Need help? Call us: 01326 708334, 01326 708335 or info@voltecbd.com
Electrical data:
Connection terminals: 0.14 ÷ 2.5 mm2 (AWG 26 ÷ 14)
Cable entry:Cable gland: M20x1.5 with cable sheath diameter 6÷12mm CONDUIT: NPTx½ o NPT3/4
Output activation delay: Rods free → Rods covered: c.a. 1 sec Rods covered → Rods free c.a. 1... 2 sec
Detection fuctions FSH/FSL: Settable on the circuit with selector switch
Vibration frequency: [Hz] 200 c.a.
Over voltage category: II
Pollution degree: 2 (inside housing)
Operative Conditions:
Ambient temperature: [°C] -40 ÷ +60
Process temperature-Tc: [°C] -40 ÷ +150
Ventilation:Ventilation is not required
Min. powder density: [g/l] Setting A : c.a. 150 - Setting B : c.a. 30
Features of bulk material: No strong tendency to cake or deposit. Max grain size 8 mm
Max. mechanical load: [N] 500 laterally on vibrant rods
Max. process pressure: [Bar] 16
Vibration: c.a. 200
Relative humidity: 0 ÷ 100%, suitable for outdoor use
Altitude: [m] max 2.000
Read more
Special Features:
■ Reliable and cost-effective ■ Design per EN 837-1 or ASME B40.100 ■ Nominal size 40 [1 ½"], 50 [2"], 63 [2 ½"], 80 [3"], 100 [4"] and 160 [6"] ■ Scale ranges to 0 ... 400 bar [0 ... 6,000 psi]Model: 111.12, back mount
Model: 111.10, lower mount (radial)
KOBOLD room thermostats are suitable for industrial plants, greenhouses, and warehouses, and also for monitoring the maximum temperature in switchgear cabinets and relay stations. Room thermostats are supplied with TER-H 1 wall brackets.
Switching range:- -20 ... +20 ... +80 ... +130°C, adjustable. Material:-aluminum (housing). copper, brass, or stainless steel (probe). Micro switch:- SPDT max. 250 VAC, 8 (5) A at 250 VAC, 8 A at 24 VDC. Pitot tube sensors are classified as differential pressure sensors for flow measurement.
Connection: G1 ... G 1½, 1 ... 1½" NPT, DN25 ... 80, ANSI 1 ... 3".
Material: stainless steel.
pmax: 400 bar.
tmax: 1175 °C.
Probe length: 50 ... 8000 mm (2" ... 600").
Read more
SFB Technology (Selective Fuse Breaking), Screw connection, DIN rail mounting, Primary-switched Power Supply Unit by QUINT POWER, Input: 1-Phase, Output: 24 V DC / 20 A.
Read more
Applications
■ Calibration service companies and service industry.
■ Measurement and control laboratories.
■ Pressure tests.
Special features
■ Digital indicator with interchangeable pressure sensors (plug-and-play).
■ Measuring ranges 0 ... 1,000 bar [0 ... 14,500 psi].
■ Type of pressure: Positive and negative overpressure,absolute pressure and differential pressure.
■ Accuracy: 0.2 %, optionally 0.1 % (incl. calibration certificate).
■ Data logger for recording measured values.
Read more
Primary-switched STEP POWER power supply for DIN rail mounting, input: 1-phase, output: 12 V DC/3 A