RAYTEK Infrared Temperature Sensor RAYCMLTJ
The CM is a potent, small, integrated infrared sensor that is intended for continuous temperature monitoring. If your application is sensitive to noise, it can simply replace standard contact probes with a user-scaleable 0-5V output or a J-type or K-type thermocouple output.
Description
RAYTEK Infrared Temperature Sensor RAYCMLTJ
Raytek RAYCMLTJ Infrared Temperature Sensor with RS232, Type J Output, 1m Cable, 0.75-16UNF Thread Scaleable 0-5 V, type J or K output
CM Highlights-
■ Wide -20°C to 500°C (-4°F to 932°F) temperature range.
■ Rugged IP 65 (NEMA-4) stainless steel housing.
■ Rugged 13:1 optics at 90% energy.
■ 150 mSec (95%) response time.
■ Alarm output.
■ Sensor status/self diagnostic indicator LED.
■ RS232 digital communications for sensor set-up and monitoring.
■ Adjustable signal processing.
■ DataTemp® Multidrop software compatible.
■ Accessories for air purging and lens protection.
Measurement Specifications:-
| Temperature Range | -20ºC to 500ºC (-4ºF to 932ºF) |
| Accuracy (mV) | ± 1.5% of reading or ± 2ºC, whichever is greater 1,2 |
| Accuracy (t/c) | ± 1.5% of reading ± 2ºC or ± 4ºC,
whichever is greater1,2,3 |
| Spectral Response | 8 to 14 microns |
| Repeatability (digital and voltage)
Repeatability (t/c) |
± 0.5% of reading or ± 2ºC, whichever is greater
± 0.5% of reading or ± 2ºC, whichever is greater |
| Temperature Resolution | 0.1°C |
| Response Time (95%) | 150 mSec |
| Emissivity | 0.10 to 1.10 (adjustable) |
| Transmissivity | 0.10 to 1.00 (adjustable) |
| Signal Processing | Peak hold, valley hold, variable averaging |
| Self-diagnostics/sensor status | Normal operation, alarm, out of range, unstable, sensor fault |
| Bore-Sight tolerance 4 | 3º @ focal point |
1 .Accuracy from -20 to 0ºC is ±3.5ºC (Digital and voltage), ± 5.5ºC (t/c).
2.Accuracy and resolution specifications are valid for ambient temperature 23ºC ± 5ºC, e = 0.95 and calibration geometry.
3. Accuracy measured on the 0-5 VDC output or RS232 for t/c models is ± 1.5% of reading or ± 2ºC, whichever is greater.
4.Typical values measured at focal distance.
Electrical Specifications:-
| Analog Outputs | Model specific Type J, Type K or scaleable 0-5V voltage output |
| Cable Length | 1m (3.3 ft) standard
3m (9.8 ft) cables optional |
| Thermocouple
Output Impedance |
100 ohms |
| Voltage Output
Minimum Load Impedance |
50K ohms |
| Power Supply | 24 VDC ±20% @ 20mA |
| Digital Output 5 | Two-way RS232 digital output |
| Alarm Output 5 | Transistor, 24VDC @ 20mA |
5 Digital output and alarm output share a common wire. User selects either alarm output or RS232 communication via