SICK GAS TRANSMITTERS TRANSIC100LP

Add to Wishlist
Add to Wishlist

Measuring the oxygen in the process can be quite simple. The TRANSIC100LP from SICK is the rugged transmitter that uses Tunable Diode Laser Spectroscopy (TDLS) to measure O2 reliably. A technology more common in the world of high-tech analysis is now being used in a field instrument: at an attractive price, easy installation, a long life, low maintenance, and suitable for use in potentially explosive atmospheres.

Description

SICK GAS TRANSMITTERS TRANSIC100LP

A good nose for oxygen

♦ Simple-
The TRANSIC100LP is a SICK GAS TRANSMITTER that measures in-situ or “inline”. The sensor is designed as a measuring probe. This ensures that the lens system in the transmitter is always optimally aligned and installation is very simple. The measuring task can be implemented with little need for additional technical aids. Costly sampling and gas conditioning can be omitted in many cases.

♦ Fast-
For the operation of the system, it is decisive to always have the relevant process parameters in view. Direct measurement in the process is characterized by an extremely low response time.

Consistent-
The TRANSIC100LP is the consistent implementation of a gas analyzer in the form of a field device: it combines the
advantages of oxygen laser spectroscopy with the easy handling of a transmitter.

♦ Low maintenance-
The TRANSIC100LP is based on the measurement principle of Tunable Diode Laser Spectroscopy (TDLS) and is a purely
optical sensor. The TRANSIC100LP measures a natural characteristic of the oxygen directly independent of location
and time. The measurement is virtually free of temporary drift. The gas transmitter has no mechanical components and
is wear-free. Omitting sampling and gas conditioning means no operating or maintenance costs occur. SICK recommends
calibration intervals of 12 months. Measurement runs at all times without using any consumables.

SICK GAS TRANSMITTERS TRANSIC100LP

Technical overview

Measured values O2
Measurement principles Diode laser spectroscopy (TDLS)
Measuring ranges
O2 0 … 5 Vol.-% / 0 … 100 Vol.-%
Response time (t90)
≤ 10 s
Accuracy
≤ 0.2 Vol.-%
Zero point drift
± 0.1 Vol.-%: per year
Process temperature
–20 °C … +80 °C
Process pressure
800 hPa … 1,400 hPa
Ambient temperature
–20 °C … +60 °C
Storage temperature
–30 °C … +80 °C
Ex-approvals
IECEx Sender/receiver unit: Ex op is / ib IIB T4 Ga/Gb; Ex ib tb op is IIIC T85°C Db
TSA151 connecting unit: Ex eb mb [ib] IIB T4 Gb; Ex tb [ib] IIIC T85°C Db
ATEX Sender/receiver unit: II 1/2 G Ex op is / ib IIB T4 Ga/Gb; II 2 D Ex ib tb op is IIIC T85°C Db
TSA151 connecting unit: II 2 G Ex eb mb [ib] IIB T4 Gb; II 2 D Ex tb [ib] IIIC T85°C Db
NEC/CEC (US/CA) Sender/receiver unit: Class I, Division 2, Group A, B, C and D; T4 Ta=-20°C to +60°C; IP66
Measuring probe: Class I, Division 1, Group A, B, C and D; T4 Ta= –20°C to +80°C; IP66
Electrical safety CE, FM
Enclosure rating
IP66
Analog outputs 1 output active:
0/4 … 20 mA, 500 Ω1 output active:
0/4 … 20 mA, 200 Ω
Only for ATEX/IECEx version TRANSIC151LP
Digital outputs 1 relay contact:
30 V AC, 1 A / 60 V DC, 0.5 A1 NAMUR output:
Only for ATEX/IECEx version TRANSIC151LP
Serial ✔ , ✔
Remark Not for the ATEX/IECEx version
Type of fieldbus integration RS-232
RS-485
Function Proprietary service interface
USB
Remark Not approved for Ex-applications
Function Proprietary service interface
Dimensions (W x H x D)
Dimensions may vary. For details, see the dimensional drawings.
Weight
2.2 kg
Material in contact with media Stainless steel 1.4404 (AISI 316L), Kalrez®, EPDM, PTFE, SiN, MgF2, polymer coating
Mounting Flange for direct installation in the process

Wall-mounting bracket for ambient air measurement

Wall-mounting bracket for measurement with measuring gas cell

Power supply
Voltage 24 V DC, ± 10 %
TRANSIC151LP 21.6 V DC … 26.4 V DC, ± 10 %
Voltage For ATEX/IECEx version via TSA151 connecting unit, a PELV power supply is mandatory
Current consumption ≤ 500 mA
Power consumption ≤ 6 W
TRANSIC151LP: ≤ 5.2 W
Corrective functions Adjustment with ambient air or test gases
Test functions Contamination check

 

 

Additional information

Product Model

TRANSIC100LP