Description
EUCHNER Electromechanical Safety Switches With Guard Locking
Safety switch NZ.VZ.VSE (guard locking, open-circuit current principle)
EUCHNER Electromechanical Safety Switches With Guard Locking-
SIMILAR MODEL:-
NZ1VZ-2131E3VSE07-M.
NZ1VZ-2131E3VSM04-M.
NZ1VZ-2131E3VSM07-M.
NZ1VZ-3131E3VSE04-M.
NZ1VZ-3131E3VSE09-M.
NZ1VZ-3131E3VSM04-M.
NZ1VZ-528E3VSE04-M.
NZ1VZ-528E3VSE04L060-M.
NZ1VZ-528E3VSE07-M.
NZ1VZ-528E3VSE09-M.
NZ1VZ-528E3VSE09L220-M.
NZ1VZ-528E3VSM04-M.
NZ1VZ-528E3VSM04L060-M.
NZ1VZ-528E3VSM04L220-M.
NZ1VZ-528E3VSM07-M.
NZ1VZ-528E3VSM09-M.
NZ1VZ-528E3VSM09L220-M
NZ1VZ-538E3VSE04-M.
NZ1VZ-538E3VSE04L060-M.
EUCHNER Electromechanical Safety Switches With Guard Locking-
Technical data:-
Electrical connection values:-
Connection cross section |
0.34 … 1.5 mm² |
Rated insulation voltage Ui |
|
AC/DC |
250 V |
Rated impulse withstand voltage Uimp |
2.5 kV |
Utilization category |
|
AC-15 |
4 A 230 V |
DC-13 |
4 A 24 V |
Short circuit protection according to IEC 60269-1 |
4A gG |
Solenoid operating voltage |
|
DC |
24 V -15% … 10% |
Switching voltage |
|
min. at 10 mA |
12 V |
Switching current |
|
min. at 24 V |
1 mA |
thermal rated current Ith |
4 A |
EUCHNER Electromechanical Safety Switches With Guard Locking-
Mechanical values and environment-
Approach speed |
max. 20 m/min |
Approach direction |
A |
Connection type |
|
1 x |
M20 x 1.5 |
Number of door position NO contacts |
1 |
Number of door position positively driven contacts |
3 |
Extraction force |
40 N |
Actuation frequency |
max. 1200 1/h |
Actuating force |
45 N |
Installation orientation |
any |
Insertion depth |
52 mm |
Solenoid alignment |
3 |
Mechanical life |
2 x 10⁶ |
Retention force |
35 N |
Switching principle |
Slow-action switching contact |
Degree of protection |
IP65 |
Ambient temperature |
-25 … +80 °C |
Material |
|
Housing |
Anodized die-cast alloy |
Contact |
Silver alloy, gold flashed |
Locking force Fmax |
2000 N |
Locking force FZh |
1500 N |
Guard locking principle |
Open-circuit current principle |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
|
Control of guard locking |
Category |
Depending on external control of guard locking |
Performance Level |
Depending on external control of guard locking |
PFHD |
Depending on external control of guard locking |
|
Monitoring of the guard position |
B10D |
4.5 x 10⁶ |
In combination with actuator ACTUATOR-Z-GN-
In combination with actuator ACTUATOR-Z-G-