Need help? Call us: 01326 708334, 01326 708335 or info@voltecbd.com
- Detection of luminescent objects and markings
- Various filter options
- Various light spot sizes
- High switching frequency
- Detection of luminescent objects and markings
- Various filter options
- Various light spot sizes
- High switching frequency
- Detection of luminescent objects and markings
- Various filter options
- Various light spot sizes
- High switching frequency
- Detection of luminescent objects and markings
- Various filter options
- Various light spot sizes
- High switching frequency
- Special Version: Autocollimation
- Application: Detection Of Red Mark
- Operating Range: 0 - 0.35m
- Detection of luminescent objects and markings
- Various filter options
- Various light spot sizes
- High switching frequency
- Special Version: Autocollimation
- Switching Output: Transistor, PNP
- Rotatable M12 connector
- Operating range, max.: 0 - 0.4 m
- Application: Detection of any kind of luminescence, Detection of white paper
Offering a range of encoder from basic to the programmable. Datalogic encoders offer dimension reduction, without compromising robustness and overall performance.
ENC41-H06-0100-C15, ENC41-H06-0360-C15, ENC41-H06-0500-C15,ENC41-H06-1000-C15, ENC41-H06-1024-C15,ENC41-H06-2048-C15, ENC41-H06-4096-C15, ENC41-S06-0100-C15, ENC41-S06-0360-C15, ENC41-S06-0500-C15,ENC41-S06-1000-C15, ENC41-S06-1024-C15, ENC41-S06-2048-C15, ENC41-S06-4096-C15, FAC06-06,FBC06-06
Read more
Electrical data:
Connection terminals: 0.14 ÷ 2.5 mm2 (AWG 26 ÷ 14)
Cable entry:Cable gland: M20x1.5 with cable sheath diameter 6÷12mm CONDUIT: NPTx½ o NPT3/4
Output activation delay: Rods free → Rods covered: c.a. 1 sec Rods covered → Rods free c.a. 1... 2 sec
Detection fuctions FSH/FSL: Settable on the circuit with selector switch
Vibration frequency: [Hz] 200 c.a.
Over voltage category: II
Pollution degree: 2 (inside housing)
Operative Conditions:
Ambient temperature: [°C] -40 ÷ +60
Process temperature-Tc: [°C] -40 ÷ +150
Ventilation:Ventilation is not required
Min. powder density: [g/l] Setting A : c.a. 150 - Setting B : c.a. 30
Features of bulk material: No strong tendency to cake or deposit. Max grain size 8 mm
Max. mechanical load: [N] 500 laterally on vibrant rods
Max. process pressure: [Bar] 16
Vibration: c.a. 200
Relative humidity: 0 ÷ 100%, suitable for outdoor use
Altitude: [m] max 2.000