TRUMEN Two-Wire Capacitance Type Level Transmitter TLC2
♦ Free flowing homogeneous liquids Like oil, raw water, WFI, DM/DI water etc.
♦ Suitable for mounting on the top.
♦ Maximum process temperature: 200 ºC.
♦ Maximum process pressure is 20 bars.
♦ Able to handle caustic liquids.
Description
TRUMEN Two-Wire Capacitance Type Level Transmitter TLC2
Product Overview-
Trumen two wire capacitance type level transmitter model TLC2 is suitable for liquid & solid application like powder, slurry, chemical, edible oil etc. Trumen TLC2 is a fully, partially PTFE & ceramic insulated and used as a robust rod probe and flexible rope probe for level detection.
Applications-
Capacitance level transmitter probe is used in different applications like
- Oil.
- Water.
- WFI.
- DM/DI water.
- Corrosive liquids.
- Wheat flour..
- Rice paddy.
- Granuels.
- Chemical.
- WTP.
- STP.
- Cement.
- Steel.
- Food & Beverages..
- Diesel.
Features:-
- Compact size.
- Fast response time.
- Compensation against material build-up..
- Easy calibration via DIP switch.
- Suitable for top mounting.
- Fluid Turbulation Stability.
- 4-20mA isolated output or 1-5V & 2-10V output.
- Ingress protection: IP 67/68 (as per IS/IEC 60529:2001).
- Process temperature max 300°C.
- Process pressure max. 20 bar.
- Threaded / Flanged / customized process connections.
- Rigid rod / flexible rope probe version.
- Remote electronics with as standard 2 meters cable length.
Performance Specifications:-
Parameter | Description | ||
General | |||
Min. Dielectric Constant |
1.8 (non-hygroscopic) | ||
Maximum measured error | Max. ±1 mm (at reference operating conditions) | ||
Repeatability | 1 mm | ||
Accuracy | ±1% | ||
Hysteresis | Approx. 2 mm | ||
Influence of medium | Max +2 to -3 mm (-20 to +150 °C) | ||
Influence of medium pressure | Max 0 to -3 mm (-1 to 20 bar) | ||
ICT to TLC cable | Shielded 2 Core PVC cable with 1 to 1.5 mm2 conductors cross-section | ||
Process | |||
Ambient Temperature | -20°C … 70°C (-4°F … 158 °F) | ||
Process Temperature | -20°C … 100°C (-4°F … 212 °F) | ||
Extended Process Temperature
|
PTFE Insulation: -30°C … 250°C (-22 °F … 482 °F), *Ceramic Insulation: -30°C … 300°C (-22°F … 572°F),(extensions & heat sinks required)
(*Note- Ceramic part insulation probe suitable for non-conductive or low dielectric material only) |
||
Process Pressure
|
absolute / max. 20 bar (for ceramic insulation : 1 atm) | ||
Physical Specifications | |||
Wetted Parts
|
SS 304, SS 316, SS 316L, PTFE, Part Ceramic
|
||
Process Connections
|
NPT / BSP 1″, 1-1⁄4″, 1-1⁄2″, 2″ & TC 1-1/2″, 2″ & Flanged ANSI / JIS / DIN / ASA / custom | ||
Probe Insertion Length | Rigid Rod Probe: 50mm to 3,000mm, Flexible Rope Probe: 100mm to 20,000mm |
DATA SHEET –PDF