WATSON MARLOW 600 SERIES CASED PUMP

Add to Wishlist
Add to Wishlist

Technical Summary

Max. flow rate 18 L/min
Min. flow rate 0.001 L/min
Max. flow rate 301 USGPH
Min. flow rate 0.02 USGPH
Drive speed control ratio 2650:1
Operating temperature range 5 to 40 °C
Operating temperature range 41 to 104  °F
Control types EtherNet/IP™, Profibus®, Profinet®, Remote Analogue/Digital, RS232, RS485, SCADA
Drive standards CE, cETLus, C-Tick, IRAM, NSF/ANSI 61 (for Marprene tubing and loadsure elements)
Drive ingress rating IP31, IP66, NEMA 2, NEMA 4X
Drive power supply 100-120 V/200-240 V 1ph 50/60 Hz 250 VA
Compatible tubing bore size

Description

WATSON MARLOW 600 SERIES CASED PUMP

Watson Marlow Fluid Technology Group 630 Series Process Pumps:

630 series process pumps offer four drive options, colour display and intuitive menu structures that provide visual status indication and minimal key presses.

Flow rates from 0.001 L/min (0.0002 USGPM) to 18 L/min (4.76 USGPM) depending on model and pumphead/tubing options.

Pumphead options available as standard:

  • 620R pumphead for continuous tubing
  • 620RE and 620RE4 pumpheads for tube elements
  • 620L and 620LG twin channel low pulse pumpheads

