- Functional principle: Through-beam sensor
- Fork opening: 5 mm
- Connection type: Connector, M8x1-Male, 3-pin
- Switching output: PNP
- Output function: NO/NC
- Light type: LED, red light
For Price Call: 01329727092
Email: sales@voltecbd.com
- Functional principle: Through-beam sensor
- Fork opening: 180 mm
- Connection type: Connector, M8x1-Male, 3-pin
- Switching output: PNP
- Output function: NO/NC
For Price Call: 01329727092
Email: sales@voltecbd.com
- Functional principle: Through-beam sensor
- Fork opening: 30 mm
- Connection type: Connector, M8x1-Male, 3-pin
- Switching output: PNP/NPN
- Output function: NO/NC
For Price Call: 01329727092
Email: sales@voltecbd.com
- Sensing range (max.): 1 – 20 mm
- Connection type: Cable, 3.00 m, PUR
- Switching output: PNP/NPN
- Output function: NO/NC programmable
- Switching frequency: 100 Hz
- Installation type: Flush
For Price Call: 01329727092
Email: sales@voltecbd.com
- Sensing range (max.): 1 – 4 mm
- Connection type: Connector, M12x1-Male, 3-pin
- Switching output: NPN
- Output function: NO
- Switching frequency: 100 Hz
- Installation type: Flush
For Price Call: 01329727092
Email: sales@voltecbd.com
- Sensing range (max.): 1 - 20 mm
- Connection type: Connector, M12x1-Male, 4-pin
- Switching output: PNP
- Output function: NO/NC programmable
- Switching frequency: 100 Hz
- Installation type: Flush
For Price Call: 01329727092
Email: sales@voltecbd.com
- Sensing range: 2 mm
- Connection type: Cable with connector, M8x1-Male, 3-pin, 0.30 m, PUR
- Switching output: PNP
- Output function: NC
- Switching frequency: 5000 Hz
- Installation type: Flush
For Price Call: 01329727092
Email: sales@voltecbd.com
- Sensing range: 4 mm
- Connection type: Connector, M12x1-Male, 3-pin
- Switching output: PNP
- Output function: NO
- Switching frequency: 350 Hz
- Installation type: Flush
For Price Call: 01329727092
Email: sales@voltecbd.com
- Series : 50K
- Dimension : 28.5 x 80.5 x 62 mm
- Interface : PNP normally open (NO) PNP normally closed (NC)
- Principle of operation : Photoelectric sensor
- Principle of optical operation : Diffuse sensor, triangulation
Pressure-rated inductive sensors
- Pressure-rated up to 500 bar
- High temperature-rated up to 120 °C
- Appropriate for use in explosion-protected areas
- Overall dimensions from M5 to M18
- Short and long configurations
- With and without fixed stop
Inductive standard sensors:
- Cylindrical sensors in designs from M5 to M30 and various cuboid configuration
- Variants for DC-3/4 wire, IO-Link and DC, AC and AC/DC 2 wire
- Shielded and unshielded versions
- Flush variants with ranges of up to 15 mm
- Non-flush variants with ranges of up to 30 mm
- Plug or cable connection
The GWA-250-U0 dual limit value switch enables the parallel configuration of up to two switching
levels for continuous measurements without the installation of extra measurement equipment.
♦ The key coding switch allows for the simplest switching point change.
♦ Switchable input.
♦ Powering integrated converters.
Read more
Galvanic isolation, universal signal converter, and standard signal conversion.
♦ Installing is simple.
♦ Power supply that is universal.
♦ 3x isolated galvanic.
Read more
Pipe installation data logger with GSM data transmission, powered by a battery or an AC adapter.
♦ Installing in a 2" tube.
♦ Safety overflow.
♦ Using the most effective source for communication.
Read more
Hydrostatic level measurement using a level sensor with a 22mm diameter and a capacitive ceramic measuring cell
with an RS485 Modbus-RTU output signal.
♦ Reliable and efficient ceramic cell.
♦ Possible integrated temperature measurement.
♦ Low consumption of energy.
Read more
Independent data logger and IOT Gateway
♦Power supply options come in a variety of forms. ♦Using the most effective source for communication. ♦with up to 7 sensors and 12 measurement types.VU 570 - Vortex ultrasonic sensor for flow measurement
Independent of the gas composition, flow meters for technical gases and mixed gases.The VU 570 helps you keep an eye on, control, and minimize your usage while
improving sustainability. One sensor can be used to track your consumption
of various gas compositions and gas types.
FA 500 - Dew point sensor with integrated display and alarm relay
- Dew point sensor FA 500 from -80 to 20°Ctd.
- For refrigeration, membrane, and desiccant dryers, the FA 500 is the perfect dew point sensor with an integrated display and warning relay.
FA 550 - Dew point sensor in robust die-cast aluminum housing
✓Robust dew point sensor for gases and compressed air
✓ The Dew point FA 550 is perfectly suited for measuring dew points outside and reliably does so even in punishing industrial settings.
✓Dew point measurement after adsorption dryers, membrane dryers, or refrigeration dryer in compressed air systems.
Read more
Pressure transmitter/pressure switch for typical applications with data memory Monitoring of gases, vapors, liquids, and dust at absolute or relative pressures.
With ceramic front-flush or internal diaphragm
With TFT-display, 4-20mA or 0-10V output and up to 4 pnp switching outputs.
♦ Color display and full text programming.
♦ Ceramic cell that is precise and stable.
♦ 500 000 measuring point data logger.
Read more
Ultrasonic flowmeter
✓ Suitable for use with both conductive and non-conductive liquids. ✓ Due to the seal-free sensor, there is high process safety. ✓ The measurement tube can move easily.MODEL:-F630
Magnetic inductive flowmeter, small or separate ✓ The suitable device for every application, with a wide range of options. ✓ Possible spared variation. ✓ ATEX-Authorization. ✓ Applications for hygiene. ✓ Mechanism for detecting errors.Multivariable, simple, and user-friendly smart magmeter for utilities
♦ Decent design.
♦ Enclosed control panel.
♦ Parameterization is possible via Bluetooth.
Flow switch and transmitter for basic industrial, sanitary, and aseptic applications.
♦ Applications for hygiene.
♦ Compact design.
♦ Speed of response.
Read more
♦ Installing a simple pressurized system is possible.
♦ High precision.
♦ Very little pressure drop.
Read more
♦ Quick response.
♦ Operator comfort is improved through display and operation on-site.
♦ Wireless.
Read more
♦Comprising a measurement portion, compressed air, and gas meter.
♦ Simple and affordable installation.
♦ Owing to its excellent accuracy, it is suitable for measuring leaks.
Read more
In order to avoid the pricey installation of two or more separate devices, the Rosemount 8800 MultiVariable Vortex Flow Meter integrates temperature and flow sensors into a single, extremely precise instrument. The integrated, detachable temperature sensor, which is isolated from the process and distinct from the Vortex flow sensor, delivers a precise process temperature measurement. It also offers temperature and pressure compensation, providing compensated mass flow and corrected volume in steam and liquid applications when the input comes from an external HART® pressure transmitter.