Need help? Call us: 01326 708334, 01326 708335 or info@voltecbd.com
Technical Specification:
Process Connection | CLEANadapt │ Tri-Clamp │ Varivent │ FLEXadapt ESF │ Thread | Without thread |
Insertion length | 0…2000 mm (flush version available) |
Wetted material | Stainless steel 1.4404 (AISI 316L) │ PEEK (Dependent on type ) |
Measuring range | -200 °C …+400 °C |
Accuracy | < ±0.1 °C/°F |
Available versions | Head Ø18 mm │ Spacer │ Transmitter |
Operating pressure | max. 50 bar | 10 bar (Dependent on type ) |
Communication | 4…20 mA, IO-Link |
Core features
- Available in NEMA 1, 3R, 4, 4X, 12 enclosures for a broad range of application environments.
- Most common disconnect switches in stock and ship within 24 hours with QuikShip Everyday Service to meet project requirements.
- Multiple field-installed accessories enhance the enclosed disconnect switches to fit the desired application.
- UL 508 Listed for motor disconnect applications.
- 3- and 6-Pole UL 508 motor disconnect switches provide flexibility for single or dual motor applications.
- NEMA 4X 30A and 60A motor control disconnects.
Eaton Bussmann series CCP compact circuit protector, Compact Circuit Protector, 30 A, Single-pole, 20 lb-in, Class G, Screw with pressure plate, Front panel, 240 V.
Read more
The CP-9302-702 electronic actuator drive processes a variable input signal from a controller to provide proportional control of an electric actuator. The CP-930-702 is preset for current input (4 - 20 mA) and has additional wiring for connection to an override switch for applications requiring an external override of the input signal. The CP-9302-702 is equipped with built-in jumpers and adjustable potentiometers, so that the type of input signal, deadband, input span, and start point may be readjusted in the field when necessary.
Read more
In order to avoid the pricey installation of two or more separate devices, the Rosemount 8800 MultiVariable Vortex Flow Meter integrates temperature and flow sensors into a single, extremely precise instrument. The integrated, detachable temperature sensor, which is isolated from the process and distinct from the Vortex flow sensor, delivers a precise process temperature measurement. It also offers temperature and pressure compensation, providing compensated mass flow and corrected volume in steam and liquid applications when the input comes from an external HART® pressure transmitter.

Voltec Engineering Limited
Automation and control products are the focus of VOLTEC ENGINEERING LIMITED. In the area of comprehensive industry solutions for alteration, upgrading, and new construction projects, VOLTEC ENGINEERING LIMITED is a one-stop solution provider.
Need Help?
01326 708335
01329 727092
Customer Service
© 2023 Voltec Engineering Ltd. | Design & Developed by mPair Technologies Ltd.