Features and benefits

  • Colour display and intuitive menu structures provide visual status indication and minimal key presses
  • Flow rates from 0.001 L/min (0.0002 USGPM) to 18 L/min (4.76 USGPM) depending on model and pumphead/tubing options
  • 620R, 620RE, 620RE4, 620L and 620LG pumpheads available
  • 2,650:1 speed control range from 0.1 to 265 rpm in 0.1 rpm increments
  • Keypad incorporates 3-level security PIN lock
  • IP31 (NEMA 2) and IP66 (NEMA 4X) cased pumps available
  • Dual voltage, 115 V/230 V 50/60 Hz
  • Remote Analogue/Digital, RS232, RS485, PROFIBUS®, PROFINET®, SCADA and EtherNet/IP™ control options
Drive with 620R Pumphead Drive with 620RE Pumphead Drive with 620RE4 Pumphead Drive with 620L Pumphead Drive with 620LG Pumphead
Pumphead number of rollers 2 2 4
Pumphead number of channels 1 1 1 2 2
Max. flow rate 16 L/min 18 L/min 13 L/min 13.3 L/min 13.3 L/min
Min. flow rate 0.001 L/min 0.004 L/min 0.003 L/min 0.002 L/min 0.002 L/min
Max. flow rate 254 USGPH 301 USGPH 206 USGPH 211 USGPH 211 USGPH
Min. flow rate 0.02 USGPH 0.06 USGPH 0.05 USGPH 0.03 USGPH 0.03 USGPH
Max. flow rate 4.76 USGPM 4.76 USGPM 4.76 USGPM 4.76 USGPM 4.76 USGPM
Min. flow rate 0.0002 USGPM 0.0002 USGPM 0.0002 USGPM 0.0002 USGPM 0.0002 USGPM
Drive speed control ratio 2650:1 2650:1 2650:1 2650:1 2650:1
Drive speed 0.1 – 265 rpm 0.1 – 265 rpm 0.1 – 265 rpm 0.1 – 265 rpm 0.1 – 265 rpm
Operating temperature range 5 to 40 °C 5 to 40 °C 5 to 40 °C 5 to 40 °C 5 to 40 °C
Operating temperature range 41 to 104  °F 41 to 104  °F 41 to 104  °F 41 to 104  °F 41 to 104  °F
Weight 19.6 – 20.5 kg 19.6 – 20.5 kg 20.1 – 21 kg 24.3 – 25.2 kg 24.3 – 25.2 kg
Weight 43.2 – 45.2 lbs 43.2 – 45.2 lbs 44.3 – 46.3 lbs 53.6 – 55.6 lbs 53.6 – 55.6 lbs
Drive weight 16.5, 17.4 kg 16.5, 17.4 kg 16.5, 17.4 kg 16.5, 17.4 kg 16.5, 17.4 kg
Drive weight 36.4, 38.5 lbs 36.4, 38.5 lbs 36.4, 38.5 lbs 36.4, 38.5 lbs 36.4, 38.5 lbs
NEMA module weight 0.9 kg 0.9 kg 0.9 kg 0.9 kg 0.9 kg
NEMA module weight 2 lbs 2 lbs 2 lbs 2 lbs 2 lbs
Control types EtherNet/IP™, Profibus®, Profinet®, Remote Analogue/Digital, RS232, RS485, SCADA EtherNet/IP™, Profibus®, Profinet®, Remote Analogue/Digital, RS232, RS485, SCADA EtherNet/IP™, Profibus®, Profinet®, Remote Analogue/Digital, RS232, RS485, SCADA EtherNet/IP™, Profibus®, Profinet®, Remote Analogue/Digital, RS232, RS485, SCADA EtherNet/IP™, Profibus®, Profinet®, Remote Analogue/Digital, RS232, RS485, SCADA
Drive control options Bp, BpN, Du, DuN, DuS, En, EnN, Pn, PnN, S, SN, U, UN, US Bp, BpN, Du, DuN, DuS, En, EnN, Pn, PnN, S, SN, U, UN, US Bp, BpN, Du, DuN, DuS, En, EnN, Pn, PnN, S, SN, U, UN, US Bp, BpN, Du, DuN, En, EnN, Pn, PnN Bp, BpN, Du, DuN, En, EnN, Pn, PnN
Drive standards CE, cETLus, C-Tick, IRAM, NSF/ANSI 61 (for Marprene tubing and loadsure elements) CE, cETLus, C-Tick, IRAM, NSF/ANSI 61 (for Marprene tubing and loadsure elements) CE, cETLus, C-Tick, IRAM, NSF/ANSI 61 (for Marprene tubing and loadsure elements) CE, cETLus, C-Tick, IRAM, NSF/ANSI 61 (for Marprene tubing and loadsure elements) CE, cETLus, C-Tick, IRAM, NSF/ANSI 61 (for Marprene tubing and loadsure elements)
Drive ingress rating IP31, IP66, NEMA 2, NEMA 4X IP31, IP66, NEMA 2, NEMA 4X IP31, IP66, NEMA 2, NEMA 4X IP31, IP66, NEMA 2, NEMA 4X IP31, IP66, NEMA 2, NEMA 4X
Drive humidity (Non-condensing) 80 % up to 31 °C (88 °F) decreasing linearly to 50 % at 40 °C (104 °F) (Non-condensing) 80 % up to 31 °C (88 °F) decreasing linearly to 50 % at 40 °C (104 °F) (Non-condensing) 80 % up to 31 °C (88 °F) decreasing linearly to 50 % at 40 °C (104 °F) (Non-condensing) 80 % up to 31 °C (88 °F) decreasing linearly to 50 % at 40 °C (104 °F) (Non-condensing) 80 % up to 31 °C (88 °F) decreasing linearly to 50 % at 40 °C (104 °F)
Drive noise <70dB(A) at 1m <70dB(A) at 1m <70dB(A) at 1m <70dB(A) at 1m <70dB(A) at 1m
Max. altitude 2000 2000 2000 2000 2000
Drive power supply 100-120 V/200-240 V 1ph 50/60 Hz 250 VA 100-120 V/200-240 V 1ph 50/60 Hz 250 VA 100-120 V/200-240 V 1ph 50/60 Hz 250 VA 100-120 V/200-240 V 1ph 50/60 Hz 250 VA 100-120 V/200-240 V 1ph 50/60 Hz 250 VA
Compatible tubing bore size 6.4, 9.6, 12.7, 15.9 mm 12, 17 mm 12, 17 mm 8, 12, 16 mm 8, 12, 16 mm

PLEASE CHECK MORE DETAILS: WATSON MARLOW PUMP