SIEMENS Simatic S7-200 Smart PLC is made to specifically meet the needs of emerging markets that are always being squeezed by costs and demands for consistent performance. When paired with other Siemens Smart drive solutions, the Simatic S7-200Smart, which offers a great performance-to-price ratio, aids in creating a highly affordable yet effective automation solution.

Description

SIEMENS Simatic S7-200 PLC

SIEMENS Simatic S7-200 PLC

Product Highlights:-
It provides CPU modules that have a large number of I/O points onboard (up to 60 points.)The CPU module has a standard type and a compact type for the users to choose from,
which can meet the different needs of customers.

Extension options, accurate customization-
The new signal boards are designed with scalable communication ports, digital or analog channels, that are closely fitting to the user’s application requirements, and lower the user’s costs for expansion.

High-speed chip, excellent performance-
It is equipped with Siemens dedicated processor chip, the basic instruction execution time is up to 0.15 μs, it has the leading performance compared to the micro PLC of the same level, and it can easily deal with complex and fast processes.

Ethernet interconnectivity is economical and convenient-

The standard Ethernet interface of the CPU supports various industrial Ethernet communication protocols such as PROFINET, TCP, UDP, and Modbus TCP. Through this interface, it can also communicate with other PLCs, touch screens, inverters, servo drives, host computers, and so on. The program can be downloaded to the PLC using a common network cable, eliminating the need for a dedicated Programming cable, it is economical and fast.

Technical specifications

Technical specification for CPU SR20/ST20

Model CPU SR20 AC/DC/RLY CPU ST20 DC/DC/DC
Order No.: (MLFB) 6ES7 288-1SR20-0AA0 6ES7 288-1ST20-0AA0
Standard
Dimension W x H x D (mm) 90 x 100 x 81
Weight 367.3 g 320 g
Power consumption 14 W 20W
Available current (EM bus) Max. 740 mA (5 V DC) Max. 1110 mA (5 V DC)
Available current (24 V DC) Max. 300 mA (sensor power source)
Digital input current consumption (24 V DC) 4mA for each input point used
CPU features
User memory 12 KB program memory /8 KB data memory /max. 10 KB retentive memory
Onboard digital I/O
Process image size 256 bits input (I) / 256 bits output (Q)
Analog image 56 words input (AI) / 56 words output (AQ)
Bit memory (M) 256 bits
Temporary (local) memory The main program has 64 bytes, each subroutine and interrupt program has 64 bytes
I/O module extension 6 extension modules
Signal board extension Max. 1 signal board
High-speed counters 4 in total
Single phase: 4 of 200 kHz
Quadrature phase: 2 of 100 kHz
Pulse output 2 of 100 kHz
Pulse capture input 12
Cycle interrupt 2 in total, the resolution is of 1ms,
Interrupt Edge 4 rising edges and 4 falling edges (when using optional signal board, there are 6 edges each)
Memory Micro SDHC card (optional)
The precision of the real-time clock
Real-time clock hold time In general 7 days, or min. 6 days when 25 °C (Maintenance free super capacitor)
Performance/ Processing Time
Boolean 0.15 μs/instruction
Moving word operations 1.2 μs/instruction
Real mathematical operations 3.6 μs/instruction
The user’s program elements supported by the S7-200 SMART
POUs type/quantity

• main program: 1

• sub-program: 128 (0 to 127)

• interrupt program: 128 (0 to 127)

Nesting depth

• from the main program: 8 sub-program level

• from interrupt program: 4 sub-program level

Accumulators 4
Timer type/quantity

• non-holding (or not retained) (TON, TOF): 192

• holding (or retained) (TONR): 64

Counters 256
Communications
Number of ports 1 Ethernet port/ 1 serial (RS485) /1 additional serial (optional RS232/485 signal board) port
HMI equipment max. 4 connection on serial port

max. 8 connections on ethernet port

Programming equipment (PG)
Several connections Ethernet:

• 8 for HMI

• 1 for programming

• 8 for CPU

• 8 for active GET/PUT connection

• 8 for passive GET/PUT connection

serial (RS485) :

• each port has 4 for HMI connections

Data transmission rate Ethernet: 10/100 Mb/s

RS485 system protocol: 9600, 19200 and 187500 b/s

RS485 free port: 1200 to 115200 b/s

Isolation (external signal and PLC logic side) Ethernet: Transformer isolation, 1500 V AC

RS485: none

Type of cable ethernet t: CAT5e shielded cable

RS485: PROFIBUS network cable

Power source
Voltage range 85 ~ 264 V AC 20.4 ~ 28.8 V DC
Power supply frequency 47 ~ 63 Hz

 

Model (continued) CPU SR20 AC/DC/RLY CPU ST20 DC/DC/DC
Input current When the maximum load is reached, only CPU is included

210 mA when the voltage is 120 V AC (with a 300 mA sensor power output)

90 mA when voltage is 120 V AC (without a 300 mA sensor power output)

120 mA when voltage is 240 V AC (with a 300 mA sensor power output)

