Need help? Call us: 01326 708334, 01326 708335 or info@voltecbd.com
- input specification type 1/3
- no bouncing due to mechanical switches thanks to 3 ms input filter
- tool-free connection by direct plug-in technology for solid wire conductors
- space-saving use in the control cabinet
- direct connection of multi-channel sensors in 1-wire connection technology in the smallest space
- increased packing density with 16 connection points in the housing of a 12 mm terminal bloc
φ50 Incremental Type
Read more
- Long service-life with a φ50 mm miniature case and φ8 mm- thick shaft.
- Realizes 1,024 pulses with a metal slit board that resists vibrations and impacts.
- Wide power range of 4.75 to 30 V DC.
- Totem-pole output suitable for cable extension.
Electrical data:
Connection terminals: 0.14 ÷ 2.5 mm2 (AWG 26 ÷ 14)
Cable entry:Cable gland: M20x1.5 with cable sheath diameter 6÷12mm CONDUIT: NPTx½ o NPT3/4
Output activation delay: Rods free → Rods covered: c.a. 1 sec Rods covered → Rods free c.a. 1... 2 sec
Detection fuctions FSH/FSL: Settable on the circuit with selector switch
Vibration frequency: [Hz] 200 c.a.
Over voltage category: II
Pollution degree: 2 (inside housing)
Operative Conditions:
Ambient temperature: [°C] -40 ÷ +60
Process temperature-Tc: [°C] -40 ÷ +150
Ventilation:Ventilation is not required
Min. powder density: [g/l] Setting A : c.a. 150 - Setting B : c.a. 30
Features of bulk material: No strong tendency to cake or deposit. Max grain size 8 mm
Max. mechanical load: [N] 500 laterally on vibrant rods
Max. process pressure: [Bar] 16
Vibration: c.a. 200
Relative humidity: 0 ÷ 100%, suitable for outdoor use
Altitude: [m] max 2.000
Read more
The GWA-250-U0 dual limit value switch enables the parallel configuration of up to two switching
levels for continuous measurements without the installation of extra measurement equipment.
♦ The key coding switch allows for the simplest switching point change.
♦ Switchable input.
♦ Powering integrated converters.
Read more
The EK1100 EtherCAT Coupler is the link between the EtherCAT protocol at the fieldbus level and the EtherCAT Terminals. The coupler converts the passing telegrams from Ethernet 100BASE-TX to E-bus signal representation. A station consists of a coupler and any number of EtherCAT Terminals that are automatically detected and individually displayed in the process image.
Read more
Voltec Engineering Limited
Automation and control products are the focus of VOLTEC ENGINEERING LIMITED. In the area of comprehensive industry solutions for alteration, upgrading, and new construction projects, VOLTEC ENGINEERING LIMITED is a one-stop solution provider.
© 2025 Voltec Engineering Ltd. | Design & Developed by mPair Technologies Ltd.