | DC 24 V |
| Reverse polarity protection of rated load voltage | – |
| Current consumption from load voltage L+ (without load) | 100 mA |
| Total current per group, horizontal configuration, 40°C | 3A |
| Total current per group, horizontal configuration, 60°C | 2A |
| Total current per group, vertical configuration | 2A |
| Output voltage signal “1” at min. current | L+ (-0.8 V) |
| Output voltage signal “1” at max. current | L+ (-0.8 V) |
| Output current at signal “1”, rated value | 0.5 A |
| Signal logic output | Sourcing output |
| Output current, permitted range to 40°C | 5 mA to 0.6 A |
| Output current, permitted range to 60°C | 5 mA to 0.6 A |
| Output current at signal “0” max. (residual current) | 0.5 mA |
| Output delay of “0” to “1” | 100 µs |
| Output delay of “1” to “0” | 100 µs |
| Minimum load current | – |
| Lamp load | 5W |
| Parallel switching of outputs for redundant control of a load | possible |
| Parallel switching of outputs for increased power | not possible |
| Actuation of digital input | yes |
| Switching frequency with resistive load | max. 2.5 kHz |
| Switching frequency with inductive load | max. 0.5 Hz |
| Switching frequency on lamp load | max. 2.5 kHz |
| Internal limitation of inductive shut-off voltage | L+ (-52 V) |
| Short-circuit protection of output | yes, electronic |
| Trigger level | 1A |
| Number of operating cycle of relay outputs | – |
| Switching capacity of contacts | – |
| Output data size | 2 Byte |
DATA SHEET-PDF