- input specification type 1/3
- no bouncing due to mechanical switches thanks to 3 ms input filter
- tool-free connection by direct plug-in technology for solid wire conductors
- space-saving use in the control cabinet
- direct connection of multi-channel sensors in 1-wire connection technology in the smallest space
- increased packing density with 16 connection points in the housing of a 12 mm terminal bloc
FA 500 - Dew point sensor with integrated display and alarm relay
- Dew point sensor FA 500 from -80 to 20°Ctd.
- For refrigeration, membrane, and desiccant dryers, the FA 500 is the perfect dew point sensor with an integrated display and warning relay.
FA 550 - Dew point sensor in robust die-cast aluminum housing
✓Robust dew point sensor for gases and compressed air
✓ The Dew point FA 550 is perfectly suited for measuring dew points outside and reliably does so even in punishing industrial settings.
✓Dew point measurement after adsorption dryers, membrane dryers, or refrigeration dryer in compressed air systems.
Read more
TCN4S-24R
- Display method : 4-digit 7-segment LED
- Control method : ON/OFF, P, PI, PD, PID
- Input specification : Thermocouple: K(CA), J(IC), T(CC), R(PR), S(PR), L(IC) RTD: DPt100Ω, Cu50Ω
- Sampling cycle : 100ms
- Control output : Relay(250VAC~ 3A) or SSR drive(12VDC ) [ON/OFF]
- Power supply : 100-240VAC~ 50/60Hz
- Display method : 4-digit 7-segment LED.
- Control method : ON/OFF, P, PI, PD, PID.
- Input specification : Thermocouple: K(CA), J(IC), E(CR), T(CC), B(PR), R(PR), S(PR), N(NN), C(TT), G(TT), L(IC), U(CC), Platinel II. RTD: DPt100Ω, DPt50Ω, JPt100Ω, Cu100Ω, Cu50Ω, Nikel 120Ω. Analog: 0-100mV, 0-5V, 1-5V, 0-10V. 0-20mA, 4-20mA.
- Sampling cycle : 50ms.
- Control output 1 : Current(DC0/4-20mA) or SSR drive(11VDC
) [ON/OFF].
- Option output : Alarm 1, RS485 comm.
- Power supply : 100-240VAC~ 50/60Hz.
- Protection structure : IP65(front panel).
- Display method: 4-digit 7-segment LED.
- Control method: ON/OFF control, P, PI, PD, PIDF, PIDS control.
- Input specification : Thermocouple: K(CA), J(IC), E(CR), T(CC), R(PR), S(PR), N(NN), W(TT) RTD: DPt100Ω, JPt100Ω
- Analog: 1-5VDC , 0-10VDC , DC4-20mA..
- Sampling cycle: 500ms.
- Control output : Relay(250VAC~ 3A).
- Power supply : 100-240VAC~ 50/60Hz.
Temp Control, 1/4 DIN, Zone PID, RS485, 100-240VAC; Fixed Control, 4 Alarm, Current/SSR Drive Out1&2, 1 CT+3 Digital Input,
Read more
The EK1100 EtherCAT Coupler is the link between the EtherCAT protocol at the fieldbus level and the EtherCAT Terminals. The coupler converts the passing telegrams from Ethernet 100BASE-TX to E-bus signal representation. A station consists of a coupler and any number of EtherCAT Terminals that are automatically detected and individually displayed in the process image.
Read more

Voltec Engineering Limited
Automation and control products are the focus of VOLTEC ENGINEERING LIMITED. In the area of comprehensive industry solutions for alteration, upgrading, and new construction projects, VOLTEC ENGINEERING LIMITED is a one-stop solution provider.
Need Help?
01326 708335
01329 727092
Customer Service
© 2023 Voltec Engineering Ltd. | Design & Developed by mPair Technologies Ltd.