IFM Photoelectric Distance Sensor O1D155
01.Applications:-
- The optical distance sensor measures distances between 0.3 and 6 m.
- It has a background suppression at > 6…100 m.
- The measured value is shown in a 10-segment display.
- According to the set output functions 2 output signals can be generated.
02.Functions :-
♦ Output function hysteresis:- The hysteresis keeps the switching state of the output stable if the measured value varies about the sensing range. Both outputs (OUT1 and OUT2) can be set as hysteresis function. → 10.2.4 Hysteresis function.
♦ Output function window:- The window function enables the monitoring of a defined acceptable range. Both outputs (OUT1 and OUT2) can be set as window function. → 10.2.6 Window function.
♦ Analogue output function :-The sensor can also output an analogue signal on output 2 (OUT2) which is proportional to the distance. → 10.2.11 Scaling of the measuring range (analogue output).
♦ Switch off the laser :-For safety and maintenance purposes the laser of the unit can be temporarily switched off via the input on pin 5.
IFM Photoelectric Distance Sensor
TECHNICAL DATA:-
Product characteristics
| Type of light |
red light |
| Laser protection class |
1 |
| Housing |
rectangular |
Electrical data
| Operating voltage [V] |
18…30 DC |
| Current consumption [mA] |
< 150 |
| Protection class |
III |
| Reverse polarity protection |
yes |
| Type of light |
red light |
| Wave length [nm] |
650 |
| Typ. lifetime [h] |
50000 |
Inputs / outputs
| Number of inputs and outputs |
Number of digital outputs: 2; Number of analogue outputs: 1 |
Outputs
| Total number of outputs |
2 |
| Electrical design |
PNP |
| Number of digital outputs |
2 |
| Output function |
normally open / normally closed; (programmable) |
| Max. current load per output [mA] |
200 |
| Number of analogue outputs |
1 |
| Analogue current output [mA] |
4…20; (IEC 61131-2) |
| Max. load [Ω] |
250 |
| Analogue voltage output [V] |
0…10; (IEC 61131-2) |
| Min. load resistance [Ω] |
5000 |
| Short-circuit protection |
yes |
| Type of short-circuit protection |
pulsed |
| Overload protection |
yes |
Detection zone
| Max. light spot width [mm] |
8 |
| Max. light spot height [mm] |
8 |
| Light spot dimensions refer to |
6 m |
| Background suppression [m] |
6…100 |
Measuring/setting range
| Measuring range [m] |
0.3…6; (white paper 200 x 200 mm 90% remission) |
| Sampling rate [Hz] |
1…33 |
Interfaces
| Communication interface |
IO-Link |
| Transmission type |
COM2 (38,4 kBaud) |
| IO-Link revision |
1.1 |
| SDCI standard |
IEC 61131-9 |
| Profiles |
Smart Sensor: Sensor Identification; Binary Data Channel, Process Value; Sensor Diagnosis |
| SIO mode |
yes |
| Required master port type |
A |
| Process data analogue |
2 |
| Process data binary |
2 |
| Min. process cycle time [ms] |
6 |
| Supported DeviceIDs |
| Type of operation |
DeviceID |
| Default |
812 |
|
Operating conditions
| Ambient temperature [°C] |
-10…60 |
| Protection |
IP 67 |
Tests / approvals
| EMC |
|
| Laser protection class |
1 |
| Notes on laser protection |
| Caution: |
laser light |
| laser class: |
1 |
|
EN / IEC60825-1:2007 |
|
EN / IEC60825-1:2014 |
|
Complies with 21 CFR 1040 except for deviations pursuant to Laser Notice No. 50, dated June 2007. |
|
| MTTF [years] |
186 |
Mechanical data
| Weight [g] |
310.5 |
| Housing |
rectangular |
| Dimensions [mm] |
59 x 42 x 52 |
| Materials |
housing: diecast zinc; front pane: glass; LED window: PC |
Displays / operating elements
| Display |
| switching status |
2 x LED, yellow |
| operation |
LED, green |
| distance value, programming |
alphanumeric display, 4-digit |
|
Remarks
| Remarks |
| operating voltage “supply class 2” according to cULus |
|
| Pack quantity |
1 pcs. |
Electrical connection
| Connection |
Connector: 1 x M12; coding: A |