Need help? Call us: 01326 708334, 01326 708335 or info@voltecbd.com
With retro-reflective sensors, the transmitter and receiver are located in one housing and combined with a prismatic reflector. The reflector reflects the emitted light beam and if the light is interrupted by an object, the sensor switches.
Read more
TCN4S-24R
- Display method : 4-digit 7-segment LED
- Control method : ON/OFF, P, PI, PD, PID
- Input specification : Thermocouple: K(CA), J(IC), T(CC), R(PR), S(PR), L(IC) RTD: DPt100Ω, Cu50Ω
- Sampling cycle : 100ms
- Control output : Relay(250VAC~ 3A) or SSR drive(12VDC ) [ON/OFF]
- Power supply : 100-240VAC~ 50/60Hz
- Display method : 4-digit 7-segment LED.
- Control method : ON/OFF, P, PI, PD, PID.
- Input specification : Thermocouple: K(CA), J(IC), E(CR), T(CC), B(PR), R(PR), S(PR), N(NN), C(TT), G(TT), L(IC), U(CC), Platinel II. RTD: DPt100Ω, DPt50Ω, JPt100Ω, Cu100Ω, Cu50Ω, Nikel 120Ω. Analog: 0-100mV, 0-5V, 1-5V, 0-10V. 0-20mA, 4-20mA.
- Sampling cycle : 50ms.
- Control output 1 : Current(DC0/4-20mA) or SSR drive(11VDC
) [ON/OFF].
- Option output : Alarm 1, RS485 comm.
- Power supply : 100-240VAC~ 50/60Hz.
- Protection structure : IP65(front panel).
- Display method: 4-digit 7-segment LED.
- Control method: ON/OFF control, P, PI, PD, PIDF, PIDS control.
- Input specification : Thermocouple: K(CA), J(IC), E(CR), T(CC), R(PR), S(PR), N(NN), W(TT) RTD: DPt100Ω, JPt100Ω
- Analog: 1-5VDC , 0-10VDC , DC4-20mA..
- Sampling cycle: 500ms.
- Control output : Relay(250VAC~ 3A).
- Power supply : 100-240VAC~ 50/60Hz.
SFB Technology (Selective Fuse Breaking), Screw connection, DIN rail mounting, Primary-switched Power Supply Unit by QUINT POWER, Input: 1-Phase, Output: 24 V DC / 20 A.
Read more
Temp Control, 1/4 DIN, Zone PID, RS485, 100-240VAC; Fixed Control, 4 Alarm, Current/SSR Drive Out1&2, 1 CT+3 Digital Input,
Read more
The EK1100 EtherCAT Coupler is the link between the EtherCAT protocol at the fieldbus level and the EtherCAT Terminals. The coupler converts the passing telegrams from Ethernet 100BASE-TX to E-bus signal representation. A station consists of a coupler and any number of EtherCAT Terminals that are automatically detected and individually displayed in the process image.