TECHNICAL SUMMERY OF WATSON MARLOW 100 SERIES CASED PUMP:
| Max. flow rate | 190 ml/min |
| Min. flow rate | 0.0001 ml/min |
| Max. flow rate | 3.04 USGPH |
| Min. flow rate | 0.00002 USGPH |
| Max. operating pressure | 2 bar |
| Max. operating pressure | 30 psi |
| Speed control ratio | 100:1, 1000:1, 200:1, 2000:1, 32:1, 320:1 |
| Operating temperature range | 5 to 40 °C |
| Operating temperature range | 40 to 104 °F |
| Standards | CE, cETLus |
| Ingress rating | IP31, NEMA 2 |
| Power supply | Supplied with 24 VDC mains transformer plug (range 90-264 VAC 47-63 Hz) which comes with multi-country adaptors |
Product ID: 751102.
PNOZsigma safety relay (standalone), inputs: 1-channel wiring without detection of shorts across contacts, manual/automaticstart, outputs: 3 N/O, 1 N/C, 1 SC, UB 24 V DC, width: 17.5 mm, plug-in spring-loaded terminals, monitoring of E-STOP, safety gates.
Read more
PNOZsigma contact expansion, outputs: 4 N/O, 1 N/C, UB 24 V DC, width: 17.5 mm, plug-in screw terminals, contact block for contact expansion in connection with safety-related control components.
Read more
Core features
- Available in NEMA 1, 3R, 4, 4X, 12 enclosures for a broad range of application environments.
- Most common disconnect switches in stock and ship within 24 hours with QuikShip Everyday Service to meet project requirements.
- Multiple field-installed accessories enhance the enclosed disconnect switches to fit the desired application.
- UL 508 Listed for motor disconnect applications.
- 3- and 6-Pole UL 508 motor disconnect switches provide flexibility for single or dual motor applications.
- NEMA 4X 30A and 60A motor control disconnects.
Eaton Bussmann series CCP compact circuit protector, Compact Circuit Protector, 30 A, Single-pole, 20 lb-in, Class G, Screw with pressure plate, Front panel, 240 V.
Read more
Product ID: 750105.
PNOZsigma safety relay (standalone), inputs: 1/2-channel wiring with/
without detection of shorts across contacts, manual/automatic start,
outputs: 2 N/O, 2 N/O t-d (t = 0.04 - 300 s), 1 SC, UB = 24 V DC, width:
22.5 mm, plug-in screw terminals, monitoring of E-STOP, safety gates, light
curtain.