Need help? Call us: 01326 708334, 01326 708335 or info@voltecbd.com
Electrical data:
Connection terminals: 0.14 ÷ 2.5 mm2 (AWG 26 ÷ 14)
Cable entry:Cable gland: M20x1.5 with cable sheath diameter 6÷12mm CONDUIT: NPTx½ o NPT3/4
Output activation delay: Rods free → Rods covered: c.a. 1 sec Rods covered → Rods free c.a. 1... 2 sec
Detection fuctions FSH/FSL: Settable on the circuit with selector switch
Vibration frequency: [Hz] 200 c.a.
Over voltage category: II
Pollution degree: 2 (inside housing)
Operative Conditions:
Ambient temperature: [°C] -40 ÷ +60
Process temperature-Tc: [°C] -40 ÷ +150
Ventilation:Ventilation is not required
Min. powder density: [g/l] Setting A : c.a. 150 - Setting B : c.a. 30
Features of bulk material: No strong tendency to cake or deposit. Max grain size 8 mm
Max. mechanical load: [N] 500 laterally on vibrant rods
Max. process pressure: [Bar] 16
Vibration: c.a. 200
Relative humidity: 0 ÷ 100%, suitable for outdoor use
Altitude: [m] max 2.000
Read more
Measuring the oxygen in the process can be quite simple. The TRANSIC100LP from SICK is the rugged transmitter that uses Tunable Diode Laser Spectroscopy (TDLS) to measure O2 reliably. A technology more common in the world of high-tech analysis is now being used in a field instrument: at an attractive price, easy installation, a long life, low maintenance, and suitable for use in potentially explosive atmospheres.
Read more

Voltec Engineering Limited
Automation and control products are the focus of VOLTEC ENGINEERING LIMITED. In the area of comprehensive industry solutions for alteration, upgrading, and new construction projects, VOLTEC ENGINEERING LIMITED is a one-stop solution provider.
Need Help?
01326 708335
01329 727092
Customer Service
© 2023 Voltec Engineering Ltd. | Design & Developed by mPair Technologies Ltd.