60 mA when the voltage is 240 V AC (without a 300 mA sensor power output)

When the max load is reached, it CPU and all the scalable extensions are included

290 mA when the voltage is 120 V AC

170 mA when voltage is 240 V AC

When the maximum load is reached, only CPU is included

160 mA when the voltage is 24 V DC (without a 300 mA

sensor power output)

430 mA when the voltage is 24 V DC (with a 300 mA sensor

power output)

When the max load is reached, CPU and all the scalable

extensions are included

720 mA when voltage is 24 V DC

Inrush current (max) 9.3 A when voltage is 264 V AC 11.7 A when voltage is 28.8 DC
Isolation (input power with the logic side) 1500 V AC
Leakage current, AC line for functional earthing Max 0. 5 mA
Hold time (power off) 30 ms when voltage is 120 V AC

200 ms when voltage is 240 V AC

20 ms when voltage is 24 V DC
Internal fuse (cannot be replaced by the user) 3 A, 250 V, Slow-blow fuse 3 A, 250 V, Slow-blow fuse
Sensor power source
Voltage range 20.4 ~ 28.8 V DC
Rated output current (max) 300 mA (short circuit protection)
Maximum ripple noise (<10 MHz) <1 V peak-peak value
Isolation (CPU logic side and sensor power source) Not isolated
Digital input
Number of input points 12
Type The sinking / sourcing type (IEC type 1 sinking) The sinking/sourcing type (IEC type 1 sinking excluding

I0.0 to I0.3)

Rated voltage It is 24V DC when the current is 4 mA, nominal value
Allowable continuous voltage max x 30 V DC
Surge voltage 35 V DC, lasting 0.5 s
Logic 1 signal (min) It is 15 V DC when the current is 2.5 mA The voltage is 4 V DC when it ranges from I0.0 to I0.3,

I0.6 to I0.7: 8 mA

Other input: 15 V DC when it is 2.5 mA

Logic 0 signal (min) It is 5 V DC when the current is 1 mA The voltage is 1 V DC when it ranges from I0.0 to I0.3,

I0.6 to I0.7: 1 mA

Other input: 5 V DC when it is 1 mA.

Isolation (field side and logic side) 500 V AC, lasting 1 min
Isolation group 1
Filter time Each channel can be separately selected (point I0.0 to 11.3) :

0.2, 0.4, 0.8, 1.6, 3.2, 6.4 and 12.8 μs

0.2, 0.4, 0.8, 1.6, 3.2, 6.4 and 12.8 ms

HSC clock input frequency (max)

(Logic 1 battery = 15 ~ 26 V DC)

Single phase: 4 of 200 kHz

Quadrature phase: 2 of 100 kHz

Number of inputs that connect at the same time 12
Cable length (max), its unit is meter shielded d: 500m (normal input), 50m (HSC input) ;

non shielded: 300m (normal input)

I0.0 to I0.3, shielded (only limited to this category) :

500 m (normal input), 50 m (HSC input)

I0.6 to I0.7, shielded (only limited to this category) :

500 m (normal input),

All other inputs: shielded: 500 m (normal input) ;

non shielded: 300 m (normal input)

Digital output
Number of output 8
Type Relay, dry contact solid d state-MOSFET (source-type)
Voltage range 5 ~ 30 V DC or 5 ~ 250 V AC 20.4 ~ 28.8 V DC
Logic 1 signal when the current is max. Min. 20 V DC
Logic 0 signal when the load is KG Max. 0.1 V DC
Rated current at each point (max) 2.0 A 0.5 A
Rated current at each public end (max) 10.0 A 6 A
Lamp load 30 W DC/200 W AC 5 W
On state resistance w equipment is 0.2 Ω maximally Max. 0.6 Ω
Leakage current at each point Max. 10 μ A
Surge current t is 7A when the contact is closed 8 A, max. lasting 100 ms
Overload protection none
Isolation (field side and logic side) 1500 V AC, lasting 1 min (coil and contact) none, (coil and logic side) 500 V AC, lasting 1 min
Isolation resistance New equipment is 100 MΩ minimally
Disconnect the insulation between the contacts 750 V AC, lasting 1 min
Isolated group 1 2
Inductive voltage clamp Not recommended L+ – 48 V DC, 1 W loss
Relay max. on/off frequency Not recommended
Switching delay (Qa.0-Qa.3) Max. 10MS from m the disconnection to connection max.1 μs

from the connection to disconnection is 3 μs max.

Switching delay (Qa.0-Qa.7) Max. 10 ms From the disconnection to connection max. 50 μs

from the connection to disconnection is 200 μs max.

Mechanical life (no load) 10,000,000 break/close cycles
Contact life under the rated load 100,000 break/close cycles
Output state under the STOP mode Last value or replicable value (The default value is 0)
Number of outputs that are connected at the same

time

8
Cable length Shielded: 500 m; nonshielded: 300 m

MORE INFORMATION:-CATALOGUE

Additional information

Product Model

Simatic S7-200

Brand

Siemens